Fujitsu ETERNUS DX100 S3 Operation Manual

Fujitsu ETERNUS DX100 S3 Operation Manual

Disk storage system
Hide thumbs Also See for ETERNUS DX100 S3:
Table of Contents
P3AM-7662-04ENZ0
FUJITSU Storage
ETERNUS DX100 S3/DX200 S3
Disk storage system
Operation Guide (Basic)
Table of Contents
loading

Summary of Contents for Fujitsu ETERNUS DX100 S3

  • Page 1 P3AM-7662-04ENZ0 FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic)
  • Page 2 This page is intentionally left blank.
  • Page 3: About This Manual

    Preface Fujitsu would like to thank you for purchasing our FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system (hereinafter referred to as ETERNUS DX). The ETERNUS DX is designed to be connected to Fujitsu servers (Fujitsu M10, PRIMEQUEST, or PRIMERGY) or non-Fujitsu servers.
  • Page 4: Naming Conventions

    Windows Server 2008 R2 for Itanium-Based Systems ® ® Microsoft Windows Server 2008 HPC Edition ® ® Microsoft Windows Server 2008 R2 HPC Edition FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 5 This indicates supplementary and reference information. ■ Abbreviations Used in This Manual "ETERNUS DX100 S3" refers to the FUJITSU Storage ETERNUS DX100 S3 Disk storage system and "ETERNUS • DX200 S3" refers to the FUJITSU Storage ETERNUS DX200 S3 Disk storage system.
  • Page 6 The black "Must Do..." circle indicates actions that must be taken. The required ac- tion is both illustrated inside the black disk and written above it (e.g. Unplug). FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED...
  • Page 7 - Be careful that no liquid seeps into the ETERNUS DX when using cleaners, etc. - Do not use alcohol or other solvents to clean the ETERNUS DX. Warning layout ribbon FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 8: Table Of Contents

    2.2 Using the FUNCTION Button ......................51 Chapter 3 Storage System Monitoring 3.1 Checking LED Status ........................53 3.2 Displaying Status via ETERNUS Web GUI..................53 FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 9 6.1 Periodic Backup.......................... 103 6.2 Maintenance Service ........................103 6.2.1 Maintenance Support Period ..........................103 6.2.2 Related Service ..............................103 Chapter 7 Troubleshooting 7.1 Check List ........................... 104 FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 10 Table of Contents 7.2 Required Information for Inquiries ..................... 112 FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 11 ON Position (Marked "|") of the PSU Switch on a Power Supply Unit ............46 Figure 2.6 OFF Position (Marked "¡") of the PSU Switch of a Power Supply Unit ............47 FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 12 List of Figures Figure 3.1 ETERNUS Web GUI Screen .........................53 Figure 3.2 Event Notification ............................56 Figure 3.3 Audit Log..............................56 FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 13 General Status of ETERNUS CLI .........................54 Table 4.1 Volume Formatting Time (Disk) .......................57 Table 4.2 Rebuild Process Time (Disk) ........................58 Table 4.3 Copyback Process Time (Disk) ........................58 FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 14: Chapter 1 Component Name/Led Name

    This section provides the names of the components in the front of a controller enclosure. ■ 2.5" Type Figure 1.1 Front View of a 2.5" Type Controller Enclosure Operation panel 2.5" drive Flange cover FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 15: Rear

    Figure 1.3 Rear View of a Controller Enclosure (When Only One Controller is Installed) Controller (CM#0) Cover Remove this when installing an additional controller (optional). Power supply unit (PSU#0) Power supply unit (PSU#1) FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 16: Figure 1.4 Rear View Of A Controller Enclosure (When Two Controllers Are Installed)

    Figure 1.4 Rear View of a Controller Enclosure (When Two Controllers are Installed) Controller (CM#0) Controller (CM#1) Power supply unit (PSU#0) Power supply unit (PSU#1) FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 17: Components (Front)

    The installation location of the controller enclosure is identified (blinks blue) according to the instruction that is issued from ETERNUS Web GUI or ETERNUS CLI. FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 18 *1: When the READY LED and the FAULT LED are both on at the same time, an error has occurred while the Unified configuration is starting up. FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED...
  • Page 19: Figure 1.6 2.5" Drives

    DRIVE FAULT LED Figure 1.9 Drive Slot Numbers (3.5" Type Controller Enclosure) Slot#8 Slot#9 Slot#10 Slot#11 Slot#4 Slot#5 Slot#6 Slot#7 Slot#0 Slot#1 Slot#2 Slot#3 FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 20: Components (Rear)

