  • Page 1: Installation Guide

                                                      NM-IP100 Installation Guide...
  • Page 2 INFORMATION TO USER  CAUTION  RISK OF ELECTRIC SHOCK,      DO NOT OPEN    CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,  DO NOT REMOVE COVER (OR BACK).  NO USER SERVICEABLE PARTS INSIDE.  REFER SERVICING TO QUALIFIED SEERIVCE PERSONEL.      This  symbol  is  intended  to  alert  the  user  to  the  presence  of  un‐insulated  “dangerous voltage” within the product’s enclosure that may be of sufficient  magnitude to constitute a risk of electric shock to persons.    This  symbol  is  intended  to  alert  the  user  to  the  presence  of  important  operating ...
  • Page 3: Table Of Contents

      NM‐IP100  Table of Contents 1. FEATURES ....................... 4 2. PACKAGE CONTENTS ....................5 3. PART NAMES ......................6 4. INSTALLATION ......................7 4.1. Installation Template ......................8 4.2. Manual adjustment for 3‐axis movements ................ 8 4.3. Lens Focus Adjustment ...................... 9 4.4. Setting the Image Attribute....................9 5. CONNECTIONS ...................... 10 6. CONFIGURATION ....................11 6.1.Set up network environment .................... 11 6.2.View video on web page ....................11 6.2.1.View video using IPAdmin Tool..................
  • Page 4: Features

      NM‐IP100  1. FEATURES Camera  • Indoor Fixed Mini Dome IP Camera   • High Quality Compression in real time streaming   • 1/4” VGA CMOS  Streaming  • Dual streaming mode (such as different codec/resolution/bit rate and so on.)  • De‐interlacing on DSP  • Burnt‐in text supported  • Unicast/Multicast supported  Video/Audio  • Video compression: H.264/MPEG4/MJPEG (30FPS@D1)  • Audio compression: G.711(µLaw, aLaw)/PCM  • Video Motion Detection supported  • 2‐way mono audio supported  Network  • RTSP/ HTTP protocol supported  • 10/100 Base‐T Ethernet  Additional Features  • Built‐in Video Content Analysis  • OSD supported  • SDK (Software Development Kit) provided ...
  • Page 5: Package Contents

      NM‐IP100  2. PACKAGE CONTENTS Unpack carefully and handle the equipment with care. The packaging contains:    Camera  DC power adaptor      Extension cable    (for LAN, power connector, and audio )  Quick Installation Guide      Installation Template  Screws and Anchor block      Hex wrench driver                The above contents are subject to change without prior notice.  Note         5 ...
  • Page 6: Part Names

      NM‐IP100  3. PART NAMES ①  ②  ③  * Models herein and their appearance  are subject to change without any prior  notice.    ①LAN Connector (Ethernet)  This is a RJ45 LAN connector for 10/100 Base‐T Ethernet.       ② Audio in/ out Cable  Thecamera has a mono audio input and a mono audio output.      ③Power Adaptor Connector (DC 12V)  The  camera requires a DC 12V 1A adapter for power supply.      6 ...
  • Page 7: Installation

      NM‐IP100  4. INSTALLATION  Connect the LAN cable, power supply  cable,  and  the  video  loop  out  cable  with the camera.       Place the installation template on the  2)  ceiling.      Drill  two  holes  on  the  template  and  3)  insert  anchor  blocks  into  the  holes.  Fasten the camera with screws.     Put  the  dome  cover  on  the  main  4) ...
  • Page 8: Installation Template

      NM‐IP100  4.1. Installation Template 2‐Ø6 Ø125 Ø30   4.2. Manual adjustment for 3-axis movements   After  installation,  make  a  manual  adjustment  on  the  inner  liner.  Perform  3‐axis  movements  manually  by  turning  the  inner  liner  to  different  directions  as  above,  and  check  if  it  moves  properly. After adjustment, fasten the screw of the rotation axis. ...
  • Page 9: Lens Focus Adjustment

      NM‐IP100  4.3. Lens Focus Adjustment   1) Open the dome cover from the device.  A  2) Uncover the latch(C) carefully to  remove the lens cover.    3) Rotate the lens focus ring(D) to adjust  the focus and fasten the screw(E)  using the included hex wrench.    4) Push the lens cover to the module  C  until the latch(C) clicks into position.  D    5) Attach the dome cover by aligning  protrusion on the body (B) with the  inverted triangle mark of the dome  cover (A). Turn the dome cover  E  clockwise to lock.  * Models herein and their appearance are subject to change without any prior notice.    4.4. Setting the Image Attribute You can set the image attribute of camera through the webpage.  The menu of image attribute can be seen under Setup > Video & Audio > Video‐in > Attribute ...
  • Page 10: Connections

      NM‐IP100  5. CONNECTIONS LAN  DC 12V      Make sure the polarity is correct. Incorrect connection may cause malfunction  or damage to the IP device.  Caution     Power Adaptor Connector (DC 12V)    Caution         10 ...
  • Page 11: Configuration

