  • Page 3 Preface Fujitsu would like to thank you for purchasing our ETERNUS DX60 S2 Disk storage system. The ETERNUS DX60 S2 Disk storage system is designed to be connected to Fujitsu (PRIMEQUEST or PRIMERGY) or non-Fujitsu servers. This manual describes the environmental requirements that are necessary to install and use the ETERNUS DX60 S2 Disk storage system.
  • Page 4: About This Manual

    A "FC card", "LAN card", "Network Interface Card (NIC)", or "SAS card" may be used instead, depending on the server and interface. • Trademark symbols such as ™ and ® are omitted in this document. ETERNUS DX60 S2 Disk storage system User’s Guide -Site Planning- Copyright 2012 FUJITSU LIMITED P3AM-5492-04ENZ0...
  • Page 5 - Be careful that no liquid seeps into the ETERNUS DX Disk storage system when using cleaners, etc. - Do not use alcohol or other solvents to clean the ETERNUS DX Disk storage system. Warning Layout Ribbon ETERNUS DX60 S2 Disk storage system User’s Guide -Site Planning- Copyright 2012 FUJITSU LIMITED P3AM-5492-04ENZ0...
  • Page 6: Table Of Contents

    LAN Connection ....................45 Power Supply Connection ................46 3.3.1 Input Power Supply Lines ......................46 3.3.2 UPS Connection ........................48 Power Synchronized Connections ..............49 ETERNUS DX60 S2 Disk storage system User’s Guide -Site Planning- Copyright 2012 FUJITSU LIMITED P3AM-5492-04ENZ0...
  • Page 7 Chapter 4 Rack and Optional Product Installation .......53 Rack Installation Requirements ............... 53 Installable Racks ....................54 4.2.1 Fujitsu Racks ..........................54 4.2.2 Non-Fujitsu Racks ........................54 Standard Installation Rules Before Shipment (Only for Regions Other than EMEA&I) ............56 4.3.1...
  • Page 8 Figure 3.10 Single-line power supply when connecting to a power socket and a UPS unit ......47 Figure 3.11 Power control using a power synchronized unit (when connecting one or two servers) ... 50 ETERNUS DX60 S2 Disk storage system User’s Guide -Site Planning- Copyright 2012 FUJITSU LIMITED P3AM-5492-04ENZ0...
  • Page 9 Installation diagram for 3.5" disks....................59 Figure 4.4 Disk installation example at shipment (2.5" type controller enclosure)........60 Figure 4.5 Disk installation example at shipment (3.5" type controller enclosure)........60 ETERNUS DX60 S2 Disk storage system User’s Guide -Site Planning- Copyright 2012 FUJITSU LIMITED P3AM-5492-04ENZ0...
  • Page 10 Specifications for the unit installation area ................55 Table 4.3 Priority order of 2.5" disk installation ..................57 Table 4.4 Priority order of 3.5" disk installation ..................58 ETERNUS DX60 S2 Disk storage system User’s Guide -Site Planning- Copyright 2012 FUJITSU LIMITED P3AM-5492-04ENZ0...
  • Page 11: Chapter 1 Hardware Configurations

    Multipath connection to a single server is not available. • Fujitsu recommends that the dual-controller types, in which the controller and expander are duplicated, be used in a system where a high level of reliability is required.
  • Page 12: Figure 1.2 Rear View Of A 2.5" Type Controller Enclosure (Single-Controller Type)

    (0 (Left), 1 (Right)) (0 (Left), 1 (Right)) DI (OUT) port DI (OUT) port Figure 1.3 Rear view of a 2.5" type controller enclosure (dual-controller type) ETERNUS DX60 S2 Disk storage system User’s Guide -Site Planning- Copyright 2012 FUJITSU LIMITED P3AM-5492-04ENZ0...
  • Page 13: Figure 1.4 Top View Of A 2.5" Type Controller Enclosure

