Bosch DVR 630/650 Installation And Operation Manual

Bosch DVR 630/650 Installation And Operation Manual

Video recorder
Table of Contents
Video Recorder 630/650 Series
DVR 630/650 Series
en
Installation and Operation manual
Table of Contents
loading

Summary of Contents for Bosch DVR 630/650

  • Page 1 Video Recorder 630/650 Series DVR 630/650 Series Installation and Operation manual...
  • Page 3: Table Of Contents

    Hardware setup Camera connections Audio connections Monitor connections 4.3.1 VGA (Monitor A and Monitor B) Keyboard connections Ethernet connection RS485 port USB connectors External alarm I/O connection Power supply Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
  • Page 4 Continuous Recording 6.1.5 Input Recording 6.1.6 Motion Recording 6.1.7 Network Live Streaming 6.1.8 Video format Schedule 6.2.1 Schedule Display 6.3.1 Language 6.3.2 Monitor A 6.3.3 Monitor B Event F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
  • Page 5 8.2.1 Open button Camera Views Viewing Images 8.4.1 Assigning Cameos Using the playback controls 8.5.1 Capturing a still image Find image Video slider bar Checking authenticity Exit button Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
  • Page 6 Electromagnetic and Safety 10.2 DVD compatibility 10.3 USB memory sticks Appendix Software licenses A.1.1 Bosch software A.1.2 Other licenses — copyright notices A.1.3 Warranties and disclaimer of warranties F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
  • Page 7: Safety

    Controls adjustment - Adjust only those controls specified in the operating instructions. Improper adjustment of other controls may cause damage to the unit. Use of controls or Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
  • Page 8 17. Attachments, changes or modifications - Only use attachments/accessories specified by the manufacturer. Any change or modification of the equipment, not expressly approved by Bosch, could void the warranty or, in the case of an authorization agreement, authority to operate the equipment.
  • Page 9: Important Notices

    Disposal - Your Bosch product was developed and manufactured with high-quality material and components that can be recycled and reused. This symbol means that electronic and electrical appliances, which have reached the end of their working life, must be collected and disposed of separately from household waste material.
  • Page 10 SELV - All the input/output ports are Safety Extra Low Voltage (SELV) circuits. SELV circuits should only be connected to other SELV circuits. Video loss - Video loss is inherent to digital video recording; therefore, Bosch Security Systems cannot be held liable for any damage that results from missing video information. To minimize the risk of lost digital information, Bosch Security Systems recommends multiple, redundant recording systems, and a procedure to back up all analog and digital information.
  • Page 11: Fcc And Ul

    UL MAKES NO REPRESENTATIONS, WARRANTIES, OR CERTIFICATIONS WHATSOEVER REGARDING THE PERFORMANCE OR RELIABILITY OF ANY SECURITY OR SIGNALING- RELATED FUNCTIONS OF THIS PRODUCT. Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
  • Page 12: Bosch Notices

    | Safety Video Recorder 630/650 Series Bosch notices Copyright This manual is the intellectual property of Bosch Security Systems and is protected by copyright. All rights reserved. Trademarks All hardware and software product names used in this document are likely to be registered trademarks and must be treated accordingly.
  • Page 13: Introduction

    2.1.1 Versions There are various DVR 630/650 Series models; the most extensive model has 16 channels and a built-in DVD writer. The DVR 630 does not have a DVD writer; the DVR 650 does. 2.1.2...
  • Page 14: Features

    If any items are missing, notify your customer service representative or Bosch Security Systems sales representative. The shipping carton is the safest container in which to transport the unit. Save it and all packing materials for future use.
  • Page 15: Installation Environment

    Warranty Failure to follow the Safety Instructions, Installation Instructions, and any other instructions noted in this manual may result in damage to the unit and void the warranty. Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
  • Page 16: Quick Install

    Connect a pan/tilt/zoom control unit to the RS-485 port (via the supplied screw terminal block). Connect to your network via the Ethernet port. Connect a Bosch Intuikey keyboard cable to the Keyboard-IN port if required. 3.1.3 Powering up Switch on all connected equipment.
  • Page 17: First-Time Use

    To restore the unit to its factory default: Remove power from the DVR. Press and hold the OSD key on the front panel. Supply power to the unit. – The factory defaults are restored. Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
  • Page 18: Quick Install Menu