    12 10 Figure 1.11 Controllers 14 15 PWC port This port is used to connect a power synchronization unit with an RS232C cable. FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 21: Table 1.3 Status And Meanings Of Each Led (Controller)

    • (blinks amber) MASTER The controller is set as a Master CM. (green) CA FAULT The host interface is in error status. (amber) FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 22: Figure 1.12 Fc Interface (Installed In A Controller)

    Host interface port (CA#0, Port#0) Host interface port (CA#0, Port#1) Host interface (CA#1) Host interface port (CA#1, Port#0) Host interface port (CA#1, Port#1) FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 23: Figure 1.13 Host Interface For Fc Cable Connection (Installed In A Controller)

    Host interface port (CA#0, Port#0) Host interface port (CA#0, Port#1) Host interface (CA#1) Host interface port (CA#1, Port#0) Host interface port (CA#1, Port#1) FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 24: Figure 1.15 Iscsi 1Gbit/S Interface (Installed In A Controller)

    Host interface port (CA#0, Port#0) Host interface port (CA#0, Port#1) Host interface (CA#1) Host interface port (CA#1, Port#0) Host interface port (CA#1, Port#1) FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 25: Figure 1.17 Ethernet 1Gbit/S Interface (Installed In A Controller)

    Host interface (CA#1) Host interface port (CA#1, Port#0) Host interface port (CA#1, Port#1) Host interface port (CA#1, Port#2) 10. Host interface port (CA#1, Port#3) FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 26: Figure 1.18 Power Supply Unit (Controller Enclosure)

    FAN FAIL The power supply unit or the fan in the power supply unit is in er- (amber) ror status. FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 27: 2.5"/3.5" Type Drive Enclosure

    2.5" drive Flange cover ■ 3.5" Type Figure 1.20 Front View of a 3.5" Type Drive Enclosure Operation panel 3.5" drive Flange cover FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 28: Rear

    Figure 1.22 Rear View of a Drive Enclosure (When Two I/O Modules are Installed) I/O module (IOM#0) I/O module (IOM#1) Power supply unit (PSU#0) Power supply unit (PSU#1) FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 29: Components (Front)

    ETERNUS Web GUI or ETERNUS CLI. FAULT The drive enclosure is in error status. (amber) POWER DC power is supplied to the drive enclosure. (green) FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 30: Figure 1.24 2.5" Drives

    LED. Figure 1.24 2.5" Drives DRIVE READY LED DRIVE FAULT LED Figure 1.25 Drive Slot Numbers (2.5" Type Drive Enclosure) FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 31: Components (Rear)

    This section describes the I/O modules and the power supply units in the rear of the drive enclosure. ■ I/O Modules The I/O module is a component that controls how the controller and the drives interact. FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 32: Figure 1.28 I/O Module (2.5" / 3.5" Type Drive Enclosure)

    ETERNUS Web GUI or ETER- NUS CLI. FAULT The I/O module is in error status. (amber) FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 33: Figure 1.29 Power Supply Unit (2.5"/3.5" Type Drive Enclosure)

    FAN FAIL The power supply unit or the fan in the power supply unit is in er- (amber) ror status. FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 34: High-Density Drive Enclosure

    This section provides the names of the components in the rear of a high-density drive enclosure. Figure 1.31 Rear View of a High-density Drive Enclosure FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED...
  • Page 35: Components (Front)

    ETERNUS Web GUI or ETERNUS CLI. FAULT The drive enclosure is in error status. (amber) POWER DC power is supplied to the drive enclosure. (green) FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 36: Figure 1.33 Disk Activity Panel (Dap)

    • The drive is in error status. (amber) In response to commands from ETERNUS CLI, the location of • the drive is identified. FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 37: Components (Internal)

    Figure 1.34 Drives for High-density Drive Enclosures Figure 1.35 Drive Slot Numbers for High-density Drive Enclosures Rear Front FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 38: Components (Rear)

    The ports to connect the cables are indicated. This occurs while a (blinks amber) drive enclosure is being added. READY The I/O module is in normal status. (green) FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 39: Figure 1.37 Fan Expander Module

    The power supply unit transforms input AC power from a power socket to DC power and supplies power to each component. Each power supply unit contains fans. FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 40: Figure 1.38 Power Supply Unit (High-Density Drive Enclosure)

    FAN FAIL The power supply unit or the fan in the power supply unit is in er- (amber) ror status. FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 41: Power Distribution Units (For Regions Other Than Emea&I)