    Front view of a 3.5" type controller enclosure (with front cover) 3.5" disk Figure 1.7 Front view of a 3.5" type controller enclosure (without front cover) ETERNUS DX60 S2 Disk storage system User’s Guide -Site Planning- Copyright 2012 FUJITSU LIMITED P3AM-5492-04ENZ0...
  • Page 14: Figure 1.8 Rear View Of A 3.5" Type Controller Enclosure (Single-Controller Type)

    (0 (Left), 1 (Right)) (0 (Left), 1 (Right)) DI (OUT) port DI (OUT) port Figure 1.9 Rear view of a 3.5" type controller enclosure (dual-controller type) ETERNUS DX60 S2 Disk storage system User’s Guide -Site Planning- Copyright 2012 FUJITSU LIMITED P3AM-5492-04ENZ0...
  • Page 15: Controllers

    ETERNUS DX Disk storage system. ■ Cache memory Cache memory enables high speed processing by storing frequently used data. The cache memory capacity for each controller is 1GB. ETERNUS DX60 S2 Disk storage system User’s Guide -Site Planning- Copyright 2012 FUJITSU LIMITED P3AM-5492-04ENZ0...
  • Page 16: Figure 1.12 Host Interface Port (Fc Model)

    Table 1.1 Host interface port specifications Number of ports for Interface Transfer speed (max.) Connector type each controller 4Gbit/s iSCSI 1Gbit/s RJ-45 3Gbit/s miniSAS (SFF8088) ETERNUS DX60 S2 Disk storage system User’s Guide -Site Planning- Copyright 2012 FUJITSU LIMITED P3AM-5492-04ENZ0...
  • Page 17: Table 1.2 Di Port Specifications

    The following table shows the PWC port specifications. Table 1.4 PWC port specifications Number of ports for Interface Connector type each controller RS232C D-sub9 pin ETERNUS DX60 S2 Disk storage system User’s Guide -Site Planning- Copyright 2012 FUJITSU LIMITED P3AM-5492-04ENZ0...
  • Page 18: Power Supply Units

    Figure 1.16 Front view of a drive enclosure (with front cover) • Without front cover 3.5" disk Figure 1.17 Front view of a drive enclosure (without front cover) ETERNUS DX60 S2 Disk storage system User’s Guide -Site Planning- Copyright 2012 FUJITSU LIMITED P3AM-5492-04ENZ0...
  • Page 19: Figure 1.18 Rear View Of A Drive Enclosure (Single-Expander Type)

    Power supply unit (PSU#0) (PSU#1) Figure 1.19 Rear view of a drive enclosure (dual-expander type) ● Top view Figure 1.20 Top view of a drive enclosure ETERNUS DX60 S2 Disk storage system User’s Guide -Site Planning- Copyright 2012 FUJITSU LIMITED P3AM-5492-04ENZ0...
  • Page 20: Expanders

    Two power supply units are installed in each drive enclosure. Each power supply unit contains fans. Figure 1.23 Power supply unit (drive enclosure) ETERNUS DX60 S2 Disk storage system User’s Guide -Site Planning- Copyright 2012 FUJITSU LIMITED P3AM-5492-04ENZ0...
  • Page 21: Enclosure Connection Path

    Figure 1.24 Enclosure connection path (dual-controller type) A connection path is not duplicated in a single-controller type. DI: Drive Interface port Figure 1.25 Enclosure connection path (single-controller type) ETERNUS DX60 S2 Disk storage system User’s Guide -Site Planning- Copyright 2012 FUJITSU LIMITED P3AM-5492-04ENZ0...
  • Page 22: Disks

    Storage media Storage capacity Speed SAS disks Hard disk 300GB, 450GB, 600GB 15,000rpm Serial Attached Nearline SCSI (3Gbit/s) Hard disk 1TB, 2TB, 3TB 7,200rpm SAS disks ETERNUS DX60 S2 Disk storage system User’s Guide -Site Planning- Copyright 2012 FUJITSU LIMITED P3AM-5492-04ENZ0...
  • Page 23: Power Distribution Units (Only For Regions Other Than Emea&I)

