BLACK GRAY THERMISTOR BLACK GRAY CIRC UI T D IA GR A M ( PIPE TEMP. ) BLACK THERMISTOR BLACK ( ROOM TEMP. ) INDOOR UNIT OUTDOOR UNIT HIGH PRESSURE SWITCH CN90 STEP MOTOR INDICATOR PCB ASSY CONTROLLER PCB ASSY BROWN BROWN THERMISTOR ( COMPRESSOR TEMP.
IN DOOR PC B C IRCUI T DIAG RAM THERMISTOR ( ROOM TEMP. ) CN8-1 BLACK CONTROL UNIT B02B-XASK-1-A BLACK CN8-2 WHITE CN2-1 ABYA30LBT : EZ-00712HSE CN2-2 CN7-1 CN2-3 B02B-XAYK-1-A B5P-SHF-1AA CN7-2 CN2-4 WHITE YELLOW ABYA36LBT : EZ-00713HSE CN2-5 THERMISTOR ( PIPE - M I D. TEMP. )
Page 10
INDOOR UNIT INDICATOR PCB ASSEMBLY K04GN-0700HSE-D0 R201 - R203 330 <1/4W> x 3 D205 EMPG3863X D206 EMAA3863X TO MAIN PCB OPERATION BROWN D207 EBR3864X TIMER LOUVER ORANGE LOUVER YELLOW WHITE REMOTE SIGNAL BLUE SW201 PURPLE C202 C201 EVQPAG04K MANUAL AUTO SWITCH GRAY...
OUT DO OR PC B C IR CU I T DIA GR AM INVERTER ASSEMBLY AOYA30LFTL : EZ-0099HUE TRANSISTOR PCB ASSEMBLY ( I. P. M. ) AOYA36LFTL : EZ-009BHUE AOYA30LFTL : K07BT-0901HUE-TR0 UL1015 AOYA36LFTL : K07BT-0900HUE-TR0 AWG14 WHITE EMI FILTER UL1015 UL1015 POWER SOURCE...
Page 12
OUTDOOR UNIT INVERTER PCB ASSEMBLY AOYA30LFTL : K07BS-0904HUE-C1 CN200 AOYA36LFTL : K07BS-090AHUE-C1 1-1747052-2 G I C7.92-2P TP00351-31 x 2 FH200 FH201 1SS355 DC VOLT I N R601 F201 1.0k R603 FSL 250V 3.15A ( EM ) I C5 <1/10W> 150k 2200p 220/ CT600...
Page 13
OUTDOOR UNIT TRANSISTOR PCB ASSEMBLY ( IPM PCB ) AOYA30LFTL : K07BT-0901HUE-TR0 AOYA36LFTL : K07BT-0900HUE-TR0 TM101 ORANGE C161 TM102 BROWN D100 BLACK LL25XB60 CN303 1971032-5 WHITE I C70-2 BA2903F-E2 W306 I P M-GND WHITE TM301 YELLOW R284, R285, R302 0.04 <5W>...
Page 14
OUTDOOR UNIT AOYA30LFTL POWER SUPPLY PCB ASSEMBLY PTC THERMISTOR K05CW-0901HUE-FL0 R101 CT OUT ZPR0RCH400 VA100 BLACK 470V GRAY C104, C105 0.022 VA101 470V C101 BLACK L102 ORANGE 0.033 N200500K1D7C C100 C103 C106 C108 K101 C102 DW12D1 ...
Page 15
OUTDOOR UNIT AOYA30LFTL CAPACITOR PCB ASSEMBLY K05FB-0901HUE-P0 WHITE YELLOW R200 C201 C203 220k 660/ 660/ <2W> 450V 450V BLUE VIOLET POWER_G AOYA36LFTL CAPACITOR PCB ASSEMBLY K05FB-0900HUE-P0 WHITE YELLOW C200 - C202 660/ 450V BLUE VIOLET POWER_G www.enindel.com 2010.01.15...
