Mitsubishi Electric DX-NT400E Operation Manual

Mitsubishi Electric DX-NT400E Operation Manual

Digital recorder rs-232c communication capacity
Hide thumbs Also See for DX-NT400E:

Quick Links

DIGITAL RECORDER
RS-232C COMMUNICATION CAPACITY
OPERATION MANUAL
MODEL
DX-NT400E
Contents
Connecting to a personal computer
Connecting to a personal computer
Connecting to a personal computer .....
Connecting to a personal computer
Connection via modem ...................................... 2
Direct connection ............................................... 2
RS-232C connector ........................................... 2
RS-232C cable ................................................... 2
Command codes
Command codes .....................................
Command codes
Command codes
RS-232C settings ........................................... 3
Command code system ................................. 3
Direct operation specification .......................... 3
Details of the numbers ...................................... 5
Command code .................................................. 5
• RS-232C [Direct operation specification]
General ............................................................. 5
.....................................
..................................... 3 3 3 3 3
.....................................
.....................................
..... 2 2 2 2 2
.....
.....
.....
• RS-232C Warning display ........................... 19
command form ........................................... 20
information system .................................... 21
Character code list ........................................... 22
Comment search
Comment search
Comment search ...................................
Comment search command code .............. 23
Characters can be used for
comment search .................................... 23
Sample operation ......................................... 23
...................................
...................................
................................... 23
...................................
23
23
23
23
Table of Contents
loading

Summary of Contents for Mitsubishi Electric DX-NT400E

  • Page 1: Table Of Contents

    DIGITAL RECORDER RS-232C COMMUNICATION CAPACITY OPERATION MANUAL MODEL DX-NT400E Contents Connecting to a personal computer Connecting to a personal computer ....2 2 2 2 2 Connecting to a personal computer Connecting to a personal computer ..Connecting to a personal computer ..
  • Page 2: Connecting To A Personal Computer

    Connecting to a personal computer I Connecting with a personal computer This unit can be remotely controlled from a PC equipped with a RS-232C connection. It is also possible to input com- ments from a PC for recording comment information along with the video. o Connection via modem Please use RS-232C Straight cable (9pin) to connect a modem to this unit.
  • Page 3: Command Codes

    Command codes I RS-232C settings Communication related settings of this unit are made in “MODE” and “SETTINGS” of the screen. Set the settings to the same values as the connecting modem or PC. When controlling this unit remotely from a PC, set “MODE” in the screen to “REMOTE A”, “RE- MOTE B”, or “REMOTE C”.
  • Page 4: False Operation Panel Command Type

    Command codes (continued) o False operation panel command type This system is used to specify operations of this unit from a PC as if operating the actual operation button of the remote control while viewing the output video. Each command corresponds to the operation button of the remote control. •...
  • Page 5: Details Of The Numbers

    Command codes (continued) o Details of the numbers : When the setting of DELIMITER on screen is set to CR, carriage return code (0DH) is input. If the setting is CR•LF, carriage return code (0DH) and line feed code (0AH) are input. : When the setting of DELIMITER on ...
  • Page 6 Command codes (continued) • RS-232C [Direct operation specification] operation setting system command form General (2/2) Commands name Commands Status Notes **** : Switcher Switcher SW**** ≤ RC ≥ EX,** SW**** ≥ 0100 : Single screen sequential 0101 : CH1 0102 : CH2 0103 : CH3 0104 : CH4 0180 : Zoom cancel...
  • Page 7: Time Date/Display Settings

    Command codes (continued) • RS-232C [Direct operation specification] menu setting system command form
  • Page 8: Mpx Display Settings

    Command codes (continued) • RS-232C [Direct operation specification] menu setting system command form Commands name Commands Status Notes SPLIT4 SCREEN ***** SPLIT4 : SETTING DW,***** ***** ≤ RC ≥ EX,** DW,***** ***** ≥...
  • Page 9: Motion Detection Settings

    Command codes (continued) • RS-232C [Direct operation specification] menu setting system command form Commands name Commands Status Notes DETECTION MASK ***** 00533-00724 : CH1 00725-00916 : CH2 SETTING DW,***** ***** ≤ RC ≥...
  • Page 10: Record Settings

