Mitsubishi Electric PURY-RP200 Service Handbook page 86

Hide thumbs Also See for PURY-RP200:
Table of Contents
[ IV Remote Controller ]
[Operation Procedures]
1. Press the [ON/OFF] button on the remote controller to bring the unit to a stop. The display will appear as shown in the previous page (Normal
display).
2. Press buttons
[CHECK] and [
1
under the remote controller function selection mode. Press button
under the remote controller function selection mode.
Skip-Auto-Mode setting (Making the automatic operation mode unselectable)
This setting is valid only when the controller is connected to the simultaneous cooling/heating type air conditioning units that
support the automatic operation mode.
"
" blinks and either "ON" or "OFF" lights up on the controller. Pressing the
between "ON" and "OFF."
When set to "ON," the automatic operation mode is available for selection in the function selection mode.
When set to "OFF," the automatic operation mode is not available for selection in the function selection mode, and an automatic operation
cannot be performed.
(The automatic operation mode is skipped in the function selection mode sequence.)
Operation mode display selection mode (Changing the type of display that appears during the automatic mode operation)
will blink, and either
switch between "ON" and "OFF."
When it is set to ON,
When it is set to OFF, only
Restricted preset temperature range mode (The range of preset temperature can be changed.)
1) Temperature range setting for the cooling/dry mode
will light up in the display window, and the temperature range for the cooling/dry mode will appear on the display.
[Lower limit temperature]: Appears in the preset temperature display window [Upper limit temperature: Appears in the time display window
Switch between the Lower and Upper limit temperature setting by pressing the
[The left figure shows the display that appears when the current temperature range setting is between 19 C and 30 C in the Cool/Dry mode,
and the lower limit temperature is selected to be set.]
Press button
[TIMER SET ( ) or ( )] to set the lower limit temperature to the desired temperature.
4
[Settable range for the lower limit temperature] : 19 C
[Settable range for the upper limit temperature] : 30 C
2) Temperature range setting for heating
"
" and the settable temperature range for heating appear on the display.
As with the Cool/Dry mode, use the
[Settable range for the lower limit temperature] : 17 C
[Settable range for the upper limit temperature] : 28 C
3) Temperature range setting for the automatic mode
"
" and the temperature range for the automatic operation mode appear on the display.
As with the Cool/Dry mode, use the
[Settable range for the lower limit temperature] : 19 C
[Settable range for the upper limit temperature] : 28 C
Room temperature display selection mode (Switching between the display or non-display of room temperature on the controller)
" 88 C " blinks and either "ON" or "OFF" lights up on the controller. Pressing the
switches between "ON" and "OFF."
When set to "ON," room temperature always appears on the display during operation.
When set to "OFF," room temperature does not appear on the display during operation.
HWE10020
] simultaneously for 2 seconds to go into the "Skip-Auto-Mode setting."
[SET TEMP. (
2
[TIMER SET (
) ((
ON
or
OFF
will light up.
"
"
"
"
[TIMER SET (
) ((
will appear on the display during automatic operation mode.
will appear on the display during automatic operation mode.
[TIMER SET (
) ((
30 C (Settable up to the upper limit temperature that is shown on the display)
19 C (Settable up to the lower limit temperature that is shown on the display)
5
[CLOCK-ON-OFF] button and the
28 C (Settable up to the upper limit temperature that is shown on the display)
17 C (Settable up to the lower limit temperature that is shown on the display)
5
[CLOCK-ON-OFF] button and the
28 C (Settable up to the upper limit temperature that is shown on the display)
19 C (Settable up to the lower limit temperature that is shown on the display)
˚ C
[TIMER SET (
) ((
- 77 -
)] or
[SET TEMP. (
3
[TIMER SET (
4
))] button
Press button
4
[TIMER SET (
))] button
[CLOCK-ON-OFF] button. The selected temperature setting blinks.
5
))] button
4
[TIMER SET ( ) or ( )] to set the temperature range.
[TIMER SET ( ) or ( )] to set the temperature range.
4
[TIMER SET (
4
))] button
)] to go into the other four modes
) or (
)] button switches
) or (
)] in this state to
) or (
)] button
˚ C