    Fill in the current time. Date format Select from three date formats which show either the month (MM), the day (DD), or the year (YYYY) first. Date Fill in the current date. F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
  • Page 19: Continuous Recording

    Quick install | en 3.3.2 Continuous Recording Figure 3.4 Quick install - Continuous Recording Set the Continuous Recording Resolution, Quality, Frame rate, Covert, and Audio for each profile in the table. Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
  • Page 20: Network

    The actual values are displayed. IP address, Subnet Fill in the IP, subnet mask, gateway addresses, and DNS server mask, and Gateway addresses when DHCP is not enabled. F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
  • Page 21: Hardware Setup

    Gain control: Automatic gain control for each video input Connector type: BNC looped-through, automatic termination Figure 4.1 16 video inputs with loop-through outputs Figure 4.2 8 video inputs with loop-through outputs Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
  • Page 22: Audio Connections

    Resolution: 800x600 (4:3), 1024x768 (4:3), or 1280x1024 (5:4), 1366x768 (16:9) and 1440x900 (16:10) for Monitor A; 800x600 (4:3) for Monitor B Color: True color (32 bit) Connector type: DE-15 Figure 4.4 VGA monitor connectors F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
  • Page 23: Keyboard Connections

    Hardware setup | en Keyboard connections The keyboard input and output connectors are used to connect a Bosch Intuikey keyboard to one or more DVR 600 Series units. For one unit, connect the keyboard to the Keyboard in connector. For more units, connect a cable between the Keyboard out connector of the first unit and the Keyboard in connector of the following DVR 600 Series unit.
  • Page 24: Ethernet Connection

    Supports 3.3V or 2.5V signaling for RGMII – Supports power down mode and supports Link Down Power Saving – 64-pin QFN or 100-pin LQFP – Connector: RJ45 Figure 4.6 RJ-45 Ethernet connector F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
  • Page 25: Rs485 Port

    Video Recorder 630/650 Series Hardware setup | en RS485 port Connect Bosch, Pelco-P or Pelco-D controllable cameras to the unit for pan, tilt, and zoom control. The Bosch protocol is supported with the following baud settings: – 9600 baud –...
  • Page 26: Usb Connectors

    USB memory device. (Recording to a USB-drive is not supported.) Figure 4.8 USB connector (on front and on rear) Note: USB memory sticks must have FAT32 formatting. F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
  • Page 27: External Alarm I/O Connection

    Cable cross section: AWG 26-16 (0.13-1.5 mm2) Figure 4.9 Alarm input connector for 16-channel model Figure 4.10 Alarm input connector for 8-channel model Figure 4.11 Alarm output connector Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
  • Page 28: Power Supply

    Electrical voltage. Risk of electric shock. Do not open the top cover or attempt to service the unit. No user serviceable parts inside. Refer all servicing to qualified service personnel. F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
  • Page 29: Operating Instructions

    System Menus Covert Table 5.1 User Levels and permissions Front panel controls Figure 5.1 Front panel controls Note: 8-channel models have only 8 camera keys on the front. Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
  • Page 30: Keys

    – in quad mode, press to toggle to full screen Sequence key – view cameras in sequence on full-screen or quad displays F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
  • Page 31: Indicators

    Power - lights green when the unit is powered Network - lights green to indicate network activity Alarm - flashes red when an alarm is detected Record - lights red when the unit is recording video Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
  • Page 32: Mouse Controls

    The buttons and indicators of the System Control Bar work the same as the keys and indicators on the front panel. – The System Control Bar can also be controlled with the Arrow Keys and Enter Key. F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
  • Page 33: Remote Control

    Press the ID button on the remote control. Press a number between 1 and 9 that corresponds to the unit ID you wish to control. Figure 5.3 Remote control Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
  • Page 34: Viewing Pictures

    From the pop-up menu, select the display for Monitor B – Select the quad key to select the quad mode – Select the sequence key to sequence the quad mode F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
  • Page 35: Viewing

    Table 5.2 Multi-screen viewing in 4:3 and 5:4 Resolution (aspect ratio) 1366x768 (16:9), 1440x900 (16:10) Full screen Quad 1+2+6 4x4 (Not for 8-channel model) Table 5.3 Multi-screen viewing in 16:9 and 16:10 Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
  • Page 36 Alternatively, right click a cameo with the mouse and choose a video input from the Cameo Menu. This cameo assignment is used in playback mode as well as in live mode. F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
  • Page 37 Alternatively, right click and select Zoom or Exit zoom to enable or disable zoom mode with the mouse. While in zoom mode, move the mouse pointer to select the area of the picture to be displayed. Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
  • Page 38: Live And Playback

