GE 10 AZA Owner's Manual

Ge room air conditioner owner's manual and installation instructions

Quick Links

www.GEAppliances.com
Safety Information
Connecting Electricity . . . . . . . . . . 3
Safety Precautions . . . . . . . . . . . . . . 2
Operating Instructions
Air Direction . . . . . . . . . . . . . . . . . . . 6
Controls . . . . . . . . . . . . . . . . . . . . . 5, 6
Fan Switch . . . . . . . . . . . . . . . . . . . . . 6
Temperature Limiting . . . . . . . . . .6
Vent Control . . . . . . . . . . . . . . . . . . .6
Air Filter . . . . . . . . . . . . . . . . . . . . . . . 8
Front Grille . . . . . . . . . . . . . . . . . . . . .7
Grille and Case . . . . . . . . . . . . . . . . . 7
Outdoor Coils . . . . . . . . . . . . . . . . . . 7
Installation
Installation for Models with
Accordion Curtains . . . . . . . . .17-21
Installation for Models with
Filler Panels . . . . . . . . . . . . . . . .10-16
Preparing to Install . . . . . . . . . . . . . 9
Consumer Support
Consumer Support . . . . Back Cover
Warranty . . . . . . . . . . . . . . . . . . . . . 27
Write the model and serial numbers here:
# ________________________________
# ________________________________
Find these numbers on a label on the
front of the base pan behind the front grille.
Owner's Manual and
Installation Instructions
Standard and Easy Mount
Cool Only:
AJCS 06
AJCS 08, 10
Heat/Cool: AJES 06
AJES 08
AJES 10
Heat Pump: AJHS 08
49-7398 10-00 JR
LZA
AZA
LSA
ASA
DSA
ASA
Table of Contents
loading

Summary of Contents for GE 10 AZA

  • Page 1: Table Of Contents

    www.GEAppliances.com Safety Information Adapter Plugs ....4 Connecting Electricity ..3 Extension Cords ....4 Safety Precautions .
  • Page 2: Important Safety Information

    SAFETY PRECAUTIONS Use this appliance only for its intended purpose as described in this Owner’s Manual. This air conditioner must be properly installed in accordance with the Installation Instructions before it is used. Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the receptacle.
  • Page 3: Connecting Electricity

    3-prong wall outlet. www.GEAppliances.com The air conditioner should always be plugged into its own individual electrical outlet which has a voltage rating that matches the rating plate.
  • Page 4: Use Of Adapter Plugs

    If the adapter ground terminal breaks, DO NOT USE the air conditioner until a proper ground has been established. Attaching the adapter ground terminal to a wall outlet cover screw does not ground the appliance...
  • Page 5: Controls

    Heat Pump Models When the outdoor temperature is lower than 25°F., heat is provided by the electric heater in the air conditioner instead of by the heat pump. NOTE: The electric resistance heater in the 115-volt heat pump model operates during defrost when the outdoor coil temperature is below 36°F.
  • Page 6: Air Direction

    About the controls on the air conditioner. Fan Switch On Heat/Cool models, the fan switch lever is located in a hole through the control panel. To reach it, you need to remove the front grille. Use a small screwdriver to change the setting. Cool only models have a rocker switch on the front of the control box.
  • Page 7: Care And Cleaning Of The Air Conditioner

    If they are clogged with dirt or soot they may be professionally steam cleaned, a service available through your GE service outlet. Front Grille The front grille can be removed for more thorough cleaning or to make the model and serial numbers accessible.
  • Page 8: Air Filter

    Replacement filters are available from your salesperson, GE dealer, GE Service and Parts Center or authorized Customer Care® servicers.
  • Page 9: Preparing To Install

    NOTE TO CONSUMER: Keep this Owner’s Manual and Installation Instructions for future use. IMPORTANT NOTES: For personal safety, this air conditioner must be properly grounded. It is important to have the wall outlet and circuit checked by a qualified electrician if there is any doubt as to whether a proper ground exists.
  • Page 10: Filler Panels

