Shape The Indoor Side Tubing; Wiring Instructions - Sanyo SAP-KMRV74EH Installation Instructions Manual

Inverter split system air conditioner
Hide thumbs Also See for SAP-KMRV74EH:
Table of Contents
07-370 CMRV3146EH_IU ENG

3-5. Shape the Indoor Side Tubing

(1) Arrangement of tubing by directions
a) Right or left tubing
Cut out the corner of the right/left frame with a
hacksaw or the like. (Figs. 20 and 21)
b) Right-rear or left-rear tubing
In this case, the corner of the frame need not
be cut.
(2) To mount the indoor unit on the rear panel:
Hang the 2 mounting slots of the unit on the
upper tabs of the rear panel. (Fig. 22)

3-6. Wiring Instructions

General precautions on wiring
(1) Before wiring, confirm the rated voltage of the unit
as shown on its nameplate, then carry out the
wiring closely following the wiring diagram.
(2) Provide a power outlet to be used exclusively for
each unit, with a power supply disconnect and cir-
cuit breaker for overcurrent protection provided in
the exclusive line.
(3) To prevent possible hazard due to insulation fail-
ure, the unit must be grounded.
(4) Each wiring connection must be done tightly and
in accordance with the wiring system diagram.
Wrong wiring may cause the unit to misoperate or
become damaged.
(5) Do not allow wiring to touch the refrigerant tubing,
compressor, or any moving parts of the fan.
(6) Unauthorized changes in the internal wiring can
be very dangerous. The manufacturer will accept
no responsibility for any damage or misoperation
that occurs as a result of such unauthorized
changes.
2/6/08
1:31 PM
Page 13
Frame
Left tubing
outlet
13
Fig. 20
Frame
Right tubing
outlet
Fig. 21
Fig. 22