    The 1U power distribution unit has four outlets and two inlets. ■ Power distribution unit for DX100 S3/DX200 S3 (AC200-240V, 1U 4Outlets) Figure 1.39 Power distribution unit for DX100 S3/DX200 S3 (AC200-240V, 1U 4Outlets) Main line switch This turns on and off the power distribution unit.
  • Page 42: Power Distribution Units (2U)

    ■ Power distribution unit for DX100 S3/DX200 S3 (AC200-240V, 2U, 12Outlets) There are 12 outlets. Figure 1.40 Power distribution unit for DX100 S3/DX200 S3 (AC200-240V, 2U, 12Outlets) Main line switch This turns on and off the power distribution unit. Outlet (OUTPUT) This is a socket (IEC60320 C13) for outgoing power supply.
  • Page 43: Chapter 2 Basic Operation

    ● For 1U Figure 2.1 ON Position (Marked "|") of the Main Line Switches on a 1U Power Distribution Unit Main line switch FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 44: Figure 2.2 On Position (Marked "|") Of The Main Line Switches On A 2U Power Distribution Unit

    ● For 1U Figure 2.3 OFF Position (Marked "¡") of the Main Line Switches on a 1U Power Distribution Unit Main line switch FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 45: Figure 2.4 Off Position (Marked "¡") Of The Main Line Switches On A 2U Power Distribution Unit

    When turning the main line switch to ON (marked "|") right after turning the main line switch to OFF (marked "¡"), turn it back to ON (marked "|") after the POWER LED of the power supply unit has turned off completely. FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 46: Switching On And Off The Psu Switch On The Power Supply Unit

    For the drive enclosure, the POWER LED on the power supply unit emits green lights and the fan revolves at • high speed for 30 seconds. Drive enclosure Controller enclosure Power supply unit (PSU#0) Power supply unit (PSU#1) POWER FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 47: Figure 2.6 Off Position (Marked "¡") Of The Psu Switch Of A Power Supply Unit

    Figure 2.6 OFF Position (Marked "¡") of the PSU Switch of a Power Supply Unit Power supply unit (PSU#0) Power supply unit (PSU#1) Check that the POWER LED of the power supply unit is off. FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 48: Powering On

    This section explains how to use the Power switch to turn on the ETERNUS DX. For other procedures, refer to the related manuals. FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 49: Powering Off

    The following methods can be used to turn off the power by linking with the server. Via the power synchronized unit • Use the power synchronized unit to turn off the ETERNUS DX. FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 50 The ETERNUS DX power is turned off. The POWER LED of the controller enclosure and the POWER LEDs of the drive enclosures are turned off. FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED...
  • Page 51: Using The Function Button

    Use the pin to push down the FUNCTION button for three seconds. The ETERNUS DX is in maintenance status when the MAINTENANCE LED is green. FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED...
  • Page 52 Use the pin to push down the FUNCTION button for three seconds. The MAINTENANCE LED turns off, which indicates that the ETERNUS DX is no longer in maintenance sta- tus. Attach the flange cover. FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 53: Chapter 3 Storage System Monitoring

    The status of the ETERNUS DX and the usage status of RAID groups, TPPs, and SDPs can be checked in the Overview screen of ETERNUS Web GUI. Figure 3.1 ETERNUS Web GUI Screen Table 3.1 shows the general status. FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 54: Displaying Status Via Eternus Cli

    An abnormality is detected and access from the host cannot be received. Subsystem Down The ETERNUS DX cannot be used. Change Assigned CM CM hot expansion recovery is required. FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 55: Event Notification

    For the notified Syslog messages, refer to "Message List". ■ Remote Support The information for errors that occur in the ETERNUS DX is notified to the remote support center. FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 56: Audit Log

    Change settings the process time, ↓ Log out the process details, and the process results Audit log System administrator ETERNUS DX Syslog server FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 57: Chapter 4 Process Time (Estimated)

    *1: The value shows the time required for volume formatting when the volume capacity is 100GB and there is no server I/O. The time that is required depends on the type and configuration of the disk. FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED...
  • Page 58: Rebuild/Copyback Process Time

    *1: The value shows the copyback process time when the volume capacity is 100GB and there is no server I/O. The time that is required depends on the type and configuration of the disk. FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED...
  • Page 59 Note that RAID group performance (throughput) may be reduced when a rebuild, copyback, or redundant copy is being performed in the target RAID group. FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED...
  • Page 60: Chapter 5 Expansion Functions

