  • Page 1 Allegiant Keyboards LTC 8555 Series Instruction Manual...
  • Page 3: Table Of Contents

    Important Notices Customer Support and Service Unpacking Keyboard Models Description Installation General LTC 8555/00 and LTC 8555/01 (standard keyboard) Installation LTC 8555/02 and LTC 8555/03 (RS-232 Protocol Model) Installation 5.3.1 General 5.3.2 Keyboard Number Assignments when Using RS-232 Model Keyboards 5.3.3 Allegiant System Command Scripts for RS-232 Model Keyboards 5.3.4...
  • Page 4 7.5.17 Programming a SalvoSwitching Camera Sequence Keyboard User Functions Error Messages Data Interface and Cable Pinouts Troubleshooting General Local Keyboard Test -- Keyboard User Function 1 Icon Translator Chart F.01U.127.290 | 2.0 | 2009.03 Instruction Manual Bosch Security Systems, Inc.
  • Page 5: Safety

    ON/OFF switch is in the ON position. The power cord is the main power disconnect device for switching off the voltage for all units. Bosch Security Systems, Inc. Instruction Manual F.01U.127.290 | 2.0 | 2009.03...
  • Page 6 17. Attachments, changes or modifications - Only use attachments/accessories specified by the manufacturer. Any change or modification of the equipment, not expressly approved by Bosch, could void the warranty or, in the case of an authorization agreement, authority to operate the equipment.
  • Page 7: Safety Precautions

    Connect outdoor equipment to the unit's inputs only after this unit has had its grounding plug connected to a grounded outlet or its ground terminal is properly connected to a ground source. Bosch Security Systems, Inc. Instruction Manual F.01U.127.290 | 2.0 | 2009.03...
  • Page 8 Please dispose of these units at an environmentally compatible recycling facility, per European Directive 2002/96/EC. Environmental statement - Bosch has a strong commitment towards the environment. This unit has been designed to respect the environment as much as possible.
  • Page 9 Because the ISDN circuits are treated like telephone-network voltage, avoid connecting the SELV circuit to the Telephone Network Voltage (TNV) circuits. Video loss - Video loss is inherent to digital video recording; therefore, Bosch Security Systems cannot be held liable for any damage that results from missing video information. To minimize the risk of lost digital information, Bosch Security Systems recommends multiple, redundant recording systems, and a procedure to back up all analog and digital information.
  • Page 10 : « How to Identify and Resolve Radio-TV Interference Problems ». Cette brochure est disponible auprès du U.S. Government Printing Office, Washington, DC 20402, États-Unis, sous la référence n° 004-000-00345-4. F.01U.127.290 | 2.0 | 2009.03 Instruction Manual Bosch Security Systems, Inc.
  • Page 11 UL MAKES NO REPRESENTATIONS, WARRANTIES, OR CERTIFICATIONS WHATSOEVER REGARDING THE PERFORMANCE OR RELIABILITY OF ANY SECURITY OR SIGNALING- RELATED FUNCTIONS OF THIS PRODUCT. Copyright This user guide is the intellectual property of Bosch Security Systems, Inc. and is protected by copyright. All rights reserved. Trademarks All hardware and software product names used in this document are likely to be registered trademarks and must be treated accordingly.
  • Page 12: Customer Support And Service

    | Safety Allegiant Keyboards Customer Support and Service If this unit needs service, contact the nearest Bosch Security Systems Service Center for authorization to return and shipping instructions. Service Centers Repair Center Telephone: 800-566-2283 Fax: 800-366-1329 E-mail: [email protected] Customer Service...
  • Page 13: Unpacking

    With a few minor exceptions, general operation is identical for all models. Although the LTC 8555/00 and LTC 8555/01 are compatible with Allegiant systems of any age, the LTC 8555/02 and LTC 8555/03 models require Allegiant CPU firmware version 7.6 or higher.
  • Page 14: Description

    Easy to read LED displays show real time camera, monitor, and communication status, as well as error messages. Keyboards also provide audible and visual indications of system alarm conditions. A built-in diagnostic mode makes troubleshooting of suspected fault conditions easy. F.01U.127.290 | 2.0 | 2009.03 Instruction Manual Bosch Security Systems, Inc.
  • Page 15: Installation

