    If this product fails to operate normally, contact the nearest service center. Never disassemble or modify this product in any way. (SAMSUNG is not liable for problems caused by unauthorized modifi cations or attempted repair.) When cleaning, do not spray water directly onto parts of the product. Doing so may cause fi re or electric shock.
  • Page 4 safety information Keep out of direct sunlight and heat radiation sources. It may cause fi re. Install it in a place with good ventilation. Avoid aiming the camera directly towards extremely bright objects such as sun, as this may damage the CCD image sensor.
  • Page 5: Important Safety Instructions

    important safety instructions Read these instructions. Keep these instructions. Heed all warnings. Follow all instructions. Do not use this apparatus near warter. Clean only with dry cloth. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. Do not install near any heat sources such as radiators, heat registers, or other apparatus (including amplifi...
  • Page 6 CAUTION These servicing instructions are for use by qualifi ed service personnel only. To reduce the risk of electric shock, do not perform any servicing other than that contained in the operating instructions unless you are qualifi ed to do so. PRECAUTIONS ON INSTALLATION AND USE Be sure to install the product vertically.
  • Page 7: Product Specifications

    Camera ID DIP Switch Settings Preparing Adapter and Cables Product Confi gurations Camera Installation SETUP Interface Symbols Using and setting the menus OSD Menu Chart Camera Setup (SCU-2370) Camera Setup (SCU-9051/VAC/VAC1) Sequence Setting P/T Setting OSD Setting Alarm Setting Initialize Status TROUBLESHOOTING Troubleshooting PRODUCT SPECIFICATIONS Product Specifi...
  • Page 8 Features Versatile protocols and coaxial communication Supports RS-422/485 communications and coaxial communication (Pelco-C). RS-422/485 (10 species) : SAMSUNG-T, SAMSUNG-E, Pelco(D/P), Panasonic, Honeywell, AD, Vicon, GE, Bosch. Coaxial Communications: Pelco Coaxitron (automatic detection) Wide Range Auto Security Functions Multiple Preset Function Saving : Up to 12 camera image properities can be saved individually to provide high quality pictures.
  • Page 9: What's Included

    WHAT’S INCLUDED Check if the following items are included in the product package. Main Body Sunsheild/Screw (M5) X 2 L-type hexagon wrenches (4.0mm) Positioning System SCU-2370 SCU-9051 SCU-VAC User Guide SCU-VAC1 Fuse (2EA) User Manual CD Manual Mount The following items are sold separately from the camera.
  • Page 10: Component Names And Functions

    COMPONENT NAMES AND FUNCTIONS Front ➌ ❶ ➋ (SCU-2370/VAC/VAC1) (SCU-9051) ❶ Lens ❷ Wiper : Use it to wipe out the front glass of the housing. ❸ Sunshield  SCU-VAC/VAC1 models support various lens and camera installations upon user’s requirement.
  • Page 11 Back ❶ ➋ ➌ ➍ ❶ COM/ID Setup Switch ❷ Video Out Cable ❸ Communication Cable ❹ Power Cable  For the DIP switch settings, please refer to the on Pages 18~21. English - 11...
  • Page 12: Connection And Installation

    connection & installation Assembling Lens and Camera Lens Camera SLA-880 SHC-745 SLA12240 SCB-3000 SCB-4000 Basic Wiring How to connect (SHC-745) 485- 485+ Power module Communication / Control (485) How to connect (SCB-3000) Light Projector (Motion Detection) How to connect (SCB-4000) Power Module * The power adaptor (AC) has no polarity.
  • Page 13 How to connect (SLA-880) FOCUS_MOTOR LEVEL ZOOM_MOTOR CABLE 7Lines : Adjusting the zoom and focus Auto Iris Jack Lens Label Board Label GREEN (Far) FOCUS_MOTOR+ Focus BLACK (Near) FOCUS_MOTOR- YELLOW (Wide) ZOOM_MOTOR+ Zoom RED (Tele) ZOOM_MOTOR- How to connect (SLA-12240) AD_FOCUS_P FOCUS_MOTOR AD_ZOOM_P...
  • Page 14 Camera Cam I/F Board Camera Cam I/F Board Motion RS-485 Detection (SCU-VAC (SCU-9051) / VAC1) SHC-745, SCB-3000 SCB-4000  Check !! ID=1, Baudrate=9600-N-1 (SCU-9051 : 9600-E-1)  When shipped, all switches are set to OFF by default. connection & installation...
  • Page 15: Camera Wiring Interface Board