    AC200 - 240V Phase Single Frequency 50Hz/60Hz Input cable Connection type IEC60320-C13 ↔ NEMA L6-15P Length Quantity Output cable Connection type IEC60320-C13 ↔ IEC60320-C14 Length Quantity ETERNUS DX60 S2 Disk storage system User’s Guide -Site Planning- Copyright 2012 FUJITSU LIMITED P3AM-5492-04ENZ0...
  • Page 24: Figure 1.27 Power Distribution Unit (Ac200-240V, 2U, Max 6 Enclosures Connection)

    Power distribution unit for DX60 S2 (AC200-240V, 2U, Max 8 enclosures connection) There are 16 outlets. Outlets (OUTPUT) Figure 1.28 Power distribution unit (AC200-240V, 2U, Max 8 enclosures connection) ETERNUS DX60 S2 Disk storage system User’s Guide -Site Planning- Copyright 2012 FUJITSU LIMITED P3AM-5492-04ENZ0...
  • Page 25: Table 1.10 Power Distribution Unit (Ac200-240V, 2U, Max 8 Enclosures Connection) And Provided Ac Cable Specifications

    AC200 - 240V Phase Single Frequency 50Hz/60Hz Input cable Connection type Straight-through ↔ NEMA L6-30P Length Quantity IEC60320-C13 ↔ IEC60320-C14 Output cable Connection type Length Quantity ETERNUS DX60 S2 Disk storage system User’s Guide -Site Planning- Copyright 2012 FUJITSU LIMITED P3AM-5492-04ENZ0...
  • Page 26: Chapter 2 Eternus Dx Disk Storage System Installation

    EMEA&I region IEC60320-C14G (supplied as standard) For AC200V connections: Plug type Regions other NEMA L6-15P (supplied as standard) than EMEA&I For AC100V/AC200V connections: IEC60320-C14 (optional) ETERNUS DX60 S2 Disk storage system User’s Guide -Site Planning- Copyright 2012 FUJITSU LIMITED P3AM-5492-04ENZ0...
  • Page 27 3.5" disk configuration. These values are measured when a single controller enclosure is configured in an environment in which the temperature is 23 ± 2°C. ETERNUS DX60 S2 Disk storage system User’s Guide -Site Planning- Copyright 2012 FUJITSU LIMITED P3AM-5492-04ENZ0...
  • Page 28: Package Size

    When an order for optional disks to be installed in the factory is placed, enclosures are shipped with the disks preinstalled. When optional disks are ordered without preinstallation, each disk is shipped in an individual package. ETERNUS DX60 S2 Disk storage system User’s Guide -Site Planning- Copyright 2012 FUJITSU LIMITED P3AM-5492-04ENZ0...
  • Page 29: Installation Area

    This section explains the installation area and the service area that are required for an ETERNUS DX Disk storage system that is installed in a Fujitsu 19-inch rack. Secure service areas that are 800mm or more in the front and rear of the ETERNUS DX Disk storage system.
  • Page 30: Installation Environment

    Contact your installation contractor for more details regarding earthquake countermeasure methods and how work should be conducted. ETERNUS DX60 S2 Disk storage system User’s Guide -Site Planning- Copyright 2012 FUJITSU LIMITED P3AM-5492-04ENZ0...
  • Page 31: Load Bearing Capacity For Floors

    In addition, make sure that the plug type of the power distribution unit fits the power socket when using an existing power socket. If the plug type does not fit the power socket, replace the socket. ETERNUS DX60 S2 Disk storage system User’s Guide -Site Planning- Copyright 2012 FUJITSU LIMITED P3AM-5492-04ENZ0...
  • Page 32: Table 2.3 Specifications For Power Cords Supplied With The Eternus Dx Disk Storage System (For The Emea&I Region)

