Siemens SPCK420 User Manual

Siemens SPCK420 User Manual

Lcd-keypad
Hide thumbs Also See for SPCK420:
SPCK420/421/422 LCD-Keypad - User Manual
SPCK420/421/422 LCD-Keypad - User Manual
© Siemens Industry - 11-24-2009
© Siemens Industry - 11-24-2009
Table of Contents
loading

Summary of Contents for Siemens SPCK420

  • Page 1 SPCK420/421/422 LCD-Keypad - User Manual SPCK420/421/422 LCD-Keypad - User Manual © Siemens Industry - 11-24-2009 © Siemens Industry - 11-24-2009...
  • Page 2 SPCK420/421/422 LCD-Keypad - User Manual Security Security Further information Target group General safety instructions Meaning of written warning notices Meaning of hazard symbols © Siemens Industry - 11-24-2009...
  • Page 3: Target Group

    SPCK420/421/422 LCD-Keypad - User Manual Security > Target group Target group The instructions in this documentation are directed at the following target group: End user Instruction by technical specialists is necessary. Performs only the procedures for proper operation of the product.
  • Page 4: General Safety Instructions

    SPCK420/421/422 LCD-Keypad - User Manual Security > General safety instructions General safety instructions Further information General information Operation Service and maintenance © Siemens Industry - 11-24-2009...
  • Page 5: General Information

    SPCK420/421/422 LCD-Keypad - User Manual Security > General safety instructions > General information General information Read the general safety precautions before operating the unit. Keep this document for later reference. Always pass this document on together with the product. Please also take into account any additional country-specific, local safety standards or regulations concerning project planning, operation and disposal of the product.
  • Page 6: Operation

    SPCK420/421/422 LCD-Keypad - User Manual Security > General safety instructions > Operation Operation Dangerous situation due to false alarm Make sure to notify all relevant parties and authorities providing assistance before testing the system. To avoid panic, always inform all those present before testing any alarm devices.
  • Page 7: Service And Maintenance

    SPCK420/421/422 LCD-Keypad - User Manual Security > General safety instructions > Service and maintenance Service and maintenance Danger of electrical shock during maintenance Maintenance work must only be carried out by trained specialists. Danger of electrical shock while cleaning the device Do not use liquid cleaners or sprays that contain alcohol, spirit or ammonia.
  • Page 8: Meaning Of Written Warning Notices

    SPCK420/421/422 LCD-Keypad - User Manual Security > Meaning of written warning notices Meaning of written warning notices DANGER Danger of death or severe bodily harm. WARNING Possible danger of death or severe bodily harm. CAUTION Danger of minor bodily injury or property damage...
  • Page 9: Meaning Of Hazard Symbols

    SPCK420/421/422 LCD-Keypad - User Manual Security > Meaning of hazard symbols Meaning of hazard symbols WARNING Warning of hazard area WARNING Warning of dangerous electrical voltage © Siemens Industry - 11-24-2009...
  • Page 10: Directives And Standards

    SPCK420/421/422 LCD-Keypad - User Manual Directives and standards Directives and standards Further information EU directives © Siemens Industry - 11-24-2009...
  • Page 11 SPCK420/421/422 LCD-Keypad - User Manual Directives and standards > EU directives EU directives This product complies with the requirements of the European Directives 2004/108/EC “Directive of Electromagnetic Compatibility” and 2006/95/EC “Low Voltage Directive”. The EU declaration of conformity is available to the...
  • Page 12 SPCK420/421/422 LCD-Keypad - User Manual Introduction Introduction The keypad is a wall-mounted interface that allows: Engineers to program the system through the Engineer Programming menus (password protected) and to set/unset the system; a user can control the system on a day-to-day basis.
  • Page 13 LCD keypad LCD keypad LCD display The keypad display (2 lines x 16 characters) shows all alert and warning messages and provides a visual interface for programming the system (engineer programming only). The display can be adjusted fro contrast and under which conditions the backlight comes on.
  • Page 14 Flashes quickly: (once every 0.25 seconds approx) indicates the keypad is the last expander on the X-BUS If the keypad is being installed for the first time and power is supplied to it before a connection to the controller X-BUS interface is made, the LED remains in the ON state © Siemens Industry - 11-24-2009...
  • Page 15: Overview Of Keypad Types

    SPCK420/421/422 LCD-Keypad - User Manual Overview of keypad types Overview of keypad types Keypad type Model no. Basic Functionality Proximity Detection Wireless Sensor Support Voice Standard Keypad SPCK420 Keypad with PACE SPCK421 Keypad with 868 MHz wireless module SPCK422 Comfort Keypad...
  • Page 16 Keypad Label SPCK420/421/422 Keypad Label SPCK420/421/422 Label on inside of Keypad Pull-down label for providing installer details. Fill in all relevant details when installation is complete. © Siemens Industry - 11-24-2009...
  • Page 17: Using The Keypad Interface