    Camera Wiring Interface Board For the camera wiring, please refer to the picture below. (When using coaxial communication, a separate control signal connection is not required.) Video Power Supply Communications/ Control Signal Alarm Input Lighting Power Alarm Output Communication/Control Signal Diagram RS-422 Communications RS-485 Communications RXD+...
  • Page 16: Camera And Appliances Wiring Diagram

    Connecting the power connector and GND incorrectly to the NC/NO and COM ports may cause a short circuit and fi re, damaging the camera. CAMERA AND APPLIANCES WIRING DIAGRAM Connecting with Samsung Techwin’s “Stand Alone DVR” RS-485 : Camera Stand Alone DVR...
  • Page 17 Connecting with the Samsung Techwin Controller SPC-6000 RS-485 : Camera RXD+ TXD+ TXD- RXD- RS-422 : Camera RXD+ TXD+ RXD- TXD- RXD+ TXD+ RXD- TXD- To connect to Samsung PC DVR RS-485 : Camera PC DVR RXD+ RXD- SRP-1610/1650...
  • Page 18: Protocol Settings

    1 ~ 4 Protocol Settings Transfer Method (RS-485/422) Settings Response Mode Settings Terminal Resistance TX Terminal Resistance RX TEST Factory Default Protocol Settings Select a communication protocol for the camera. Protocol SAMSUNG-T SAMSUNG-E Pelco-D Pelco-P Panasonic Vicon Honeywell Bosch connection & installation...
  • Page 19: Termination Settings

    Communication Method Settings Select a communication method for the camera. Function Transfer Mode Switch RS-422(4Wire) RS-485(2Wire) Communication Response Settings Select a communication response method for the camera and controller: Response or No Response. Function Response Mode Switch Response No Response Termination Settings To prevent the attenuation of communication signals between the camera and controller, the items at the end of line must be set up with the termination settings.
  • Page 20: Baud Rate Settings

    connection & installation Baud Rate Settings Select the transfer speed of a selected communication protocol. Baud Rate(BPS) 2,400 4,800 9,600 19,200  To use a third party controller with this product, please contact our After-Sales Service or Technology Department.  Controls Using Different Protocols AD Protocol VICON Protocol...
  • Page 21: Camera Id Dip Switch Settings

    CAMERA ID DIP SWITCH SETTINGS Assign a unique number for each camera to identify itself from others. The initial value of the switch is “0”, and all of the 8 switches are defaulted to OFF. Each switch has a unique value, and the board ID is the sum of the values of the switches.
  • Page 22: Preparing Adapter And Cables

    connection & installation PREPARING ADAPTER AND CABLES Power Adapter Power adapter has the capacity of AC 24V/6A. (UL Listed Class 2 Adapter) Video Cable The camera’s video output port is connected to the monitor with a BNC coaxial cable, shown below : If the distance between the camera and the monitor exceeds the recommended maximum, please use an auxiliary video amp.
  • Page 23: Product Configurations

    PRODUCT CONFIGURATIONS RS-485 SRD Series RS-485 SRD Series Coaxial Communication SRD Series Coaxial Communication SRD Series CONTROLLER (MAIN) CONTROLLER (SUB) CONTROL LINE VIDEO LINE CONTROL/VIDEO LINE English - 23...
  • Page 24: Camera Installation

    connection & installation CAMERA INSTALLATION Pedestal Mount Wall Mount  Do not connect the camera to a power outlet until the installation is complete. Supplying power in the middle of the installation may cause fi re or damage the product. ...
  • Page 25 To install the light projector Fix 4 hex screws to secure the camera on the bracket through the holes prepared, from the bottom side of the bracket. To secure the light projector on the bracket, fi x 4 hex screws through the holes prepared on the boundary of the bracket, from the bottom side.
  • Page 26: Interface Symbols

    setup INTERFACE SYMBOLS Motion Detection Standby/Operation Display : When in standby mode, the “ ” in the upper right of the screen blinks and then changes to “ ” if motion is detected. Alarm Input Port Status Display : " 1 ", " 2 " and " " in the upper right of the screen blink. Current Alarm Port Display According to Input Alarm Ports(Priority) : Only one of "...
  • Page 27: Using And Setting The Menus