E R RO R DET ECTI ON INDOOR UNIT (Troubleshooting with the indoor display) Troubleshooting at the display is possible either on the wired or wireless remote control. FILTER lamp (Red) TIMER lamp (Orange) OPERATION lamp (Green) The OPERATION, TIMER and FILTER lamps operate according to the following error contents.
TROUBLESHOOTING AT REMOTE CONTROL LCD You will find this on the wired remote control LCD. (option) If an error occurs, the following display will be shown. ("EE" will appear in the set room temperature display.) If "CO" appears in the unit number display, there is a remote control error. Refer to the installation instruction sheet included with the remote control.
Page 18
OUTDOOR UNIT SPECIAL INSTALLATION SETTING CAUTION Always turn on the power 12 hours prior to the start of the PUMP DOWN (Refrigerant collecting operation) operation in order to ensure compressor protection Perform the following procedures to collect the refrigerant when moving the indoor unit or the outdoor unit.
PARTS INDOOR UNIT Ref. Description Part number Kit (Base Sub Assy) 9371360010 Panel Left Sub Assy 9360427014 Kit (Panel Right Assy) 9371361017 Cover (Top) 9359737001 Intake Grille 9359738008 Air Filter 9359739005 Filter Guide R 9359692003 Filter Guide L 9359693000 Front Panel 9359734000 Indicator PCB Assy 9705891043...
Page 20
INDOOR UNIT Drain pan Flap Description Part number Ref. 2 Panel Left Sub Assy 9360427014 3 Kit (Panel Right Assy) 9371361017 21 Evaporator Assy 9372585078 22 Distributor Assy 9371325378 23 Coupling Pipe Assy 9373038405 24 Kit (Panel pipe-L) Sub Assy 9371362014 25 Kit (Panel pipe-R) Sub Assy 9371363011...
Page 21
INDOOR UNIT Louver Base Sub Assy Ref. Description Part number Louver Base Sub Assy 9360432025 Louver 9359719007 Rod (Motor) 9359723004 Louver Link 9359726005 Louver Base 9359718000 Louver Spring 9359720003 Louver Stopper 9359724001 Louver Rod 9359725008 Step Motor H 9900297015 Louver Insulation R 9359721000 Louver Insulation L 9359722007...
Page 22
INDOOR UNIT Fan motor Ref. Description Part number Motor Mount 9377999016 Fan Motor Assy 9602389018 Motor Band A assy 9374647019 Motor Band B 9374648023 Reinforcement Motor Band 9378000018 Rubber 9385102002 Casing 9359704003 Kit (Cover Casing) Sub Assy 9371367019 Sirocco Fan Assy 9359701002 Joint Assy 9378038011...
Page 23
Ref. Description Part number INDOOR UNIT Control Box Assy 9377912015 Control unit Control Box A 9359712008 Control Box B 9359713005 Controller PCB Assy (30LBT) 9707393279 Controller PCB Assy (36LBT) 9707393286 Power Supply PCB Assy 9707398076 Terminal 3P 9703345012 Terminal 3P 9306489045 Reactor Assy 9707457018...
PARTS OUTDOOR UNIT Ref. Description Part number Top Panel Sub Assy 9374417032 Front Panel 9374094066 Fan Guard 9374330010 Grip Side 9374173013 Service Panel Sub Assy 9374415052 Right Panel Sub Assy 9374416127 Emblem Rear 9351355005 Valve Cover 9374174010 Protective Net 9375381011 Fan Guard Cover 9378111011 www.enindel.com...
Page 25
OUTDOOR UNIT Ref. Description Part number Base Assy 9374166138 Condenser A Assy 9374433056 Separate Wall Sub Assy 9374413188 Fan Motor 9602843015 Propeller Fan Assy 9366378020 Motor Bracket Sub Assy 9374418152 Valve Plate 9374099030 www.enindel.com 2010.01.15...
ACCE SS OR I E S INDOOR UNIT Name and Shape Q'ty Application Part number Drain hose Adhesive type 70 x 230 9360464002 insulation VT wire For fixing the drain hose 313806350303 L 280 mm Coupler heat insulator For indoor side pipe joint (large) 9378173569 (large pipe)