    Several options are available to connect the LTC 8555 Series Keyboards to the Allegiant main CPU bay. Although other configurations are possible, the tables below summarize typical connections. Additionally, refer to the system configuration diagrams later in this manual. LTC 8555/00, LTC 8555/01 RS-485 type Keyboards Maximum Distance...
  • Page 16: Ltc 8555/00 And Ltc 8555/01 (Standard Keyboard) Installation

    9600 baud. Requires full duplex RS-232 compatible fiber optic link operating at 9600 baud. LTC 8555/00 and LTC 8555/01 (standard keyboard) Installation There are several options available for connecting these keyboard models to an Allegiant system. The keyboard is supplied with a 3 m (10 ft) cable for local hookups, as shown in FIGURE 1.
  • Page 17: Ltc 8555/02 And Ltc 8555/03 (Rs-232 Protocol Model) Installation

    The table below indicates which keyboard number will be assigned, based on the connection being used. Bosch Security Systems, Inc. Instruction Manual F.01U.127.290 | 2.0 | 2009.03...
  • Page 18: Allegiant System Command Scripts For Rs-232 Model Keyboards

    At the system prompt, manually enter the appropriate command, based on the Allegiant port in use, and type of keyboard interface. Refer to the table below to determine the correct command. Enter the command exactly as shown below, then press ENTER. F.01U.127.290 | 2.0 | 2009.03 Instruction Manual Bosch Security Systems, Inc.
  • Page 19 SET-PORT-RS232 0 4 8 0 1 0 _SET_KBD_MODE 0 1 break Direct to Console port Begin @boot (LTC 8900 only) SET-PORT-RS232 4 4 8 0 1 0 _SET_KBD_MODE 4 1 break Bosch Security Systems, Inc. Instruction Manual F.01U.127.290 | 2.0 | 2009.03...
  • Page 20: Modem Interface Information When Using Rs-232 Model Keyboards

    CONSOLE port on Allegiant User-supplied dial-up Junction box and power system must be configured modem link adapter supplied with LTC 8557 kit RS-232 Keyboard mode Figure 5.6 Connection Using Dial-up Modem Link F.01U.127.290 | 2.0 | 2009.03 Instruction Manual Bosch Security Systems, Inc.
  • Page 21: Console Expander Configuration When Using Rs-232 Model Keyboards

    Figure 5.7 Configuration using LTC 8712 Series Console Port Expander On Allegiant systems with a Printer port, up to two Console Port Expanders can be connected, supporting a total of eight RS-232 model keyboards. Bosch Security Systems, Inc. Instruction Manual F.01U.127.290 | 2.0 | 2009.03...
  • Page 22 Port Expander, as shown in Figure 8. If a modem is being used, follow the same connections and configuration settings described in the previous section when interfacing directly to an Allegiant Console port. F.01U.127.290 | 2.0 | 2009.03 Instruction Manual Bosch Security Systems, Inc.
  • Page 23: Login Feature When Using Rs-232 Model Keyboards

    If the Bosch Security Systems, Inc. Instruction Manual F.01U.127.290 | 2.0 | 2009.03...
  • Page 24: User Information

    If the logon feature is not enabled, it will not be possible to log off the keyboard. If the feature has been enabled and you are currently logged on, press USER, then press OFF. The logged off keyboard displays flashing dashes in the keyboard LED display. F.01U.127.290 | 2.0 | 2009.03 Instruction Manual Bosch Security Systems, Inc.
  • Page 25: Modem Dialing (Applies To Ltc 855/02 And Ltc 8555/03 Models Only)

    (unless they have a higher priority) from controlling the locked pan/tilt/zoom camera. Remember to unlock the camera when finished so that all operators can access it. Bosch Security Systems, Inc. Instruction Manual F.01U.127.290 | 2.0 | 2009.03...
  • Page 26: Lock Or Unlock Control Of A Monitor

    ENTER is held down. Auxiliary outputs 2 through 4 can also be configured as contact closures, 24 VAC, or as line voltage. Auxiliary number 5 controls the DITHER function (see F.01U.127.290 | 2.0 | 2009.03 Instruction Manual Bosch Security Systems, Inc.
  • Page 27: Arm/Disarm Individual Alarms