    USING AND SETTING THE MENUS OSD (On-screen Display) Indicators Camera Setting Has submenu Focus & Zoom White Balance Has no submenu ------ ------ Operating Your Camera Panning and Tilting : Use the joystick of the controller or its direction buttons. Controlling Zoom : Move the joystick clockwise (Tele) or counterclockwise (Wide), or use the zoom buttons.
  • Page 28: Osd Menu Chart

    setup OSD Menu Chart You can have an overall view of the menu structure. For more information, refer to the applicable page or section in the manual. For more information about SCU-VAC, refer to the “Camera Setting” section in the manual that was provided when you purchased the camera module.
  • Page 29 CAMERA SETUP (SCU-2370) The camera setting section in this manual is explained based on SCU-2370. For SCU-9051, refer to page 40. For SCU-VAC products, refer to the own user manual provided separately. Focus and Zoom Settings Focus Mode Main Menu AUTO : Performs continuous auto-focus.
  • Page 30 setup Zoom Tracking Through this menu you can set up the camera’s focus mode when Main Menu zooming. Camera Setting Mode Sequence Setting AUTO : Auto-focuses when zooming. P/T Setting TRACKING : Focuses manually when zooming. OSD Setting OFF : Disable the focus modes when zooming. (Full manual Alarm Setting mode) Initialize...
  • Page 31: White Balance

    White Balance The White Balance menu adjusts the balance of the screen colors Main Menu under different lighting conditions. Camera Setting ATW : Adjusts the screen color automatically. Sequence Setting P/T Setting INDOOR : Adjusts the screen color to be optimal in an indoor environment.
  • Page 32 setup Exposure The Exposure settings are to control the camera’s exposure meter. Main Menu Brightness : Adjusts the screen brightness. Camera Setting (Over 50: Brighter, Under 50: Darker) Sequence Setting P/T Setting Iris AUTO : Automatically adjusts the exposure meter. OSD Setting MANUAL : Enables manual adjustment of the exposure Alarm Setting...
  • Page 33: Back Light

    Back Light Unlike other cameras, Samsung Techwin’s unique W-V DSP chip Main Menu gives you a clear image of the subject even with bright backlight. Camera Setting Back Light Mode Sequence Setting OFF : Disables the Backlight mode. P/T Setting HLC : Activates the High Light Compensation mode.
  • Page 34 setup HLC Masking Area Level : Adjusts the HLC sensitivity level. Mask Color : Adjusts the mask color on the high lighted area.  Even if HLC is on, car license plates may not be detectable depending on the location and angle of the camera as well as the lighting condition.
  • Page 35 AGC(Auto Gain Control) AGC (Automatic Gain Control) adjusts the camera’s gain control Main Menu and the screen brightness if the camera has captured an object Camera Setting under low-light conditions. Sequence Setting OFF: P/T Setting AGC does not function. OSD Setting LOW/MEDIUM/HIGH: Alarm Setting As the level increases to HIGH, brighter the captured screen in a...
  • Page 36: Ssnr(Samsung Super Noise Reduction)

    SSNR(Samsung Super Noise Reduction) SSNR significantly reduces the amount of low luminance noise. Main Menu OFF : Disables the noise reduction function. Camera Setting LOW : Reduces only a small amount of noise, but generates Sequence Setting almost no afterimage.
  • Page 37 SSDR(Samsung Super Dynamic Range) SSDR illuminates darker spots of an image while retaining the Main Menu same light level for brighter spots to even out the overall brightness Camera Setting of the image with high contrast between bright and dark spots.
  • Page 38: Day & Night

    setup Day & Night The Day & Night function allows the camera to switch between the Main Menu Color and B/W modes. Camera Setting MODE Sequence Setting AUTO : Operates in Color mode most times, and switches P/T Setting to B/W mode if a low light level is detected during OSD Setting nighttime.
  • Page 39 Others Sync : Enables selecting Internal Synchronization or the Main Menu external Line Lock. Camera Setting INTERNAL : Synchronizes the camera’s output timing to the Sequence Setting internal crystal. P/T Setting LINE LOCK : Synchronizes the camera’s output timing to the AC adapter power to synchronize multiple OSD Setting cameras.
  • Page 40 CAMERA SETUP (SCU-9051/VAC/VAC1) This setup guide is intended for SCU-9051/VAC/VAC1 that may differ depending on the camera module. Protocol Type Main Menu This enables you to specify the protocol type of the ► Camera Setting camera module. Improper protocol settings may Sequence Setting result in an abnormal operation of the product.
  • Page 41: Main Setup