      NM‐IP100  6. CONFIGURATION 6.1.Set up network environment The default IP address of your IP device is 192.168.XXX.XXX. You can find the available IP address  from the MAC address of your device. Please make sure the device and your PC are on the same  network segment before running the installation. If the network segment between your PC and  the device is different, change your PC’s settings as below.    IP address     :  192.168.xxx.xxx  Subnet mask:  255.255.0.0      6.2.View video on web page View  the  live  video  on  a  web  page  using  your  IP  device  and  its  IP  address.  You  can  use  the  IPAdminTool or enter the IP address on the web page.  ...
  • Page 12   NM‐IP100  To use the IPAdminTool and view the live video on a web page:    1. Start IPAdminTool. Names and info of currently activated devices appear as a list.  2. Right‐click on the desired device and select Web view.   3. Select Continue to this website on the Security Certificate Alert page.  (The explanation and captured images at this manual are mainly on the basis of Internet  Explorer 7.0)      4. Click  pop‐up  blocked and  install the ActiveX  control by  clicking  the Install  button. You  need to install the ActiveX for displaying the images.            12 ...
  • Page 13   NM‐IP100  5. Wait for a few seconds while the web page loads. Then the live video is displayed on the  main page of the web browser.    6. If  the  live  video  is  not  displayed  and  “Can  not  Create  XMLDOMDocument  Install  MSXML4.0”  message  is  shown  as  below,  please  download  and  Install  from  the  link  below.  http://www.microsoft.com/downloads/details.aspx?familyid=3144B72B‐B4F2‐46DA‐ B4B6‐C5D7485F2B42&displaylang=en  (VCA Library requires MS XML 4.0 library which is an xml parser made by Microsoft.)        13 ...
  • Page 14: View Video Using Ip Address

      NM‐IP100  6.2.2.View video using IP address View the live video on a web page using your IP device and its IP address. To have the correct  IP address ready and use it on a web page:    1. Convert a MAC address to an IP address or check the IP address on the IPAdminTool.  (The MAC address is attached on the side or bottom of the device.)    MAC address = 00‐13‐23‐01‐14‐B1 → IP address = 192.168.20.177  the Hexadecimal number to Decimal number.      2. Open a web browser and enter the IP address of the device.  3. Click Continue to this website on the Security Certificate Alert page.  4. Click  pop‐up  blocked  and  install  the  ActiveX  control.  You  need  to  install  the  ActiveX  for  displaying the images.  5. Wait for a few seconds while the web page loads. The live video is displayed.  6.3.
  • Page 15: Appendix (A): Specifications

      NM‐IP100  APPENDIX (A): SPECIFICATIONS Summary Camera Module  Image Sensor  1/4” VGA CMOS  Effective Pixels  640 x 480  Scanning system  Progressive Scan  CMOS  Horizontal    550 TV Lines  Resolution  Min.  3   Lux Color  Illumination   0.1 Lux DSS On  Focal Length 3.6 mm, F.# 2.0, Board type,  Lens  Lens for Security Camera  Shutter Speed  1/60 ~ 1/100,000  Day & Night  Not Supported  Video  Compression Format  H.264, MPEG‐4, MJPEG Selectable per Stream  Number of Streams  Dual Stream, Configurable  Resolution  , 4CIF , VGA, CIF, QCIF  Compression FPS  30 fps   Deinterlacing  Supported (DSP) ...
  • Page 16: Electrical Characteristics

      NM‐IP100  Electrical Characteristics Video Output  1Vp‐p, 75Ω  Audio Input  Linein, 1.43Vp‐p(Min 1.35Vp‐p, max 1.49 Vp‐p), 39 KΩ  Audio Output  Lineout, 46mW Power, 16 Ω  Power Source(Approx)  12 V DC 290 mA   Environment Condition Operating Temperature  0 ˚C ~ 50 ˚C (32˚F ~ 122 ˚F)  Operating Humidity  Up to 85% RH  VCA (Video Content Analysis) VCA Presence (Included as Standard)  High Performance  Advanced Tracking Algorithm, Low False Alarm Rate  Easy to Use  Intuitive Web Browser Interface  Detection Zones  Multi‐segment Polygons and Lines  On‐screen Display  Real‐time Display of Tracking Data and Events  Stream or Analog video out  Burnt‐in Annotation  (※Analog  video  out  support  can  vary  depending  on  the  device  model and hardware version and the firmware version) ...
  • Page 17: Appendix (B): Dimensions

      NM‐IP100  APPENDIX (B): DIMENSIONS Ø124  R50    (Unit: mm)      17 ...
  • Page 18: Revision History

      NM‐IP100  REVISION HISTORY MAN#  DATE(M/D/Y)  Comments  01A.00  07/23/2009  Created.  02A.00  07/04/2009  FW 1.00.07 official release version  02A.01  08/06/2009  Added images to  package contents   02A.02  08/24/2009  Added the requirement of VCA : MSXML4.0   02A.03  09/03/2009  Added Power Consumption  Added Focus Adjustment  02A.04  09/25/2009  Added Setting the Image Attribute  02A.05  09/29/2009  Changed VCA specification  03A.00  10/13/2009  FW 1.02.02 official release version  03A.01  10/15/2009  Changed the Reset and Factory default description  03A.02  12/09/2009  Corrected Errata about Network Protocol  Changed Image Sensor specification (1/3”‐> 1/4” VGA CMOS)  Added Description about up‐scaled resolutions  03B.00 ...