Table of Contents
Available languages

Available languages

GE Energy
WattStation
Wall Mount
User Manual

Chapters

Table of Contents
loading

Summary of Contents for GE WattStation

  • Page 1 GE Energy ™ WattStation Wall Mount User Manual...
  • Page 2: Table Of Contents

    (Wall) (“this Warranty”) ............. 11 WattStation should be installed only a licensed contractor, and/or a licensed electrician in accordance with all applicable state, local and national electrical codes and standards. WattStation should be inspected by a qualified inspector prior to initial use. Under no circumstances will compliance with the information in this manual relieve the user of his/her responsibility to comply with all applicable codes or safety standards.
  • Page 3: Grounding Instructions

    Do not use this product if the enclosure or the charging connector is broken, cracked, open, or show any other indication of damage. This document provides instructions for the wall mounted WattStation and should not be used for any other product. Before installing WattStation you should review this manual carefully and consult with a licensed contractor, licensed electrician, or trained installation expert to ensure compliance with local building codes, climate conditions, safety standards and state and local electrical codes.
  • Page 4: Installation

    WattStation™ Wall Mount User Manual Recommended mounting hardware for wood studs are 1/4" x 2" hex head lag bolts. • Recommended mounting hardware for concrete walls are 1/4" x 1-3/4" concrete hex screws or 1/4" x 1-7/8" concrete anchors WARNING: Danger of electrical shock or injury. Turn OFF power at the panelboard or load center before working inside the equipment or removing any component.
  • Page 5 NEC 625.29. For ADA compliant installation, refer to ADA accessibility guidelines, section 4.2 Step 4: Slide WattStation unit onto the mounting bracket, ensuring that the opening in the back plate bracket aligns with the tab on the wall mount bracket by first carefully disconnecting the wires connecting the front cover.
  • Page 6 WattStation™ Wall Mount User Manual Step 5: Lock the WattStation unit onto the mounting bracket using the provided key Step 5: Unwrap the plug-in cord and plug into the wall receptacle Step 6: Lock weatherproof receptacle cover (not supplied with WattStation) GE Energy ©2012 GE Company All Rights Reserved...
  • Page 7: Hardwired Version

    24” minimum for outdoor use. The distance to the top of the unit should be 48” maximum for all applications per NEC 625.29. For ADA compliant installation, refer to ADA accessibility guidelines, section 4.2. Make sure the bracket is aligned so that power wire will fit through the WattStation enclosure holes (for back-entry wiring only).
  • Page 8 Press and hold the button on top of the connector handle and pull the handle away from the vehicle inlet socket. The charge status indicator light will turn off. Replace the connector handle into the WattStation holder by pushing the connector into the inlet. This will ensure the connector is locked with the metal inlet of the WattStation holder.
  • Page 9: Basic Features

    WattStation can be turned on by pressing in the On/Off pushbutton. When on, the LED ring around the connector will glow white. WattStation can be turned off at any time by pressing the On/Off button again. The LED ring will turn off. 3.3 Connecting and Disconnecting to Vehicle Connect to Vehicle When the connector is seated in the WattStation holder, press and hold the button on the connector handle and pull away from the holder until it is fully removed.
  • Page 10 Internal 20mA CCID with auto-re-closure, does not require a GFCI in service panel Ground Monitoring Ensures ground is present between vehicle and WattStation, and between WattStation and load center Standby Power 0 W when not charging and turned off by...
  • Page 11: Technical Information

    Once a ground fault is detected, WattStation will stop charging the vehicle and the fault status indicator will turn red. The WattStation will automatically reset after 15 minutes or if the EV connector is disconnected from the vehicle.
  • Page 12 Hardware arises and a valid claim is received within the Warranty Period, your sole and exclusive remedy will be for GE, in its sole discretion and to the extent permitted by law, to (1) repair the defect in the Hardware at no charge, using new parts or refurbished parts, or (2) exchange the Hardware with new or refurbished hardware that is functionally equivalent to the original Hardware, (the repaired Hardware and the exchanged hardware are called the “Remedied Hardware”).
  • Page 13 If any provision is held to be illegal or unenforceable, the legality or enforceability of the remaining provisions shall not be affected or impaired. EXCEPT AS PROVIDED IN THIS WARRANTY AND TO THE MAXIMUM EXTENT PERMITTED BY LAW, GE IS NOT RESPONSIBLE FOR DIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM ANY BREACH OF WARRANTY OR CONDITION, OR UNDER ANY OTHER LEGAL THEORY, INCLUDING BUT NOT LIMITED TO LOSS OF USE;...
  • Page 14 WattStation is a trademark of General Electric Company. Information provided is subject to change without notice. Please verify all details with GE. All Values are design or typical values when measured under laboratory conditions and GE makes no warranty or guarantee, express or implied, that such performance will be obtained under end- use conditions.
  • Page 15 GE Energy ™ WattStation Wall Mount Manual de usuario  ...
  • Page 16 4. GARANTÍA LIMITADA DE GE WattStation (Pared) ....................26 WattStation debe ser instalado sólo por un contratista con licencia, y / o con un electricista calificado de acuerdo con todas las leyes, locales, nacionales y las normas de los códigos eléctricos.
  • Page 17: Instrucciones De Puesta A Tierra