    Per communication settings of the camera module - SCU-VAC/VAC1: ID=1, baud rate =9600, communication mode= 8-N-1 - SCU-9051: ID=1, baud rate =9600, communication mode = 8-E-1 This instruction applies to SCU-9051. For VAC/VAC1 camera settings, refer to each product’s user manual. Main Setup...
  • Page 42 setup BRIGHTNESS Press the SET button while the cursor is aligned with “1. BRIGHTNESS” to display the BRIGHTNESS MAIN SETUP sub menu shown below. Press the LEFT button or ► 1. BRIGHTNESS AUTO RIGHT button while the cursor is aligned with “AUTO” 2.
  • Page 43 NUC (Calibration) Press the SET button while the cursor is aligned with MAIN SETUP “4. NUC” to calibrate. Screen operations will then be 1. BRIGHTNESS AUTO temporarily suspended. 2. CONTRAST MANUAL 3. RANGE AUTO ► 4. NUC 5. NUC MODE INTERVAL NUC MODE (Calibration Mode) NUC(Non-uniformity Correction) is a menu calibrating all pixel’s characteristics to get better image.
  • Page 44: Image Adj

    setup IMAGE ADJ Use this menu to adjust images. After you select this MAIN SETUP option, the following sub menu will appear. 1. BRIGHTNESS AUTO 3D-DNR (Noise Reduction) : 2. CONTRAST MANUAL Press the LEFT button or the RIGHT button to 3.
  • Page 45 SPECIAL (Environment Settings Mode) Use this menu to adjust environment settings items related to areas such as screen display, video output, and MAIN SETUP communications. Press the SET button while the cursor is 1. BRIGHTNESS AUTO aligned with “7.SPECIAL” to display the following sub menu. 2.
  • Page 46 setup TEMP ADJ : Use this option to change the temperature unit. Press the button while the cursor is aligned with SPECLAL SETUP “4.TEMP ADJ” to change temperature display 1. TV SYSTEM on/off and temperature unit °C/°F. 2. LANGUAGE ENGLISH 3.
  • Page 47 Sequence Setting Preset This function enables the memorization of a selected location and Main Menu activates the Pan, Tilt, and Zoom functions at that location. Saved locations can be recalled using the Preset Execute command. Camera Setting Sequence Setting Setting Up Preset Numbers : P/T Setting Selecting the Preset Setting menu brings up a screen as shown below.
  • Page 48 setup PTZF Setting (SCU-VAC/VAC1) If you open the PTZF setup menu, you will see the following PTZF Setting window. You can use the joystick to select a desired number. Preset = 001 (1~255) Select a preset number and press ENTER. You will move to the setup screen.
  • Page 49 Preset Edit [001]  MD Function’s Prerequisite when using SCU-VAC/VAC1 (SCB-3000) : 000/000/1X Set Alarm Out of Camera Setting – Open Camera Menu – Special After Action Intelligence menu to ON.  For SCU-VAC/VAC1, the MD function will be activated 1.5 seconds after you have moved to the preset position.
  • Page 50 setup Preset Name Setting Main Menu Using this function, you can add names to preset locations. Camera Setting up to 12 characters. Sequence Setting Once a name is entered, use the joystick and the Enter key to P/T Setting perform the Set command and save the name. OSD Setting ..
  • Page 51 Home Position Preset Sets one of the currently configured preset positions as the home PTZF Setting position. Edit 001H 001H Home Position Execute Clear Status Execute Preset Recalls a saved preset location. PTZF Setting While in Sequence mode operation, the actual movement can be Edit 001H slower than the specified when moving the camera in the direction...
  • Page 52 setup Swing SEQ The Swing function commands the camera to move between 2 Main Menu selected locations, monitoring the route. Camera Setting Pan Swing : Sequence Setting Activates the Pan function for the Swing operation. P/T Setting OSD Setting Tilt Swing : Alarm Setting Activates the Tilt function for the Swing operation.
  • Page 53 Group SEQ Selecting Group SEQ recalls a group of multiple preset locations in Main Menu a consecutive manner. Up to 6 groups can be defined and up to 255 presets can be memorized for each group. Camera Setting Sequence Setting Setting : P/T Setting Using the joystick,enter desired preset numbers into the PSET...
  • Page 54: Ptz Trace