    SPCK420/421/422 LCD-Keypad - User Manual Using the keypad interface Using the keypad interface Keypad display Keypad display RIGHT SOFT KEY This key is used to select the option presented on the right side of the bottom line display. Possible values are:...
  • Page 18 In the IDLE state, displays the current date and time. In Programming mode, this line displays one of the following: The programming feature to be selected The current setting of the selected feature During an alert condition, this line displays the nature of the current alert. © Siemens Industry - 11-24-2009...
  • Page 19: User Programming Via The Keypad

    SPCK420/421/422 LCD-Keypad - User Manual User programming via the keypad User programming via the keypad This section provides User programming options using the LCD keypad. For each menu option, the keypad must be in User programming: Enter a valid User code (default 2222).
  • Page 20 SPC_mnu_overview_user_menu A user’s ability to see menus and options available on the intrusion control panel is programmed by the installation...
  • Page 21 If users cannot see an option described in this manual, they do not have rights to access that functionality. Further information Setting and unsetting the system User menus © Siemens Industry - 11-24-2009...
  • Page 22: Setting And Unsetting The System

    SPCK420/421/422 LCD-Keypad - User Manual User programming via the keypad > Setting and unsetting the system Setting and unsetting the system For each menu option, the keypad must be in User programming: Enter a valid User code (default 2222). To select a programming option, use the up/down arrow keys or enter the digit listed in the table below.
  • Page 23 SPCK420/421/422 LCD-Keypad - User Manual User programming via the keypad > Setting and unsetting the system > UNSET UNSET To UNSET the system: Enter a valid user code. The keypad displays a prompt to unset the system. Press SELECT. The keypad display indicates that the system is unset on the bottom line of the display for approximately 5 seconds.
  • Page 24 SPCK420/421/422 LCD-Keypad - User Manual User programming via the keypad > Setting and unsetting the system > FULLSET FULLSET The FULLSET option provides the following functionality: Full protection to a building (opening of alarm zones activates alarm) Opening of entry/exit zones starts the entry timer. If the alarm is not unset before the entry timer expires, the alarm is...
  • Page 25 SPCK420/421/422 LCD-Keypad - User Manual User programming via the keypad > Setting and unsetting the system > PARTSET PARTSET The PARTSET option provides the following functionality: Perimeter protection to a building while allowing free movement through the exit and access areas Exclusion of EXCLUDE A/B zones from protection Instant activation of alarm on selection of mode;...
  • Page 26: Force To Set

    SPCK420/421/422 LCD-Keypad - User Manual User programming via the keypad > Setting and unsetting the system > FORCE TO SET FORCE TO SET The system can be forced to set while an alarm zone is still open. This operation inhibits the open zone and sets the system as normal.
  • Page 27 SPCK420/421/422 LCD-Keypad - User Manual User programming via the keypad > Setting and unsetting the system > RESTORE RESTORE Alert conditions on the SPC system are indicated on the keypad by a flashing yellow alert LED and by activation of the buzzer.
  • Page 28: Coded Restore

    SPCK420/421/422 LCD-Keypad - User Manual User programming via the keypad > Setting and unsetting the system > CODED RESTORE CODED RESTORE The feature provides the user with the ability to restore alert conditions that would normally only be available to the installation engineer.
  • Page 29: User Menus

    SPCK420/421/422 LCD-Keypad - User Manual User programming via the keypad > User menus User menus For each menu option, the keypad must be in User programming and within the menu option MENUS: Enter a valid User code (default 2222). Scroll to MENUS and press SELECT.
  • Page 30 Further information INHIBIT ISOLATE TEST SET DATE/TIME EVENT LOG CHIME USERS DOOR CONTROL GRANT ACCESS © Siemens Industry - 11-24-2009...
  • Page 31 SPCK420/421/422 LCD-Keypad - User Manual User programming via the keypad > User menus > INHIBIT INHIBIT Zone and alerts from X-BUS devices can be manually inhibited from the keypad. Inhibiting a zone removes that zone from the system for one alarm set period only.
  • Page 32 SPCK420/421/422 LCD-Keypad - User Manual User programming via the keypad > User menus > ISOLATE ISOLATE Zones, system alerts or alerts from X-BUS devices can be manually isolated from the keypad. Isolating a zone removes that zone from the system until the user de-isolates it.
  • Page 33 SPCK420/421/422 LCD-Keypad - User Manual User programming via the keypad > User menus > TEST TEST Scroll to TEST and press SELECT. Scroll to the desired programming option. Further information BELL TEST WALK TEST AUDIBLE OPTIONS © Siemens Industry - 11-24-2009...
  • Page 34: Bell Test

    SPCK420/421/422 LCD-Keypad - User Manual User programming via the keypad > User menus > TEST > BELL TEST BELL TEST To perform a bell test: Scroll to TEST > BELL TEST. Press SELECT. When BELL TEST is selected, the following options available: EXTERNAL BELLS, STROBE, INTERNAL BELLS and BUZZER.
  • Page 35: Walk Test