    – Press the play key to resume playback. Press the stop key to switch back to live viewing. An alarm also switches the unit back to live viewing. F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
  • Page 39: Overview Of The Menu System

    To open the menu, move the pointer to the bottom of the screen. – The System Control Bar appears on monitor A. To open the menu, click the menu icon. Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
  • Page 40: Main Menu

    NTP - set NTP Time Server and Sync interval – Beeper - set unit to beep on Button, Input, Motion, System, or Video loss – User - set Usernames, Passwords, and User Levels for Users 1-10 F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
  • Page 41: Search

    Move the cursor to the bottom of the screen to access the System Control Bar. Click the search icon. – The default search is a Date/time search. Figure 5.5 Default menu - Search Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
  • Page 42: Date/Time Search

    With a mouse, click directly on the timeline to set the start time. Click Play to start playback: – Playback in all displayed cameos will start. Figure 5.6 Search menu - Date/Time Search options F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
  • Page 43: Event Search

    The event search results are indicated by a start and stop time of a small period of video. Within this period of video the event search results can be found. Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
  • Page 44: Smart Search

    The smart search results are indicated by a start and stop time of a small period of video. Within this period of video the smart search results can be found. F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
  • Page 45: Export

    If the total size of the video segments is greater than the memory device’s free space, then only the first segments that fit are archived. Click File to save ‘Export history log file’ to USB. Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
  • Page 46: System Information

    – MAC Address – IP Address – Software Version Figure 5.10 System Control Bar - System information Click Video info to see more information about the video connections. F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
  • Page 47 The video information menu shows the video system that has been set and the inputs on which video signals have been detected. Click Hard disk to see more information about the hard disks. Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
  • Page 48 The Disk info menu provides information on the size and usage data of the hard drives. Note: Only Bosch hard disks with a signature can be used. If the hard disk is not certified, it cannot be used for recording.
  • Page 49: Log

    – Log contents are ordered from latest to earliest. Export log click Export to save the log file to a USB device. Figure 5.13 Logbook - Logbook filter Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
  • Page 50: Triggers And Alarms

    Monitor B: Full screen or sequenced display of pre-programmed cameras. – The alarm beeper sounds. The alarm indicators flash. – A controllable camera might be moved to a pre-defined position. F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
  • Page 51: Motion Events

    Monitor A can switch to a multiscreen view if more than one alarm occurs. The latest alarm status message is always shown. Press the acknowledge key to deactivate all alarms. Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
  • Page 52: Configuration Menu

    The configuration menu has six major menu groups listed across the top. Each of these groups has a set of drop-down submenus which provide access to a screen where the values and functions can be selected and changed. F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
  • Page 53 Monitor A Monitor B Event Input Motion Alarm Acknowledge System Network TCP/IP DDNS Notification Mail System Date/Time Beeper User Configuration Hard Disk System Table 6.1 System Configuration menu structure Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
  • Page 54: Camera

    Administrator level users are able to view live, playback, and archive covert video. Audio Enable Audio input when an audio source is connected for the specified channel. F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
  • Page 55: Video Adjustment

    Table 6.2 Maximum Frame Rates (PAL/NTSC IPS) by Resolutions for enabled Channels 6.1.2 Video adjustment Figure 6.3 Camera - Video adjustment Channel Select the camera channel for adjustment. The preview will display the channel indicated. Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
  • Page 56: Ptz

    Select a COM port, Control ID, and Protocol for PTZ when a controllable camera is connected. – Pan and Tilt can be tested within the menu. – By default, PTZ is disabled (Com port is set to None) for all inputs. F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
  • Page 57: Continuous Recording

    Frame rate - set the video frame rate to 25/30, 12.5/15, 6.25/7.5, 5/6, 2.5/3, or 1/1 IPS (Images Per Second in PAL/NTSC). Note: For 16-channel units, use the ch09 to ch16 or ch01 to ch08 button to display the required cameras. Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
  • Page 58: Input Recording

    The pre-event recording time is dependent on video complexity, resolution, quality, and frame rate settings. Post-event Post-event recording duration can be set between 10 seconds and 10 minutes, or set to Follow the alarm state. F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
  • Page 59: Motion Recording