    Used for connection NEMA L6-15P NEMA L6-15R 4.0m 250V 15A between the ETERNUS (Normal usage DX Disk storage system <12A) and the socket (IEC60320-C13 ↔ NEMA L6-15P) ETERNUS DX60 S2 Disk storage system User’s Guide -Site Planning- Copyright 2012 FUJITSU LIMITED P3AM-5492-04ENZ0...
  • Page 33: Table 2.5 Specifications For Power Distribution Unit For Dx60 S2

    Specifications for power distribution unit for DX60 S2 (AC200-240V, 2U, Max 8 enclosures connection) Output Input Remarks Outlet type Plug type Socket type Cable length IEC60320-C13 NEMA L6-30P NEMA L6-30R 4.0m 250V 30A (Normal usage <24A) ETERNUS DX60 S2 Disk storage system User’s Guide -Site Planning- Copyright 2012 FUJITSU LIMITED P3AM-5492-04ENZ0...
  • Page 34: Required Number Of Outlets/Sockets

    Max 2 enclosures connection) Power distribution unit for DX60 S2 (AC200-240V, 2U, Max 6 enclosures connection) Power distribution unit for DX60 S2 (AC200-240V, 2U, Max 8 enclosures connection) ETERNUS DX60 S2 Disk storage system User’s Guide -Site Planning- Copyright 2012 FUJITSU LIMITED P3AM-5492-04ENZ0...
  • Page 35: Figure 2.2 Power Distribution Unit (1U)

    Power distribution unit for DX60 S2 (AC200-240V, 2U, Max 8 enclosures connection) Up to eight enclosures can be connected. Input (2 sockets) Output (12 or 16 outlets) Figure 2.3 Power distribution unit (2U) ETERNUS DX60 S2 Disk storage system User’s Guide -Site Planning- Copyright 2012 FUJITSU LIMITED P3AM-5492-04ENZ0...
  • Page 36: Circuit Protectors

    AC200 – 240V — 240V, 2U, Max 8 enclosures connection) – ETERNUS DX Disk storage system AC100 120V (without power distribution units) AC200 – 240V ETERNUS DX60 S2 Disk storage system User’s Guide -Site Planning- Copyright 2012 FUJITSU LIMITED P3AM-5492-04ENZ0...
  • Page 37: Breaking Characteristics

    100% 125% 150% 200% 400% 600% 800% 1000% No Trip 50 to 30 to 10 to 1.5 to 0.4 to 0.013 to 0.013 to 0.85 ETERNUS DX60 S2 Disk storage system User’s Guide -Site Planning- Copyright 2012 FUJITSU LIMITED P3AM-5492-04ENZ0...
  • Page 38: Figure 2.5 Example Of A Power Supply Connection Using A Power Distribution Unit (2U)

    Figure 2.6 or equivalent to D (IEC898). CURVE 200E 1000 0.01 0.001 1000 PERCENT LOAD (%) Figure 2.6 Power distribution unit (1U) breaking characteristics (graph) ETERNUS DX60 S2 Disk storage system User’s Guide -Site Planning- Copyright 2012 FUJITSU LIMITED P3AM-5492-04ENZ0...
  • Page 39: Figure 2.7 Example Of A Power Supply Connection Using A Power Distribution Unit (1U)

    To power supply facility To power supply facility CP: Circuit Protector Figure 2.7 Example of a power supply connection using a power distribution unit (1U) ETERNUS DX60 S2 Disk storage system User’s Guide -Site Planning- Copyright 2012 FUJITSU LIMITED P3AM-5492-04ENZ0...
  • Page 40: Figure 2.8 Eternus Dx Disk Storage System (Psu) Breaking Characteristics (Graph)

    Figure 2.9 Example of a power supply connection without power distribution units CAUTION • Only connect the ETERNUS DX Disk storage system to circuit protectors. ETERNUS DX60 S2 Disk storage system User’s Guide -Site Planning- Copyright 2012 FUJITSU LIMITED P3AM-5492-04ENZ0...
  • Page 41: Chapter 3 Connections

