Emerson 20C13T-41002 Installation, Operation & Service Manual
Emerson 20C13T-41002 Installation, Operation & Service Manual

Emerson 20C13T-41002 Installation, Operation & Service Manual

Thru-the-wall electronic air cleaner
I:_MI:_RSON
THRU
THE-WALL
ELECTRONIC
AIR
CLEANER
INSTALLATION
OPERATION
SERVICE
Model
Nos.
1 0C1 3T-41 002
14C1 3T-41 002
20C1 3T-41 002
MANUAL
NO. 846-0262
Table of Contents
loading

Summary of Contents for Emerson 20C13T-41002

  • Page 1 I:_MI:_RSON THRU THE-WALL ELECTRONIC CLEANER Model Nos. INSTALLATION 1 0C1 3T-41 002 14C1 3T-41 002 OPERATION 20C1 3T-41 002 SERVICE MANUAL NO. 846-0262...
  • Page 2: Table Of Contents

    INTRODUCTION Thru-the-Wall electronic air cleaners are designed to provide maximum air cleaning in applications where a single central return air duct is employed, or where the central heating or conditioning is in a limited access area. Thru-the-Wall units may be installed in the wall such as in closet installations ceiling...
  • Page 3: How Your Air Cleaner Works

    HOW YOUR AIR CLEANER WORKS (See figure 1.) Dirt laden air enters the unit from the room. It passes through the screen (A) first where large particles (hair, lint, etc.) are trapped. Smaller particles (smoke, dust, pollen, etc.) pass through this screen and enter the Ionizing Section (B).
  • Page 4: Preinstallation

    PREINSTALLATION SUPPLY-AIR STUD PLENUM WALL SURFACE-*- WALL SURFACE -- "1 L,.- 6IN.-- SUPPLY-AIR RETURN-AIR DUCT DUCT _,. RETU RN-AIR DUCT FURNACE AIR CLEANER STUD CLEANE I ,,.,-d TYPICAL WA LL LOCATI TYPICAL INSTALLATION USING DUCT EXTENSION Figure 4 Figure 5 TAPEJOINT LOCATING THE AIR CLEANER...
  • Page 5 3//4 ,, GRILLE " DIM. 1000 CFM 1400 CFM 2000 CFM 28-7/8 16-15/16 23-7/8 9-7/16 21-7/16 16-7/16 30-3/8 18-7/16 25-3/8 Refer to page 2 for model numbers and CFM cross references. FRAME ASSEMBLY REAR VIEW GRILLE CABINET Figure 8 WALL (OR CEILING) CABINET MECHAN ICAL INSTALLATION...
  • Page 6: Installation

    INSTALLATION CAUTION: READ INSTRUCTIONS COMPLETELY BEFORE STARTING THE INSTALLATION. CUT-OUT MARK Mark the cutout area. (See figures 8 and 12 through HOLES for dimensions.) Drill holes at the corners of area to be cut out to permit insertion of saw blade. (See figure 11.) •...
  • Page 7 Prepare air-cleaner cabinet for electrical connection as follows: Determine location of power supply source which will dictate the location of electrical wiring. Three knockouts (figure 15) are located in upper right-hand corner of cabinet. A built-in "J" type junction is included. Secure wiring with accepted hardware.
  • Page 8 11. Connect Power Wires. _.._ //Z/4I W HITE(SUPPLY) Connect black and white wires from power supply II _ to corresponding black and white wires in the air cleaner junction box. (See figure 18.) \\ _LACK CSUPPLY) Connect ground wire (green or bare wire) from power source to green grounding wire in junction box.
  • Page 9: Operation

    OPERATION SAFETY1NTERLOCK O N-OFF SWITCH SWITCH OPERATING LIGHT Turn on furnace or air conditioner to get air flow '\ //0oi through the duct. Press the lower section of "ON-OFF" rocker switch (Figure 21 ). Close grille by rotating into position the cabinet (fig.
  • Page 10 Figure 23 Figure 24 PREPARE THE WASH WATER: Flush cell frame along edges to dislodge any trapped dirt or lint. Place enough water a suitable wash Flush and rinse screenon both sides. container (figure 23) to cover the cell. Dissolve four ounces of automatic dishwasher Stand cell and screen up and allow them to drain...
  • Page 11: Troubleshooting

    REPLACING AN IONIZING WIRE If one or more ionizing wires in the cell should break, usually caused by accidental damage, it can be replaced as follows: Remove all pieces of broken wire. Make sure supports at each end are in good condition and not bent out of shape.
  • Page 12: Repair Parts

    REPAIR PARTS "14...
  • Page 13 Model Nos. 1OC1 3T-41 002 1 4C1 3T-41 002 2OC1 3T-41 002 WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION AS SHOWN IN THIS LIST. The PART NUMBER The PART DESCRIPTION The MODEL NUMBER The NAME OF ITEM - Electronic Air Cleaner Always Order by "Part Number"...
  • Page 14 WHITE-RODGERS White-Rodgers Division, Emerson Electric Co. Em 9797 Reavis Road, St. Louis, MO 63123 (314) 577-1300...

This manual is also suitable for:

10c13t-4100214c13t-41002

Table of Contents