    Sequence Setting Representative Stop saving the Preset Protocol Model trace Swing SEQ PELCO-D/P KDB300A Ack, Iris Open Group SEQ SAMSUNG-E SSC-5000 OSD ON, Iris Open PTZ Trace Auto Run PANASONIC WV-CU161C OSD ON Power On Resume VICON V1300X-DVC Iris Open...
  • Page 55 Auto Run If there is no controller operation by the user for a certain time, the Main Menu sequence operation designated by the user will be executed. Camera Setting Mode : Sequence Setting HOME : Auto run Home Position (Refet to the Preset Menu.) P/T Setting PRESET : Auto run a selected preset number.
  • Page 56 setup Power On Resume and MD Dwell Time Power On Resume : Main Menu This is useful when the power is disconnected and reconnected Camera Setting due to power failures or other power interruptions. Sequence Setting If the camera was performing a sequence action prior to a power disconnection, the camera automatically resumes the P/T Setting action when the power is reconnected.
  • Page 57 P/T Setting Pan/Tilt Limit The moving ranges in the Pan/Tilt directions can be limited. Position : Selecting the Position menu brings up the following screen if it is Main Menu for the Pan Limit setting. Move the joystick left and right to select Camera Setting a movement range from the starting point to the end.
  • Page 58: Area Setting

    1x. Area Setting ON/OFF : Area 1 Cancels or activates the display function of selected areas. Area 2 Area 3  Area naming for SCU-9051/VAC/VAC1 Area 4 ..START POSITION END POSITION Area 1 Area Name ENTER: SET ESC: EXIT...
  • Page 59 Area Masking (SCU-2370/VAC/VAC1) If a monitoring location includes a highly private area, the area can be Main Menu selectively excluded from monitoring. Camera Setting Position : Sequence Setting As shown in the picture below, move the joystick to select the upper P/T Setting left corner and lower right corner of an area.
  • Page 60 setup Housing Load You can select a housing load of the camera module that will be Main Menu installed on the housing. Camera Setting  Sequence Setting Pan/Tilt movement speed depends on the camera module’s weight. For optimal speed control, set the weight of the camera module between 3 kg ~ 10 kg. P/T Setting OSD Setting Alarm Setting...
  • Page 61 Wiper (SCU-2370/VAC/VAC1) You can use Wiper to wipe out the front glass of the housing so as Main Menu to secure a clear view. Camera Setting To activate Wiper, set the menus below to your preference. Sequence Setting Pump Enable: P/T Setting Activate or deactivate the pump function.
  • Page 62 setup Prop. P/T (SCU-2370/VAC1) This commands the camera to change the Pan and Tilt speed Main Menu automatically according to the current zoom ratio. Moving the Camera Setting joystick clockwise (Tele) slows down and counterclockwise (Wide) accelerates the Pan and Tilt speed, allowing detailed adjustments. Sequence Setting Turning this “Off”...
  • Page 63 Image Hold (SCU-2370) While in Group Trace, this will display still image of the last preset Main Menu video until the camera moves to the next preset position. Camera Setting This is useful to help the screen observer keep sharp eyes and to monitor multiple locations within a network.
  • Page 64: Osd Setting

    setup OSD SETTING In this menu, you can configure the OSD (On Screen Display) settings. Camera ID : Main Menu Displays or hides Camera ID in the upper left of the screen. Camera Setting Camera Name : Sequence Setting P/T Setting Add a name to the camera.
  • Page 65: Alarm Setting

    ALARM SETTING Setting Up Alarm Input Alarm Enable : Main Menu On/Off : Enables or disables the Alarm function. Camera Setting Sequence Setting Enables selecting an Alarm Input method. P/T Setting OSD Setting - NO (Normally Open) Alarm Setting Initialize Status IN 1.2.3 IN 1.2.3...
  • Page 66: Alarm Output

    setup P(Priority) : Set the priority of Alarm Inputs. If more than one alarm is simultaneously activated, the alarm with the highest priority activates before the others. Once the alarm is canceled, the next highest priority alarm activates. SEQ. : Enables setting up a sequence action for the camera in response to an alarm.
  • Page 67: Aux Output