    Bidirectional CHAP • Jumbo Frame Enabling Jumbo Frame makes data transfer more efficient by increasing the amount of data that can be transferred for each Frame. ETERNUS DX60 S2 Disk storage system User’s Guide -Site Planning- Copyright 2012 FUJITSU LIMITED P3AM-5492-04ENZ0...
  • Page 42: Host Connection Path

    In a single path connection configuration, the path failover and load balancing functions are not supported. A multipath connection configuration is recommended to maintain availability when a problem occurs. ETERNUS DX60 S2 Disk storage system User’s Guide -Site Planning- Copyright 2012 FUJITSU LIMITED P3AM-5492-04ENZ0...
  • Page 43: Figure 3.1 Single Path Connection (Direct Connection)

    To use the load balancing function, four or more paths must be used to con- nect the server and the ETERNUS DX Disk storage system. ETERNUS DX60 S2 Disk storage system User’s Guide -Site Planning- Copyright 2012 FUJITSU LIMITED P3AM-5492-04ENZ0...
  • Page 44: Figure 3.3 Multipath Connection (Direct Connection)

    When a server is duplicated in a cluster configuration and the ETERNUS DX Disk storage sys- tem is shared by multiple servers, software to control the cluster configuration is required. ETERNUS DX60 S2 Disk storage system User’s Guide -Site Planning- Copyright 2012 FUJITSU LIMITED P3AM-5492-04ENZ0...
  • Page 45: Lan Connection

    In addition, the functions that are provided by the management/monitoring server on the LAN can be used. These functions include SNMP (device monitoring), SMTP (e-mail sending), and NTP (time correction). ETERNUS DX60 S2 Disk storage system User’s Guide -Site Planning- Copyright 2012 FUJITSU LIMITED P3AM-5492-04ENZ0...
  • Page 46: Power Supply Connection

    ETERNUS DX Power distribution unit Disk storage system Line 0 Line 1 Figure 3.6 Dual-line power supply when connecting to power sockets ETERNUS DX60 S2 Disk storage system User’s Guide -Site Planning- Copyright 2012 FUJITSU LIMITED P3AM-5492-04ENZ0...
  • Page 47: Figure 3.7 Dual-Line Power Supply When Connecting To Ups Units

    ETERNUS DX Power distribution unit Disk storage system Line 0 Figure 3.10 Single-line power supply when connecting to a power socket and a UPS unit ETERNUS DX60 S2 Disk storage system User’s Guide -Site Planning- Copyright 2012 FUJITSU LIMITED P3AM-5492-04ENZ0...
  • Page 48: Ups Connection

    If a UPS is used, make sure that it supplies power to all the enclosures. Configurations where the controller enclosure is powered by the UPS while the drive enclosure is powered directly from AC are not supported. ETERNUS DX60 S2 Disk storage system User’s Guide -Site Planning- Copyright 2012 FUJITSU LIMITED P3AM-5492-04ENZ0...
  • Page 49: Power Synchronized Connections

    The server UPS unit must have one unused outlet to connect to the power synchronized unit. ETERNUS DX60 S2 Disk storage system User’s Guide -Site Planning- Copyright 2012 FUJITSU LIMITED P3AM-5492-04ENZ0...
  • Page 50: Figure 3.11 Power Control Using A Power Synchronized Unit (When Connecting One Or Two Servers)

    Shutdown of all the server UPS units Issuance of command to turn off the ETERNUS DX Disk storage system from the power synchronized unit ETERNUS DX Disk storage system shutdown ETERNUS DX60 S2 Disk storage system User’s Guide -Site Planning- Copyright 2012 FUJITSU LIMITED P3AM-5492-04ENZ0...
  • Page 51: Figure 3.12 Power Control Using A Power Synchronized Unit (When Connecting Three Or More Servers)