    SPCK420/421/422 LCD-Keypad - User Manual User programming via the keypad > User menus > TEST > WALK TEST WALK TEST A walk test ensures that the sensors are operating correctly on the SPC system. To perform a walk test: Scroll to TEST > WALK TEST.
  • Page 36: Audible Options

    SPCK420/421/422 LCD-Keypad - User Manual User programming via the keypad > User menus > TEST > AUDIBLE OPTIONS AUDIBLE OPTIONS The audible options are applied as indicators within a walk test. To set the audible options: Scroll to AUDIBLE OPTIONS.
  • Page 37: Set Date/Time

    SPCK420/421/422 LCD-Keypad - User Manual User programming via the keypad > User menus > SET DATE/TIME SET DATE/TIME The date and time can be manually entered on the system. The time and date information is displayed on the keypad and browser and is used on time-related programming features.
  • Page 38: Event Log

    SPCK420/421/422 LCD-Keypad - User Manual User programming via the keypad > User menus > EVENT LOG EVENT LOG Recent events on the system are displayed in the EVENT LOG option. Events flash in one second intervals. Scroll to EVENT LOG and press SELECT.
  • Page 39 SPCK420/421/422 LCD-Keypad - User Manual User programming via the keypad > User menus > CHIME CHIME The chime function can be enabled or disabled on all zones where the chime has been programmed as an audible alert feature. To enable or disable the chime function: Scroll to CHIME and press SELECT.
  • Page 40 SPCK420/421/422 LCD-Keypad - User Manual User programming via the keypad > User menus > USERS USERS Only Manager type users have the ability to add, edit, or delete users, unless a user profile has this capability assigned to their profile. Managers may add, edit or delete users with these steps:...
  • Page 41 SPCK420/421/422 LCD-Keypad - User Manual User programming via the keypad > User menus > USERS > ADD To add users to the system: The creator must be user type MANAGER. Scroll to USERS > ADD. The system generates and displays next available user name.
  • Page 42: Change Code

    SPCK420/421/422 LCD-Keypad - User Manual User programming via the keypad > User menus > USERS > CHANGE CODE CHANGE CODE To change a code: Scroll to CHANGE CODE and press SELECT. A randomly generated code appears. Select new code, if acceptable. Or overwrite by entering a new code and press ENTER.
  • Page 43: Sms Control

    SPCK420/421/422 LCD-Keypad - User Manual User programming via the keypad > User menus > SMS The SPC system support SMS communication from the panel to selected users’ mobile phones as well as users being able to control the SPC system remotely via SMS. These two features work hand in hand as it allows the user to take action using the SMS control after a SMS notification without the need to be physically at the premises.
  • Page 44: Door Control

    SPCK420/421/422 LCD-Keypad - User Manual User programming via the keypad > User menus > DOOR CONTROL DOOR CONTROL This option allows the engineer to control all the doors of the system. Scroll to DOOR CONTROL and press SELECT. Select the door which should be controlled and press SELECT.
  • Page 45: Grant Access

    SPCK420/421/422 LCD-Keypad - User Manual User programming via the keypad > User menus > GRANT ACCESS GRANT ACCESS When engineer or manufacturer access has been allowed, the keypad displays the text ENGINEER ENABLE or MANUFACT ENABLE. Once access has been granted, the user cannot access the system until the engineer has logged off.
  • Page 46 SPCK420/421/422 LCD-Keypad - User Manual Appendix Appendix Further information User rights Zone chart User codes © Siemens Industry - 11-24-2009...
  • Page 47: User Rights

    SPCK420/421/422 LCD-Keypad - User Manual Appendix > User rights User rights Based on the operational features of the SPC system, described below, users have rights attributed to the user profiles. The installation engineer will inform users of their user rights assigned to each user profile. Depending on how the system has been programmed, users may have rights to all or some of these features.
  • Page 48 Manager The UNSET operation unsets the alarm. This menu option is only presented on the keypad after an alarm has been activated and a valid user code has been entered. Restore Standard Manager The RESTORE operation restores an alert condition on the system and clears the alert message associated with that alert condition.
  • Page 49 Access Control User can lock/unlock doors. Web Access Standard* Manager User can access panel through web browser. * Functions not enabled by default for this user but can be selected. User Profile User type Description Default © Siemens Industry - 11-24-2009...
  • Page 50: Zone Chart

    SPCK420/421/422 LCD-Keypad - User Manual Appendix > Zone chart Zone chart...
  • Page 51 Zone # Description © Siemens Industry - 11-24-2009...
  • Page 52: User Codes

    SPCK420/421/422 LCD-Keypad - User Manual Appendix > User codes User codes The system supports 4, 5, 6, 7 or 8 PIN digits for each user, the translation of how many logical combinations / variations can be found in the table below.

This manual is also suitable for:

Spck421Spck422

Table of Contents