Bosch CCS 800 Ultro Installation And Operating Manual

Discussion system
Hide thumbs Also See for CCS 800 Ultro:
CCS 800 Ultro
zh-t
zh-s
th
ja
Installation and Operating Manual
en
Discussion System
Manuel d'installation et d'utilisation
fr
Système de Discussion
Installations- und Bedienungshandbuch
Diskussionssystem
de
Manual de instalación y funcionamiento
es
Sistema de Conferencias
Installatie- en gebruikshandleiding
nl
Discussiesysteem
Installazione e Manuale operativo
it
Sistema audio congressuale
Table of Contents
loading

Summary of Contents for Bosch CCS 800 Ultro

  • Page 1 CCS 800 Ultro Installation and Operating Manual Discussion System Manuel d’installation et d’utilisation Système de Discussion Installations- und Bedienungshandbuch Diskussionssystem zh-t Manual de instalación y funcionamiento zh-s Sistema de Conferencias Installatie- en gebruikshandleiding Discussiesysteem Installazione e Manuale operativo Sistema audio congressuale...
  • Page 2 Page Prior to installing or operating this product always read ..................... the Safety Instructions which are available as a separate document. Avant d 'installer ou d'utiliser ce produit, lisez toujours .................... les Instructions de sécurité disponibles dans un docu- ment distinct. Lesen Sie vor Installation oder Inbetriebnahme dieses ..................
  • Page 3: About This Manual

    About this manual Introduction This "Instructions For Use" manual provides all the The CCS 800 Ultro Discussion System is a discussion information required to install and operate the CCS 800 system for use in meeting and conference venues with a Ultro Discussion System.
  • Page 4 CCS 800 Ultro | Installation and Operating Manual en | 6 Control and power supply 4 Speaker volume control of all connected delegate and chairman units. unit (CPSU) 5 Volume control of the speaker or headphone of the CPSU. 6 Headphone connection with 3.5 mm stereo jackplug socket.
  • Page 5: Delegate And Chairman Unit

    CCS 800 Ultro | Installation and Operating Manual en | 7 14 Mains input connection. Use the included mains 9 Chairman Priority button. When pressed emits cord to connect the CPSU to the mains socket. chime tone, overrules/mutes all active microphones...
  • Page 6: Connecting Up To 150 Units

    CCS 800 Ultro | Installation and Operating Manual en | 8 5.2 Connecting up to 150 units CCS 800 Ultro can be used with up to 150 units by adding maximum 2 additional control units acting as power supply units only. The system is controlled by the master LBB 3310.
  • Page 7 CCS 800 Ultro | Installation and Operating Manual en | 9 5.5 Connecting a wireless Connect the cabling of the tape recorder (2) to the microphone recorder input and output of the CPSU (1). Use the gain control (3) to adjust the sensitivity of the recorder input of the CPSU.
  • Page 8: Connecting A Telephone Coupler

    5. 1 0 Mains connection isolation between the telephone network (PBX) and the CCS 800 Ultro system. The telephone coupler shall also meet all relevant requirements for this type of Trunk in/out...
  • Page 9 CCS 800 Ultro | Installation and Operating Manual en | 11 Operation 6. 1 Testing the connection of the delegate and chairman units CCS 800 ULTRO Figure 6. 1 Put the mode selector in the test position, all light-ring indicators and LEDs of the delegate and chairman units must lit if properly connected.
  • Page 10: Using The Priority Button

    CCS 800 Ultro | Installation and Operating Manual en | 12 6.3 Using the microphone button of the chairman unit 1...4 1...4 Figure 6.3 Pressing the microphone button on a chairman unit 6.5 Priority mode settings in always activates the chairman microphone, independent chairman unit of the selected microphone mode.
  • Page 11: Open Mode

    CCS 800 Ultro | Installation and Operating Manual en | 13 6.6 Open mode Select the max. number ( 1, 2, 3 or 4) of delegate microphones which can be active at the same time. Note Chairmen can always switch on and off their microphones and are not included in the max.
  • Page 12: Override Mode

    CCS 800 Ultro | Installation and Operating Manual en | 14 6.8 Override mode CCS 800 ULTRO Figure 6.8 Each time a delegate presses the microphone button on a delegate unit, it will override the currently active delegate unit. So only one delegate microphone is active at the same time.
  • Page 13 CCS 800 Ultro | Installation and Operating Manual en | 15 6. 1 0 Volume control of the delegate and chairman units CCS 800 ULTRO Figure 6. 1 0 Turn the volume control (1) to set the volume of the loudspeakers of the delegate and chairman units (2).
  • Page 14: Monitoring Volume Control

    CCS 800 Ultro | Installation and Operating Manual en | 16 6. 1 2 Monitoring volume control CCS 800 ULTRO Figure 6. 1 2 6. 1 3 Using a headphone Use the built-in loudspeaker or a headphone to monitor the discussion. Adjust the volume using the monitoring volume control.
  • Page 15: Troubleshooting

    CCS 800 Ultro | Installation and Operating Manual en | 17 Troubleshooting Part of system not working Possible cause • Temporary no microphone reaction, and no sound or Interrupted trunk-line cabling. distorted sound from unit loudspeakers Solution • Possible cause •...
  • Page 16: Technical Data

    CCS 800 Ultro | Installation and Operating Manual en | 18 Technical data Monitor loudspeaker Output level at 0.5 m: 72 dB SPL/ 82 dB SPL (nominal/maximum) 8. 1 System Electrical and Electro- Frequency response: 320 Hz ... 10 kHz Acoustical Characteristics (-10 dB, ref.
  • Page 17: General Data

    CCS 800 Ultro | Installation and Operating Manual en | 19 8.3 General Data 8.1.2 Combined Units Delegate microphones with transmission links to 8.3.1 System Environmental Conditions delegate headphones and auxiliary outputs. Temperature range General Storage and transport: -20 to +70°C (-4 to +158°F) Frequency response: 125 Hz - 12.5 kHz tolerances...
  • Page 18 CCS 800 Ultro | Installation and Operating Manual en | 20 8.3.2Equipment Range Control and power supply unit: LBB 3310/00 LBB 3310/10 (with Digital Acoustic Feedback Suppression) 19" rack mounting set: LBB 3311/00 Bracket for flush mounting: can be made locally according to...
  • Page 19: Pin Configuration

    CCS 800 Ultro | Installation and Operating Manual en | 21 Appendix 9. 1 Pin Configuration CCS 800 ULTRO Trunk in/out Microphone Recorder Line Telephone Insertion Digital Acoustic Gain Gain Feedback Suppression 90-260 V~ Figure 9. 1 9.1.1 Trunk Connections (A) 9.1.2 External Microphone (XLR) (B)
  • Page 20: Mounting Instructions

    CCS 800 Ultro | Installation and Operating Manual en | 22 9.2 Mounting Instructions 9.1.5 Headphone Jack-plug (3.5mm) (E) 1 Tip - Signal + 2 Ring - Signal - The CPSU can be attached in three different ways: 3 Sleeve - Electrical earth/screen •...