    ETERNUS DX Disk storage system startup The server must be set to suspend server OS startup until the ETERNUS DX Disk storage system startup is complete. ETERNUS DX60 S2 Disk storage system User’s Guide -Site Planning- Copyright 2012 FUJITSU LIMITED P3AM-5492-04ENZ0...
  • Page 52 ETERNUS DX Disk storage system shutdown Refer to the manual that is provided with a power synchronized unit for details about connection configurations with power synchronized units and required settings. ETERNUS DX60 S2 Disk storage system User’s Guide -Site Planning- Copyright 2012 FUJITSU LIMITED P3AM-5492-04ENZ0...
  • Page 53: Chapter 4 Rack And Optional Product Installation

    In this case, secure a space of 1U or more at the bottom when installing the storage system. ETERNUS DX60 S2 Disk storage system User’s Guide -Site Planning- Copyright 2012 FUJITSU LIMITED P3AM-5492-04ENZ0...
  • Page 54: Installable Racks

    ETERNUS DX Disk storage system in non-Fujitsu racks is not covered by the war- ranty. If the ETERNUS DX Disk storage system needs to be installed in a non-Fujitsu rack, the follow- ing conditions must be satisfied. ■...
  • Page 55: Figure 4.1 Unit Installation Area

    Install air conditioning in order to ensure that the interior temperature of the rack satisfies the temperature conditions listed in "2.1 Installation Specifications" (page 26) "2.4.1 Air Conditioning" (page 30). ETERNUS DX60 S2 Disk storage system User’s Guide -Site Planning- Copyright 2012 FUJITSU LIMITED P3AM-5492-04ENZ0...
  • Page 56: Standard Installation Rules Before Shipment (Only For Regions Other Than Emea&I)

    This section explains the installation rules for a drive enclosure. ■ 2.5" type controller enclosure Drive enclosures cannot be connected. ■ 3.5" type controller enclosure Only one drive enclosure can be connected. ETERNUS DX60 S2 Disk storage system User’s Guide -Site Planning- Copyright 2012 FUJITSU LIMITED P3AM-5492-04ENZ0...
  • Page 57: Disks

    Up to twenty-four 2.5" disks can be installed in a 2.5" type controller enclosure. Install disks in the slots of a controller enclosure from Slot#0 to Slot#23 in ascending order according to the installation order in Table 4.3. ETERNUS DX60 S2 Disk storage system User’s Guide -Site Planning- Copyright 2012 FUJITSU LIMITED P3AM-5492-04ENZ0...
  • Page 58: Figure 4.2 Installation Diagram For 2.5" Disks

    450GB/15krpm × 1 Hot spare 600GB/15krpm × 2 RAID1 600GB/15krpm × 6 RAID1+0 600GB/15krpm × 6 RAID5 600GB/15krpm × 6 RAID6 600GB/15krpm × 1 Hot spare ETERNUS DX60 S2 Disk storage system User’s Guide -Site Planning- Copyright 2012 FUJITSU LIMITED P3AM-5492-04ENZ0...
  • Page 59: Disk Installation Examples

    ETERNUS DX Disk storage system is shipped from the factory with the disks installed in the enclosure. The following diagram shows an example of the installation order for optional disks. ETERNUS DX60 S2 Disk storage system User’s Guide -Site Planning- Copyright 2012 FUJITSU LIMITED P3AM-5492-04ENZ0...
  • Page 60: Figure 4.4 Disk Installation Example At Shipment (2.5" Type Controller Enclosure)

    3.5" SAS (600GB, hot spare) 3.5" Nearline SAS (2TB, RAID5) 3.5" Nearline SAS (2TB, hot spare) Figure 4.5 Disk installation example at shipment (3.5" type controller enclosure) ETERNUS DX60 S2 Disk storage system User’s Guide -Site Planning- Copyright 2012 FUJITSU LIMITED P3AM-5492-04ENZ0...
  • Page 61 However, Fujitsu shall assume no responsibility for any operational problems as the result of errors, omissions, or the use of information in this manual. • Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information in this manual. •...