    1.2 Instrucciones de conexión a tierra WattStation debe estar conectado a un sistema de tierra centralizado. Los conductores de tierra que entran al WattStation deberán estar conectados a la barra de tierra del equipo en el interior del cargador. Las conexiones al WattStation deberán cumplir con todos los códigos eléctricos y ordenanzas.
  • Page 18 • de 40A aguas arriba, ubicado ya sea en un centro de carga o tablero de alumbrado La distancia entre el receptáculo de alimentación de pared y el WattStation debe ser inferior a un (1) • El Toma de corriente de pared deberá tener cubierta de intemperieLos tornillos recomendados para el •...
  • Page 19: Instalación

    ADA, refiérase a las directrices de accesibilidad de la ADA,en la sección 4.2 Paso 4: Deslice la unidad WattStation en el soporte de montaje, asegurando que la abertura en el soporte de la placa posterior se alinea con la pestaña en el soporte de montaje en pared.
  • Page 20: Versión Cableada

    WattStation™ Wall Mount User Manual Paso 6: Desenrolle el cable de la versión Plug-in y enchúfelo en el receptáculo de la pared Paso 7: Cierre la cubierta del Receptáculo resistente a la intemperie (no suministrado con WattStation) 2.3 Versión Cableada 2.3.1 Antes de la Instalación...
  • Page 21: Instalación

    Asegúrese de que un circuito dedicado, capaz de suministrar 30A a 208-240 VAC, está disponible • La alimentación de energía debe tener el neutro aterrizado para que el WattStation funcione • correctamente.
  • Page 22: Manual De Usuario

    Paso 6: Introducir los cables de alimentación y cables de tierra a través de los orificios del gabinete WattStation. Deslice el WattStation en el soporte de montaje, asegurando que la abertura en el soporte de la placa posterior esté alineada con la pestaña en el soporte de montaje en pared.
  • Page 23: Encendido Y Apagado

    3.2 Encendido y Apagado El WattStation se puede encender pulsando en el botón On / Off. Cuando está activado, el anillo de LED alrededor del conector se ilumina blanco. El WattStation se puede apagar en cualquier momento pulsando el botón On / Off de nuevo. El anillo de LED se apagará..
  • Page 24: Información Técnica

    WattStation™ Wall Mount User Manual 3.4 Información Técnica **WattStation determina el consumo máximo de energía. EV determina el consumo de energía real. Cumple SAE Nivel II por J1772 Interfaz del Vehículo Conector SAE J1772 EV Longitud del cable Cable de 16 ' Máxima potencia de salida de carga CA**...
  • Page 25: Remplazo De Fusibles

    Cuando el indicador de fallo se ilumina en rojo,el WattStation indica una falla. Falla a tierra: El WattStation puede detectar la presencia de fallas a tierra con un umbral de 15 a 20 mA durante el ciclo de carga. Una vez que una falla a tierra es detectado,El WattStation dejará de cargar el vehículo y el indicador de estado de fallo se encenderá...
  • Page 26: Garantía Limitada De Ge Wattstation

    El uso del WattStation GE (pared) empacadocon este manual de usuario(el "equipo"), el registro del equipo en línea , o el envío de su tarjeta de registro.Las obligaciones de GE por garantía de este equipo se limita a los términos establecidos en esta Garantía Limitada y está limitada y sujeta a las exclusiones y limitaciones que figuran a continuación.
  • Page 27 (i) Los números de serie de GE que han sido eliminados o borrados(j) los daños causados por o a través de la red en la que se utiliza el equipo, incluyendo pero no limitado a, cualquier intrusión en línea o ataque.
  • Page 28 WattStation is a trademark of General Electric Company. Information provided is subject to change without notice. Please verify all details with GE. All Values are design or typical values when measured under laboratory conditions and GE makes no warranty or guarantee, express or implied, that such performance will be obtained under end- use conditions.

Table of Contents