    Figure 6.8 Camera - Network Live Streaming Use the same procedure as Continuous Recording to set the values for cameras that will be streamed over the network. – Network streams are not recorded. Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
  • Page 60: Video Format

    DVR to either PAL or NTSC. Select the Monitor format to match the best VGA resolution on the used VGA monitor (monitor A). F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
  • Page 61: Schedule

    Use Day copy to copy the settings of the schedule to another day. – Use Ch copy to copy the settings of the schedule to another channel. When finished, select Exit to save the updated schedule. Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
  • Page 62: Display

    The Sequence dwell time is used during Sequence or if multiple active events trigger the monitor. 6.3.3 Monitor B Use the same procedure as Monitor A (playback items are not available). F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
  • Page 63: Event

    For the camera associated with the input, a PTZ preset can be sent to the camera to move to a specified pre-position. – Enter a pre-position number from 1-255 for each of the PTZ cameras that should be moved. Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
  • Page 64: Motion

    Use the arrow keys to move around the grid, pressing the enter key to toggle each grid block from active to inactive. – Click Set All to set the selected area to its default value. Click Clear All to delete the selected area. F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
  • Page 65: Alarm Acknowledge

    Select the Post-event time to enable the unit to automatically acknowledge alarms when the post-event time is expired. Select Manual to require the operator to press the Acknowledge key to acknowledge an alarm. Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
  • Page 66: System Menu

    Figure 6.15 Event - System menu For each system event, select relay number 1, 2, 3 or 4 to activate an output relay when an events occurs, or select None for no activation. F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
  • Page 67: Network

    Connecting using a smart mobile phone Your smart phone should support RTSP network protocol and includes a RTSP capable player application that can display H.264 video streams. The RTSP transports the remote (network) Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
  • Page 68 If the RTSP port is not the default port (554), use the following on the smart phone. – rtsp://xxx.xxx.xxx.xxx:firewall open port/cgi-bin/rtspStream/1 Note: xxx.xxx.xxx.xxx is the DVR IP address; 1 refers to channel 1, 2 refers to channel 2, etc. F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
  • Page 69: Ddns

    The providers supported are: dyndns.org, tzo.com, and sitessolutions.com. 6.5.5 Notification Figure 6.18 Network - Notification Select the events that will trigger the unit to send an e-mail. Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
  • Page 70: Mail

    If not required, do not enable this feature. User name and Password If authentication is required, regardless of encryption, enter the User name and Password provided by your administrator in each field respectively. F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
  • Page 71: System

    Press NTP Test to start time synchronization. Set the Synchronization Interval to keep the unit closly matched with the time source. – Intervals can be as frequent as hourly, or as long as monthly. Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
  • Page 72: Beeper

    Enter a Password up to 12 characters. Control access to the system by selecting a user Level. – User Level can be set to Administrator, Advanced or Normal user. F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
  • Page 73: Configuration

    Once started, the unit must not be powered off until the update is completed. – Quick install opens the Quick install menu that was first presented when the unit was powered on when received from the factory. Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
  • Page 74: Hard Disk

    Auto delete sets a time window outside of which all video will be deleted from the unit. This function is primarily reserved to meet legal requirement in some jurisdictions. – Format erases all data from the selected partition. F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
  • Page 75: System

    – Auto user logout sets the period of inactivity after which the user will be automatically logged out from the unit. Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
  • Page 76: Web Client Software

    – Once installed on a PC, the Web Client will not need to install the OCX again unless a new version is released with a new unit firmware. F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
  • Page 77: How To Log On

    The Web Client allows access to and use of unit menu items. These menu items are explained in Section 6 Configuration menu, page 52. Although the structure is the same, menus and settings behave differently because of the Web Browser. Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
  • Page 78: Introducing The Browser Window

    On this screen, the user can: – view live video – select different multiscreen displays – assign cameras to cameos – control ptz cameras – monitor unit status and alarm conditions F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
  • Page 79: Camera Views

    – view a graphical timeline of the day for recording, input, or motion events. Figure 7.3 Web Client - Playback Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
  • Page 80: Export Mode

    On this screen, the user can: – export a file remotely to the PC; – choose the channel, audio, start and end date/times to export. Figure 7.4 Web Client - Export F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
  • Page 81: Configuration Mode