    (for installation of model AJCS—with accordion curtains, see pages 17–21) Read these instructions completely and carefully. IMPORTANT: Be sure to remove the shipping pad inside the air conditioner next to the compressor. Parts included for models AJES and AJHS. Sill support...
  • Page 11 These instructions are for a standard double- hung window. You will need to modify them for other types of windows. The air conditioner can be installed without the accordion panels if needed to fit in a narrow window. See the window opening dimensions to the right.
  • Page 12 Locking plate Remove screw Remove and discard the shipping screw on the back of the air conditioner to allow removal of the air conditioner from the case. Remove screw Pull the bottom corners of the air conditioner and slide it out of the case.
  • Page 13 Prepare the Window Mark the centerline of the stool. Measure from the centerline 13 for the panel cuts. Stool Sill Install the Sill Supports Assemble the sill supports. Do not fully tighten the spacer mounting screws at this time. Type B Type E Sill support...
  • Page 14 (see Prepare the Window) to the inside of the window track on each side. (A and B) Sill ⁄ Width of the air conditioner Left side Mark the A and B measurements on each side of the filler panel board. Cut the panels and discard the center piece.
  • Page 15 Install the Case in the Window Peel off the backing from the bottom window gasket. Place the gasket on the stool and over the brackets, even with the rear edge, sticky side down. Bottom window gasket Carefully slide the empty case into the window until the holes in the case line up with the holes in the panel angles.
  • Page 16 Stuff the foam between the glass and the window to prevent air and insects from getting into the room. Replace the Air Conditioner in the Case Carefully slide the air conditioner back into the case. Attach the power cord to the base pan with the clamp.
  • Page 17: Accordion Curtains

    Read these instructions completely and carefully. Parts included for model AJCS. Accordion curtain (left) Sill channel Type A (6) Foam top window gasket Foam top window gasket Top mounting rail Window locking bracket Accordion curtain (right) Air conditioner Type B (15)
  • Page 18 These instructions are for a standard double- hung window. You will need to modify them for other types of windows. The air conditioner can be installed without the accordion panels if needed to fit in a narrow window. See the window opening dimensions to the right.
  • Page 19 Locking plate Remove screw Remove and discard the shipping screw on the back of the air conditioner to allow removal of the air conditioner from the case. Remove screw Pull the bottom corners of the air conditioner and slide it out of the case.
  • Page 20 Installation for model AJCS—with accordion curtains. Read these instructions completely and carefully. Prepare the Case Install the top mounting rail with type B screws. Attach the sill channel with type B screws. Align the holes on the bracket of the sill channel with the holes in the case.
  • Page 21 Stuff the foam between the glass and the window to prevent air and insects from getting into the room. Replace the Air Conditioner in the Case Carefully slide the air conditioner back into the case. Attach the power cord to the base pan with the clamp.
  • Page 22: Through-The-Wall Installation

    For the 230/208-volt models the cord length is 65 to the right and 39 to the left. Support Requirements for the Air Conditioner The air conditioner wall case may be installed flush with the inside wall or flush with the outside wall.
  • Page 23 Notes. www.GEAppliances.com...
  • Page 24 Notes.
  • Page 25 Notes. www.GEAppliances.com...
  • Page 26: Troubleshooting Tips

    • Clean the filter at least every 30 days. See the Care and cleaning of the air conditioner section. • When the air conditioner is first turned on you need to allow time for the room to cool down or warm up.
  • Page 27: Air Conditioner Warranty

    Any part of the air conditioner which fails due to a defect in materials or workmanship. One Year During this full one-year warranty, GE will also provide, free of charge, all labor From the date of the and in-home service to replace the defective part.
  • Page 28: Consumer Support

    Caution must be exercised, since improper servicing may cause unsafe operation. Contact Us If you are not satisfied with the service you receive from GE, contact us on our Website with all the details including your phone number, or write to: General Manager, Customer Relations Register Your Appliance Register your new appliance on-line—at your convenience! Timely product registration will allow for...

Table of Contents