W8735D Telephone Access Module
APPLICATION
The W8735D Telephone Access Module (TAM) provides
remote telephone access to the HVAC system when used with
an EnviraCOM™ enabled thermostat such as the
TH9421C1004 VisionPRO IAQ Total Home Comfort System,
and the TH5320C1002 FocusPRO and T8635L1013
Chronotherm™ thermostat. These thermostats are used with
one or more of the following controls: a W8835A EnviraZone
panel, a THM5421C1008, W8635A and B Equipment
Interface Modules, or W8703 Damper Interface Modules. See
the product data sheets for these thermostats to see with
which devices each model would be used. The W8735D also
communicates with R7184P and U oil primary controls and
L7224U Aquastat ®, remote temperature sensors as well as
any other EnviraCOM enabled controls to communicate
current status and alert information.
The user can dial into the TAM and hear local temperatures
and system settings. The user defines the temperature and
a
humidity
limits and their alert priorities to best meet their
monitoring needs.
The W8735D provides remote telephone access for up to four
EnviraCOM independent channels. See Table 1 on page 2 for
the channels and zones available with each model. The
W8735D can be programmed to alert the homeowner and/or
an optional service contractor of abnormal conditions or
lockouts. Up to three different dial-out numbers (main,
backup, and contractor) can be entered in order to insure
alerts are well communicated.
a
Humidity is available only when used with the TH9421C1004
VisionPRO IAQ Total Home Comfort System.
INSTALLATION INSTRUCTIONS
Auxiliary input contacts allow integration of dry contact 24 Vac/
Vdc sensors to interface with the W8735D. In addition to
EnviraCOM thermostats, temperature alerts can be generated
using standard 24 VAC thermostats when interfacing with the
Auxiliary inputs. Auxiliary output contacts allow local
annunciation of alert conditions. Battery back-up enables the
W8735D to let the homeowner know the power is out at the
monitored location (optional 9V battery not included).
The W8735D can share a telephone line with most answering
machines and voice mail systems. The W8735D can be
prompted to pick up a call to gain access to the HVAC system
before the answering machine or voice mail are enabled.
Additionally, he W8735D is equipped with an emergency
telephone line disconnect feature activated when another
receiver in the premise is picked up while the W8735D is
connected. Full access to the W8735D is given when the
complete pass code is entered when prompted. Limited
access is given to contractors when the last five digits of the
programmed contractor telephone number is entered as the
pass code. Contractor access is limited to the W8735D Alert
History.
WARNING
Not a life safety or monitoring device.
The W8735D is not designed for use as a life safety
monitoring device to detect and generate alarms
based on the presence of toxic gases, smoke or fire
within residential homes or commercial buildings. The
incorporation of CO, CO
life safety sensors for monitoring by the W8735D is not
recommended, nor should the W8735D be used in lieu
of fire alarm, smoke detector, gas detector or other life
safety monitoring systems.
, smoke, fire, radon or other
2
69-2027-01
Table of Contents
loading

Summary of Contents for Honeywell W8735D

  • Page 1 Battery back-up enables the TH9421C1004 VisionPRO IAQ Total Home Comfort System, W8735D to let the homeowner know the power is out at the and the TH5320C1002 FocusPRO and T8635L1013 monitored location (optional 9V battery not included).
  • Page 2: Specifications

    — Contact closes during an unacknowledged alert condi- A two-colored LED indicator is located in the lower right tion corner of the W8735D Telephone Access Module that indicates device power and battery health. The LED has the following states: • Steady Green: Input powered, battery health is good •...
  • Page 3: Installation

    Location Outdoor Low Temp Limit (high priority, default 40° F Locate the W8735D near the HVAC equipment and where (4° C) The outdoor temperature dropped below the low limit access to the telephone line is available. See Fig 1.
  • Page 4: W8735D Base Installation

    See Fig. 3. IMPORTANT Turn OFF all power to heating and cooling equip- ment. 1. Position the W8735D on the wall outside of the indoor HVAC equipment. Level the module for appearances only; the module functions properly even when not MOUNTING level.
  • Page 5 W8735D (Channels and Auxiliary Input and Output). 6. As needed, adjust the position of the grommet and 2. Remove the cover from the W8735D by gently pulling press it into place in the fitting provided on the base. the cover plate outward to disengage the friction See Fig.
  • Page 6 Connect terminals 1/D, 2/R, 3/B from the desired channel See Fig. 6 – Fig. 9 for typical W8735D wiring applications. (starting with the channel 1 bus) of the W8735D to the other network devices using a 3.5 mm slotted screw driver. Fig. 5 describes the terminal connections for each channel.
  • Page 7 POWER-CLOSED/ SPRING-OPEN ARD DAMPER VISIONPRO IAQ/FocusPRO EnviraCOM™ THERMOSTATS TELEPHONE POWER M23865 IF ALL FOUR EnviraCOM™ TERMINAL BLOCKS ARE OCCUPIED, YOU MAY SIMPLY CONNECT TO 1, 2 AND 3 ANYWHERE ON THE BUS. Fig. 7. W8735D with EnviraZone Panel (W8835). 69-2027—01...
  • Page 8 THE FOCUSPRO ENVIRACOM THERMOSTAT CAN NOT BE USED IN CONJUNCTION WITH THE R7184 AND W8735D. M23866A TELEPHONE POWER M23867 Fig. 8. W8735D with Oil Primary (R7184 P and U). Fig. 9. W8735D with VisionPRO IAQ and Equipment Interface Module (TH9421C1004/THM5421C1008). 69-2027—01...
  • Page 9 AUXILIARY OUTPUT (AUX-OUT) Auxiliary Input and Output Applications The Auxiliary Output closes in the event an alert condition is detected from the W8735D or from the Auxiliary input. The output remains closed until the user acknowledges the alert AUXILIARY INPUT (AUX-IN) TERMINAL: condition even though the condition itself may have been •...
  • Page 10 W8735D TELEPHONE ACCESS MODULE CHANNEL 1 CHANNEL 1 CHANNEL 2 CHANNEL 2 AUXILIARY SENSOR (DRY CONTACTS) N.C. N.C. OUTPUT OUTPUT AUXILIARY AUXILIARY INPUT INPUT COMBINATION OF DEVICES CONNECTED IN SERIES TO ANNUNCIATE POWER FROM THE AUXILIARY INPUT MAY BE DRAWN FROM AN ACTIVE ON ANY EVENT ON THE AUX-IN LOOP.
  • Page 11: Replacing The Top Cover