    Configuration mode Click the Configuration button to enter the Configuration menu. This allows set up of all the configuration settings for the unit. Figure 7.5 Web Client - Configuration Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
  • Page 82: Archive Player

    – If the file is not listed, scroll down the list or choose the right location. Click Open. To exit the program, click Cancel or the close button. F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
  • Page 83: Introducing The Main Window

    When zoom is selected, left click on the cameo to zoom out, right click to zoom in. Click, hold, and drag inside the cameo to move the image around. Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
  • Page 84: Viewing Images

    The step function is only enabled in the still mode. Click Step backward to move the image back one frame. Hold it down to continue stepping at a maximum rate of 3 images per second. F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
  • Page 85: Capturing A Still Image

    This opens the Authenticity information window. This window shows details of the video frame shown in the cameo when it was clicked. Exit button Click the Exit button to stop using the Archive Player. Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
  • Page 86: Menu Default Values

    Cameras 1-8/16 Resolution Recording Video quality Normal Frame rate 30 (NTSC)/25 (PAL) Covert Audio None Network Setup DVR ID DHCP Enabled IP address 0.0.0.0 Subnet mask 0.0.0.0 Gateway 0.0.0.0 F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
  • Page 87 Video format Auto-Detect on Camera 1 Monitor format 800x600 (4:3) Schedule Sunday Continous Monday Continous Tuesday Continous Wednesday Continous Thursday Continous Friday Continous Saturday Continous Exception Days None Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
  • Page 88 All On Alarm acknowledge Post-Event Time System Disk Fail None Disk Full None Fan Fail None System/Disk Temp None Admin Password None Changed Video Loss None Power On None F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
  • Page 89 Send Mail SMTP Server EMPTY SMTP Port User Name EMPTY Password EMPTY More Mail Settings From EMPTY Subject EMPTY To (1) EMPTY To (2) EMPTY To (3) EMPTY Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
  • Page 90 Start Start of Video Current Time Sensitivity Area Table 9.4 Archive menu default values Navigation Setting Default value Reset Archive Channel None Start Time None End Time None F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
  • Page 91: Technical Specifications

    Control RS485 Output signals according to RS485 max. signal voltage -8 V to +12 V RS485 support Bosch domes and Pelco-P and D Keyboard Intuikey; 12 VDC, 400 mA max. Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
  • Page 92: Mechanical

    355 x 362 x 78 mm (W x D x H) 13.9 x 14.2 x 3.1 inch (W x D x H) Weight (excluding hard disk) approx. 4.3 kg / 9.46 lbs F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
  • Page 93: Environmental

    Operating: 0 °C to +40 °C (+32 °F to +104 °F) Storage: -40 °C to +70 °C (-40° F to +158 °F) Relative humidity Operating: <93% non-condensing Storage: <95% non-condensing Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
  • Page 94: Electromagnetic And Safety

    EMC directive 2004/108/EC Immunity EN50130-4 Emission EN55022 Class B Harmonics EN61000-3-2 Voltage fluctuations EN61000-3-3 Safety UL60950-1 LV Directive 2006/95/EC, EN60950-1 Canada CAN/CSA - C22.2 no. 60950-1 Australia C-Tick F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
  • Page 95: Dvd Compatibility

    Kingston DataTraveler II plus MIGO 8 GB Table 10.2 Recommended USB memory sticks Note: USB memory sticks must be formatted according to the FAT32 standard. No other standard is allowed. Bosch Security Systems Installation and Operation manual F.01U.169.663 | v2.0 | 2012.02...
  • Page 96: A Appendix

    – CDDL v1.0 — http://www.openssl.org/source/license.html Bosch is committed to comply with the relevant terms of any open source license included in its products. To this effect, Bosch has created a web site (www.boschsecurity.com/oss) to enable any licensee of open source software to have access to the relevant source code or other information that such licensee may be entitled to under the terms of a relevant license.
  • Page 97: Warranties And Disclaimer Of Warranties

    Bosch is entitled to charge fees for any services in relation thereto.
  • Page 98 | Video Recorder 630/650 Series F.01U.169.663 | v2.0 | 2012.02 Installation and Operation manual Bosch Security Systems...
  • Page 100 Bosch Security Systems www.BoschSecurity.com © Bosch Security Systems, 2012...

This manual is also suitable for:

630 series650 series

Table of Contents