    Command codes (continued) • RS-232C [Direct operation specification] menu setting system command form Commands name Commands Status Notes RECORD SETTING ***** 03703 : CH1 03704 : CH2 03705 : CH3 03706 : CH4 (PPS) DW,***** *****...
  • Page 11: Timer Program Settings

    Command codes (continued) • RS-232C [Direct operation specification] menu setting system command form (1/3) Commands name Commands Status Notes SELECTED PATTERN ***** : 03702 for timer recording DW,***** ***** ≤ RC ≥ ***** 00000 : P1 00001 : P2...
  • Page 12 Command codes (continued) • RS-232C [Direct operation specification] menu setting system command form (2/3) Commands name Commands Status Notes RECORD SETTING ***** A to D (PPS) DW,***** ***** ≤ RC ≥ 03982 : A-CH1 03983 : A-CH2 03984 : A-CH3...
  • Page 13 Command codes (continued) • RS-232C [Direct operation specification] menu setting system command form (3/3) Commands name Commands Status Notes ALARM SETTING A to D ***** ALARM SETTING A : (RECORD CAMERA) DW,***** ***** ≤...
  • Page 14: Initial Set Up/Information

    Command codes (continued) • RS-232C [Direct operation specification] menu setting system command form (1/2) Commands name Commands Status Notes HDD REPEAT REC ***** : 05709 ***** MAIN DW,***** ***** ≤ RC ≥ 00000 : OFF 00001 : ON 00002 : STANDBY...
  • Page 15 Command codes (continued) • RS-232C [Direct operation specification] menu setting system command form (2/2) Commands name Commands Status Notes ***** : 05724 HDD MAIN FULL DW,***** ***** ≤ RC ≥ ***** EX,** DW,***** *****...
  • Page 16: Search

    Command codes (continued) • RS-232C [Direct operation specification] menu setting system command form Refer to the “Playback” of [Direct operation specification] operation setting system command form “General” for search execution. Commands name Commands Status Notes ***** : Time to be searched TIME DATE SEARCH ...
  • Page 17: Other Settings

    Command codes (continued) • RS-232C [Direct operation specification] menu setting system command form (1/2) Commands name Commands Status Notes HDD SETTING ***** : 06401 ***** DR,***** ≤ RC ≥ 00000 : NORMAL 00001 : MIRRORING 00002 : PARTITION EX,**...
  • Page 18 Command codes (continued) • RS-232C [Direct operation specification] menu setting system command form (2/2) Commands name Commands Status Notes : Device ELAPSED TIME ? ≤ RC ≥ EX,** ,********** ≥ 0 : SYSTEM ********** : Elapsed time 0000000000-9999999999 (hour) : Error type : Camera number Registration of...
  • Page 19: Rs-232C Warning Display

    Command codes (continued) • RS-232C Warning display (1/2) Commands name Commands Status Notes (31) ••• * : 0 : No error display 1 : Error display Check of the warning WN1? ≤ RC ≥ (32) (31) : SYSTEM ERROR : TEMP display EX,** WN1*...
  • Page 20: Rs-232C [False Operation Panel] Command Form

    Command codes (continued) • RS-232C [False operation panel] command form Commands name Commands Status Notes POWER button (Power on/off) POWER KKP0 ≤ RC ≥ EX,** KKP0 ≥ : Error type REC/STOP RC ≥ REC/STOP button (Recording/Stop recording) KKR ≤ : Error type EX,** KKR ≥...
  • Page 21: Rs-232C State Transition Information System

    Command codes (continued) • RS-232C State transition information system Commands name Status Notes System mode **** EX,AA,**** ≥ 0100 : Power off 0101 : System change 0104 : Power on 0107 : menu 0109 : menu 010A : Device unusual situation 010B : Device initialize 010C : Device reconstruction 0110 : Auto set up...
  • Page 22: Character Code List

    Command codes (continued) o Character code list (When LANGUAGE is set to other than “PìCCKàâ”.) (Space) Character " & Character code 00012 00032 00033 00034 00035 00036 00038 00039 00040 00041 00042 00043 00037 Character < > Character code 00044 00058 00059 00060...
  • Page 23: Comment Search Comment Search

    Comment search Characters (character strings) input from a PC connected to this unit by RS-232C connection can be recorded as comments along with the video/audio. Recorded comments can be displayed during playback. Furthermore, you can specify the comments and search the scene of which the specified comments are recorded. I Comment search command code Commands name Commands...

Table of Contents