    Contact your sales representative or maintenance engineer if drives that are instal- led by default need to be uninstalled or moved to another slot. 5.1.1 Installable Drives For installable drives, refer to "Product List". FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 61: Drive Handling Instructions

    Failure to discharge static elec- tricity may cause device failure. Leave the drive in its package until ready to install it. • FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 62: Additional Drive Installation Procedure

    If components are installed in a way other as described in this section, damage and/or device failure or electrical shock may occur. Do Not • Do not install drives that are for use in other devices. FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 63 Keep the removed dummy drive units in a safe place where they will not be lost. Install the new drive. Press the catch on the drive lock lever to unlock it. Lock lever FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 64 In the [Drives] screen of [Component] on the ETERNUS Web GUI screen, check that the added drives have been recognized. Set up RAID groups, volumes, hot spares, and host affinity settings on the new drives, as required. FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 65 Insert the drive all the way into the slot, making sure that it is firmly seated and that the lock lever is still left open. FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED...
  • Page 66 ETERNUS DX are in normal status. Wear a wrist strap or touch a metal part to discharge the human body's natural static electricity. FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED...
  • Page 67 Remove the four M5 screws that are used to fasten the high-density drive enclosure in the rack pillar. (Rack pillar: rear) M5 screws (Rack pillar: front) M5 screws FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 68 Push the two catches on the top board in the direction of the arrows to unlock them. Catch FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 69 Pull the catch on the lock lever of the dummy drive unit to unlock the lock lever, and then open the lock lever upward. Pull up the dummy drive unit in a straight direction. FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 70 Insert the drive all the way into the slot, making sure that it is firmly seated and that the lock lever is still left open. Hold the drive with both hands to protect against jarring. • FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 71 In the [Drives] screen of [Component] on the ETERNUS Web GUI screen, check that the added drives have been recognized. Set up RAID groups, volumes, hot spares, and host affinity settings, as required. FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 72: Installing Additional Drive Enclosures

    To avoid this, allow the packed drive enclosure sufficient time in the warmer place (one hour for each 15°C of temperature difference) to adapt to the new tempera- ture. FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 73 • ing it down. Do not stack the drive enclosures. • Do not knock or drop the drive enclosure on hard objects. • FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 74: Additional Drive Enclosure Installation Procedure

    To disconnect the mini SAS HD cables between enclosures, hold the tab and then pull out the connector. Pull-tab FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 75 Display the [Add Drive Enclosure] screen. In the [Storage] screen of [Component], click [Add Drive Enclosure] in [Action]. The [Add Drive Enclosure] screen appears. FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 76 A screen that shows which DE-ID the additional drive enclosure is to be connected to, the type of drive enclosure that is to be added, and the procedure to add the drive enclosure is displayed. FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED...
  • Page 77 (Front view of rack pillar) M5 screw Rack rail (right) The M5 screw positions for the rack rails are determined by the drive enclosure base line. FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 78 Failure to do so may cause injury. FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED...
  • Page 79 Right front side of the drive enclosure Upper right rear side of the drive enclosure DE_No. label The DE_No. labels are supplied with the ETERNUS DX. FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 80 Rack rail (left) "Left" is on the exterior [Right] Rack rail (right) "Right" is on the exterior (Rack pillar: front) (Rack pillar: rear) FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 81 M4 screw (right) (Rack pillar: front) The M4 screw positions for the rack rails are determined by the high-density drive enclo- sure base line. FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 82 Insert the M5 screws in the seventh holes above the base line to fasten the stopper brackets. High-density drive enclosure Front [Left] [Right] 7th hole 7th hole (M5 screw) (M5 screw) High-density drive enclosure base line Rack rail FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 83 Install the high-density drive enclosure in the rack. For safety and stability, use a lifter to install or remove high-density drive enclosures in the rack. FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 84 To attach the cable management arm, place the arm in the bracket on the rear of the high- density drive enclosure. After placing the arm in the bracket, firmly attach the arm with the pin. Cable management arm FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 85 Check the connection destination of the cables between enclosures. The connectors on the cable with the "l" symbol are connected to the DI (IN) ports on the added • enclosure. FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 86 Each enclosure has two (or four) power supply units. Make sure that power cords are connected to all the power supply units. Connect the power cord plugs to the power inlets of the power supply units. FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 87 Configuration of IOM#0 in the drive enclosure that is to be added and the power supply units in the system is performed. When the configuration process is complete, the [Disable IOM#1] screen appears. FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 88 In the IOM#1 disconnection screen, click the [Next>>] button. The process to disconnect IOM#1 starts. When the disconnection process is complete, the [Detach Cable] screen appears. FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 89 Remove from here Drive enclosure 1 Remove from here Controller 1 Controller enclosure Click the [Next >>] button. The [Connect Cable] screen appears. FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 90 Drive enclosure 1 Connect here Controller enclosure Controller 1 Click the [Next >>] button. The [Enable IOM#1] screen appears. FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 91 (OUT) port blink on and off. Drive enclosure 2 (drive enclosure Connect that is to be added) here Connect here Drive enclosure 1 FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 92 To install more additional drive enclosures, repeat Step 1 Step Install the drives. For details on drive installation, refer to "5.1.3 Additional Drive Installation Procedure" (page 62). FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 93: Installing Long Wave Sfp+ Modules (16Gbit/S)