    Fig. 17. Wiring the AUX-OUT Terminal Block to Line 24 Vac/dc Sensor. Voltage Annunciating Device (Buzzer). Replacing the Top Cover Reinstall the cover on the W8735D as described below: 1. Align the four latches on the cover with the receptacles on the base. CHANNEL 1 NOTE: Cover goes on only one way.
  • Page 12: Battery Installation

    2. While connected to the W8735D, pick up a house tele- BATTERY INSTALLED phone receiver and try to acquire a dial tone by pressing the flash key. If you hear the W8735D hang up a few seconds later the W8735D is operating correctly, other- M23760 wise check the phone lines and replace the device.
  • Page 13: Installer Setup

    (1, 2, 3, 4), the W8735D will direct the caller to the date, pass code, alerts, call and ring options, limit settings, pass code menu in order to change the pass code.
  • Page 14 To exit the Main menu, press the # key. Review your settings to confirm that they are correct for your application. NOTE: The W8735D has an eight second time-out if no input is received. After eight seconds, the W8735D asks “Are you still there?”, and repeats the last prompt.
  • Page 15: Thermostat Menu

    The Time and Date menu allows you to set the current time The W8735D limits remote access to the HVAC equipment by and date for the system (for the W8735D and all connected implementing a pass code. The pass code must be reset from thermostats).
  • Page 16: Alert Menu

    EnviraCOM alarms, and control alarms via the telephone. Use From the Alert menu, press 2 on the telephone keypad the W8735D Alert menu to set the alert priority level in order and follow the voice prompts to set the low priority dial- to set dial-out times for low priority alerts, and to retrieve the out time for each alert.
  • Page 17: Call And Ring Menu

    IMPORTANT Discuss with the homeowner if you, the HVAC con- The W8735D stores the last ten (10) alerts in its memory. Use tractor, are providing a monitoring service. When you the Retrieve Alert History sub-menu to review the last ten have agreed, enter the contractor telephone number alerts detected in the system.
  • Page 18: Limit Menu

    If these limits are reached due to an abnormal NOTE: If this number is not programmed, a dial-out condition, the W8735D will dial-out the alert. See Table 9 for a sequence for the primary contact telephone number list of the limit settings and corresponding defaults.
  • Page 19 Temperature Limit setting and your dial-out alert is active, the Temperature Limit setting and your dial-out alert is active, the W8735D dials out and the AUX-OUT contact closes. For more W8735D dials out and the AUX-OUT contact closes. For more information on dial-out alerts—...
  • Page 20 If the outdoor temperature is higher than your high limit setting If the outdoor temperature is lower than your Low Limit setting and your dial-out alert is active, the W8735D dials out and the and your dial-out alert is active, the W8735D dials out and the AUX-OUT contact closes.
  • Page 21 If the thermostat displays an indoor humidity lower than your If the thermostat displays an indoor humidity higher than your low limit setting and your dial-out alert is active, the W8735D high limit setting and your dial-out alert is active, the W8735D dials out and the AUX-OUT contact closes.
  • Page 22 • Press 1 to announce each zone by its name or press 2 To return to the Main menu, press the * key at any time. to announce each zone by number only. Table 11. W8735D Voice Menu Tree — Zone Settings • Follow the voice prompts. Menu.
  • Page 23: System Checkout

    2 to enter the Global Thermostat Settings has been out for one hour.” sub-menu. 3. If the call is answered by a voice mail box, the W8735D 5. Use the W8735D Telephone Access Module’s thermo- leaves the power failure message on the voice mail box...
  • Page 24: Sending Messages

    Telephone Access Module. The contractor may use a special code (last five digits of the entered contractor telephone number) to access the W8735D Alert History only. Without the full access code, the contractor cannot access any other features.
  • Page 25: Troubleshooting

    The EnviraCOM bus may be Check wiring to the 1/D, 2/R, 3/B terminals on the outdoor temperature, or thermostat disconnected. W8735D or the 1, 2, 3 terminals on thermostats or information is given. panels. Remove the top cover and check the communication LED on the appropriate circuit board.
  • Page 26 W8735D TELEPHONE ACCESS MODULE Table 15. EnviraCOM Alarms Alarm Number Alarm Meaning Igniter Failure Electronics Down Ignition Failure Flame was lost and could not be relit The maximum number of flame loss incidents has been exceeded A manual reset is required...
  • Page 27 W8735D TELEPHONE ACCESS MODULE 69-2027—01...
  • Page 28 W8735D TELEPHONE ACCESS MODULE EnviraCOM™ is a trademark of Honeywell. Aquastat® is a registered trademark of Honeywell. Automation and Control Solutions Honeywell International Inc. Honeywell Limited-Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley, MN 55422 Toronto, Ontario M1V 4Z9 customer.honeywell.com...

Table of Contents