     Connecting the power connector and GND incorrectly to the NC/NO and COM ports may cause a short circuit and fi re, damaging the camera.  The maximum power capacity of the built-in relay is 30VDC/2A, 125VAC/0.5A, and 250VAC/0.25A. Operating the camera beyond the capacity may decrease the camera’s lifespan and damage it.
  • Page 68 setup IR Illuminator Settings (SCU-2370/VAC/VAC1) With IR Illuminator, you can control the red-infrared lighting. Main Menu Camera Setting On/Off : Sequence Setting Activate or deactivate IR Illuminator. P/T Setting Time: OSD Setting Operates the infrared illuminator for the time specifi ed by user Alarm Setting (1 second ~ 60 hours).
  • Page 69 INNER VER. : CAMERA VER. = V2.00_100527 Inner board F/W version MOTION VER. = V1.00_100726 DRIVER VER. : PROTOCOL = SAMSUNG-T CONTROLLER = S-9600 Display the DSP F/W version of the main board. INNER VER. = V1.00_100726 DRIVER VER. = V1.00_100726...
  • Page 70: Troubleshooting

    troubleshooting TROUBLESHOOTING If the product does not function properly, please see the below for trouble shooting. Problem Cause and Solution Page ► Check if the camera and peripheral devices are properly connected. Controller does not work. ► Verify the setups of ID, protocol, and baud rates. 18~21 ►...
  • Page 71 Problem Cause and Solution Page ► Check the White Balance. ► Adjust Color Menu in Image Adj. Picture’s colors are not good. ► Check if the cover or the camera lens is dirty or smudged. If it is, clean the dirt off. ►...
  • Page 72 troubleshooting Problem Cause and Solution Page ► Make sure that the camera and monitor are installed within the recommended distance. When coaxial communication is not available. ► Use the video amplifier equivalent to coaxitron if the recommended installation distance is exceeded. Check the Power cord’s by periods The Power cord’s coating has been damaged.
  • Page 73 product specifications PRODUCT SPECIFICATIONS SCU-2370N SCU-2370P Video Imaging Device 1/4” Exview HAD CCD Total Pixels 811(H) x 508(V) 795(H) x 596(V) Effective Pixels 768(H) x 494(V) 752(H) x 582(V) Scanning System 2:1 Interlace Synchronization Internal / Line Lock Internal / Line Lock Frequency H : 15.734KHz / V : 59.94Hz H : 15.625KHz / V : 50Hz...
  • Page 74: Product Specifications

    Communication RS-485, Coaxial Control ( SPC-300 Compatible ) Coax : Pelco-C ( Coaxitron ) Protocol RS-485: Samsung-T, Samsung-E, Pelco-D, Pelco-P, Panasonic, Vicon, Honeywell, AD, GE, Bosch Environmental Operating Temperature / -50°C ~ +50°C (-58°F ~ +122°F) / Less than 90% RH...
  • Page 75 Preset Accuracy Operational 1~255 Camera ID Off / On Motion Detection Coax : Pelco-C ( Coaxitron ) RS-485: Samsung-T, Samsung-E, Pelco-D, Pelco-P, Panasonic, Vicon, Honeywell, AD, Protocol GE, Bosch 3 In, 2 Out Alarm 1 Out Environmental Operating Temperature / -50°C ~ +50°C (-58°F ~ +122°F) / Less than 90% RH...
  • Page 76 Coaxial Control ( SPC-300 Compatible ) & RS-485 Communication Coax : Pelco-C ( Coaxitron ) Protocol RS-485: Samsung-T, Samsung-E, Pelco-D, Pelco-P, Panasonic, Vicon, Honeywell, AD, GE, Bosch Environmental Operating Temperature / Humidity -50°C ~ +50°C (-58°F ~ +122°F) / Less than 90% RH IP66...
  • Page 77 EXTERNAL DIMENSIONS (SCU-2370/VAC/9051) English - 77...
  • Page 78 product specifications INTERNAL DIMENSIONS (SCU-2370/VAC/9051) product specifications...
  • Page 79 EXTERNAL DIMENSIONS (SCU-VAC1) English - 79...
  • Page 80 product specifications INTERNAL DIMENSIONS (SCU-VAC1) product specifications...
  • Page 81 Wall Mount 72.1 153.7 496.8 Pedestal Mount 72.1 154.7 English - 81...
  • Page 82: Declaration Of Conformity

    DECLARATION OF CONFORMITY...
  • Page 83 MEMO...
  • Page 84 MEMO...
  • Page 85 MEMO...
  • Page 86 SAMSUNG TECHWIN AMERICA Inc. SAMSUNG TECHWIN EUROPE LTD. 100 Challenger Rd. Suite 700 Ridgefield Park, NJ 07660 Samsung House, 1000 Hillswood Drive, Hillswood Business Park Toll Free : +1-877-213-1222 Direct : +1-201-325-6920 Chertsey, Surrey, UNITED KINGDOM KT16 OPS Fax : +1-201-373-0124 TEL : +44-1932-45-5300, FAX : +44-1932-45-5325 www.samsungcctvusa.com...