    To avoid this, allow the packed SFP+ modules sufficient time in the warmer place (one hour for each 15°C of temperature difference) to adapt to the new tempera- ture. FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 94: Long Wave Sfp+ Modules (16Gbit/S) Installation Procedure

    Note that a Short wave SFP+ module (16Gbit/s) is displayed as "16G SFP+(MMF)" in the "SFP Type" field. Turn off the ETERNUS DX. Refer to "2.1.4 Powering Off" (page 49) for details on how to turn off the ETERNUS DX. FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 95 Connect the FC cable that is disconnected in Step Connect the FC cable connector to the FC port on the Long wave SFP+ module (16Gbit/s). FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 96: Adding Servers

    Enter the name of the RAID group that is to be registered and select "Automatic" or "Manual" for "Create Mode". When "Automatic" is selected, the settings for "Automatic Setting" are displayed. FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 97: Volume Creation

    Click the [OK] button. The volume is created and the registration completion screen appears. Click the [Done] button. The screen display returns to the [Volumes] screen. FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 98: Connection Setup

    Register a host in a host group, and then click the [Add] button. A confirmation screen appears. Click the [OK] button. The host group is added and the registration completion screen appears. FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 99 The CA port group is created and the setting completion screen appears. Click the [Done] button. The screen display returns to the [CA Port Group] screen. FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 100 The LUN group is added and the setting completion screen appears. Click the [Done] button. The screen display returns to the [LUN Group] screen. FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 101 [Create] button. A confirmation screen appears. Click the [OK] button. The host affinity is created and the registration completion screen appears. FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 102 Chapter 5 Expansion Functions Adding Servers Click the [Done] button. The screen display returns to the [Connectivity] screen. FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 103: Chapter 6 Maintenance

    If a possible error that may occur is detected or an error occurs when remote support service is used, the con- tents of events are automatically sent to the remote support center and notified to the user. FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED...
  • Page 104: Chapter 7 Troubleshooting

    Has there been a recent main power failure? If the Power Resume function is enabled, the ETERNUS DX turns on automatically after the power is re- stored. FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 105 Press the controller enclosure's Power switch for four seconds or more to turn off the ETERNUS DX. Drive enclosures with no mini SAS HD cable between enclosures connected will remain on. FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED...
  • Page 106 Protection (Shield) function works and how to check whether it is running, refer to "Design Guide (Basic)". If none of these resolve the problem, contact your maintenance engineer. FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 107 Note that the settings (network environment settings and firewall settings) for all of the LAN ports are initialized after the following procedure is performed. Remove the flange cover of the controller enclosure. FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 108 NUS DX does not respond to SNMP access. Check whether each service can connect to the ETERNUS DX. If it cannot connect, contact your maintenance engineer. FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 109 Check if an error occurs in a path by using a path management tool such as ETERNUS Multipath Manager. • Refer to the relevant manuals and take the required actions. FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 110 Turn off the server where the LAN card is to be replaced. Replace the LAN card. For details on the replacement procedure, refer to the relevant documentation for the LAN card. FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 111 Set the SAS address, host affinity, and other settings of the new SAS card by referring to the information recorded in Step After completing the settings, confirm that access from the server is available. FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED P3AM-7662-04ENZ0...
  • Page 112: Required Information For Inquiries

    ETERNUS Web GUI. For details on obtaining the log/dump information, refer to "Web GUI User's Guide (Settings)". FUJITSU Storage ETERNUS DX100 S3/DX200 S3 Disk storage system Operation Guide (Basic) Copyright 2014 FUJITSU LIMITED...
  • Page 113 However, Fujitsu shall assume no responsibility for any operational problems as the result of errors, omissions, or the use of information in this manual. Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information •...

This manual is also suitable for:

Eternus dx200 s3

Table of Contents