Shape The Indoor Side Tubing; Wiring Instructions - Sanyo KHS0951 Installation Instructions Manual

Split system air conditioner
Hide thumbs Also See for KHS0951:
Table of Contents

3-5. Shape the Indoor Side Tubing

1) Arrangement of tubing by directions
a) Right or left tubing
Cut out the corner of the right/left frame with a
hacksaw or the like. (Figs. 20 and 21)
b) Right-rear or left-rear tubing
In this case, the corner of the frame need not be
cut.
2) To mount the indoor unit on the rear panel:
Hang the 2 mounting slots of the unit on the
upper tabs of the rear panel. (Fig. 22)

3-6. Wiring Instructions

General precautions on wiring
1) Before wiring, confirm the rated voltage of the unit
as shown on its nameplate, then carry out the
wiring closely following the wiring diagram.
2) Provide a power outlet to be used exclusively for
each unit, with a power supply disconnect and cir-
cuit breaker for overcurrent protection provided in
the exclusive line.
3) To prevent possible hazard due to insulation failure,
the unit must be grounded.
4) Each wiring connection must be done tightly and in
accordance with the wiring system diagram. Wrong
wiring may cause the unit to misoperate or become
damaged.
5) Do not allow wiring to touch the refrigerant tubing,
compressor, or any moving parts of the fan.
6) Unauthorized changes in the internal wiring can be
very dangerous. The manufacturer will accept no
responsibility for any damage or misoperation that
occurs as a result of such unauthorized changes.
Frame
Left tubing
outlet
9
Fig. 20
Frame
Right tubing
outlet
Fig. 21
Fig. 22