    If a sequence is already on a monitor, the operator who loaded it originally (or an operator with a higher priority) is permitted to load a new sequence on the monitor or monitors. Others receive an error message. Bosch Security Systems, Inc. Instruction Manual F.01U.127.290 | 2.0 | 2009.03...
  • Page 28: Run A Sequence

    More powerful features are available when sequences are programmed via the PC-based LTC 8059 Master Control Software, including the capability to activate receiver/driver actions as part of a sequence step. F.01U.127.290 | 2.0 | 2009.03 Instruction Manual Bosch Security Systems, Inc.
  • Page 29 To edit an existing sequence, press PROG, enter the existing sequence number, and then press ENTER. You can insert a line into a sequence by navigating to the appropriate line and Bosch Security Systems, Inc. Instruction Manual F.01U.127.290 | 2.0 | 2009.03...
  • Page 30: Programming A Salvoswitching Camera Sequence

    ENTER. When 61 is entered, the switcher automatically changes to the salvo abbreviation SLV. Dwell time (in seconds) is entered only upon reaching the step containing the last monitor to be switched within the synchronized group. F.01U.127.290 | 2.0 | 2009.03 Instruction Manual Bosch Security Systems, Inc.
  • Page 31: Keyboard User Functions

    SELECT CROSSPOINT DATA USE PHYSICAL R/D ADDRESSES SET EXPANDED PRINTER PORT SELECT DIU INTERFACE PORT SET SWITCHER PHASE DELAY (LTC 8100, 8200, & 8300 only) 1 CACHE REMOTE CAMERAS Bosch Security Systems, Inc. Instruction Manual F.01U.127.290 | 2.0 | 2009.03...
  • Page 32: Error Messages

    Refer to the Installation manual supplied with the Allegiant system for a complete listing of error messages applicable to your model system. F.01U.127.290 | 2.0 | 2009.03 Instruction Manual Bosch Security Systems, Inc.
  • Page 33: Data Interface And Cable Pinouts

    Allegiant Side (Console Port) PC Side (Serial Port) Connection Connection No connection 1, 7 CD, RTS No connection Data Gnd Data Gnd No connection No connection (Jumper pins 4 & 6) Bosch Security Systems, Inc. Instruction Manual F.01U.127.290 | 2.0 | 2009.03...
  • Page 34: Troubleshooting

    – Key or LED may be defective. Run the User Function 1 test described in section below. F.01U.127.290 | 2.0 | 2009.03 Instruction Manual Bosch Security Systems, Inc.
  • Page 35: Local Keyboard Test -- Keyboard User Function

    If the login system features have been selected by the system installer, the same local test can be initiated while the keyboard is not online, by pressing “*” (the star key). Bosch Security Systems, Inc. Instruction Manual F.01U.127.290 | 2.0 | 2009.03...
  • Page 36 Digit 8 Camera VALUE Digit 3 Digit 6 Digit 9 Enter Next Prev Hold Clear Focus (high) Focus (low) Iris (high) Iris (low) (Down) (Right) (Up) (Left) User (enter/exit) F.01U.127.290 | 2.0 | 2009.03 Instruction Manual Bosch Security Systems, Inc.
  • Page 37: Icon Translator Chart

    The following chart is used to cross-reference the text descriptions contained in the manual with the icons found on keyboard models LTC 8555/01 and LTC 8555/03. Alarm Camera Clear Enter Focus Hold Iris Lock Monitor Next Prev Prog Shot User Bosch Security Systems, Inc. Instruction Manual F.01U.127.290 | 2.0 | 2009.03...
  • Page 38 | Icon Translator Chart Allegiant Keyboards F.01U.127.290 | 2.0 | 2009.03 Instruction Manual Bosch Security Systems, Inc.
  • Page 40 Phone: +65 6319 3450 Telephone +1 888-289-0096 Fax: +31 40 2577 330 Fax: +65 6319 3499 +1 585-223-9180 [email protected] [email protected] Email: [email protected] www.boschsecurity.com www.boschsecurity.com www.boschsecurity.us © Bosch Security Systems, Inc. 2009; F.01U.127.290 | 2.0 | 2009.03; Data subject to change without notice.

Table of Contents