Pioneer 504CMX - PDP - 50" Plasma Panel Command Reference Manual
Pioneer 504CMX - PDP - 50" Plasma Panel Command Reference Manual

Pioneer 504CMX - PDP - 50" Plasma Panel Command Reference Manual

Plasma display panel rs-232c commands
Hide thumbs Also See for 504CMX - PDP - 50" Plasma Panel:

Quick Links

PDP-504CMX
Plasma Display Panel
RS-232C Commands
C
P
M
O M M A N D
R O T O C O L
A N U A L
Manual Version 1.00
November 3, 2004
Pioneer Corporation
Pioneer Electronics (USA) Inc.
Industrial Solutions Business Group
loading

Summary of Contents for Pioneer 504CMX - PDP - 50" Plasma Panel

  • Page 1 PDP-504CMX Plasma Display Panel RS-232C Commands O M M A N D R O T O C O L A N U A L Manual Version 1.00 November 3, 2004 Pioneer Corporation Pioneer Electronics (USA) Inc. Industrial Solutions Business Group...
  • Page 2 Every precaution has been taken in the preparation of this manual. Although we tried to thoroughly check that all instructions and information in this manual are accurate and correct, Pioneer can not be and is not responsible, in whole or in part, for any damage or loss to your data and/or equipment that results from your use of this document or from any information contained herein including, but not limited to, any errors, omissions or typos that may have resulted in an incorrect operation or installation.
  • Page 3 RS-232C Adjustment Mode 5.5 RS-232C Adjustment Mode This display has a RS-232C terminal. It is possible to use a PC to make various adjustments and settings. 5.5.1 About the RS-232C Adjustment Mode 1) Adjustments in the RS-232C adjustment mode: • The adjustments are written to the same memory area as for the integrator mode (refer to section 5.4.4, ‘PICTURE, White Balance and SCREEN Position Adjustment Values Memory Area Tables’).
  • Page 4 RS-232C Adjustment Mode 5.5.2 Interface 1) Connector D-sub 9 pins (male) 2) Pin layout Pin No. Signal Pin No. Signal NC (not connected) NC (not connected) TxD (Transmit Data) NC (not connected) RxD (Receive Data) RTS (Request To Send) NC (not connected) NC (not connected) 3) Baud Rate 9600 bps (standard)
  • Page 5 RS-232C Adjustment Mode 5.5.3 ID Assignment After connecting to the PC, an ID is assigned. The ID is assigned from the PC. Commands: (ID CLEAR) ..Clears the assigned ID (ID SET) ..... Assigns an ID IDS is only effective when an ID is not assigned. Also, IDs are set starting from the set closest to the PC.
  • Page 6: Combination Connection

    RS-232C Adjustment Mode 5.5.4 Combination Connection When performing control and adjustment, it is convenient to connect several sets to one PC. By performing a combination connection and assigning IDs to the sets, it is possible to control and adjust several sets at the same time or separately.
  • Page 7 RS-232C Adjustment Mode Under the connection conditions shown below, operation using a combination cable is assured up to 16 sets. 1 Length of RS-232C cable connecting PC to PDP-504CMX/PDP-50MXE1/PDP-50MXE1-S: 5 m Conditions: 2 Combination cable length: 5 m each 3 Wire specifications for linking cable: Mini Din 6-pin straight (7 strand cable) For 1 strand, suitable for AWG28: Cross-section area = 0.08 mm ≠...
  • Page 8 RS-232C Adjustment Mode 5.5.5 List of RS-232C Commands How to read this Table • RS-232C adjustment validity : Indicates whether or not the RS-232C adjustment mode can be used. • Normal validity : Indicates whether or not the normal-operation mode can be used. •...
  • Page 9 RS-232C Adjustment Mode RS-232C Numerical Normal Adjustment Direct Command name AJY (232C integrator) Display Remarks Validity Validity Validity ¶ CTI: ### Displays the current CTI setting. ‡ CTRS00 CTI: OFF Sets CTI to OFF. ‡ CTRS01 CTI: ON Sets CTI to ON. ‡...
  • Page 10 RS-232C Adjustment Mode RS-232C Numerical Normal Adjustment Direct Command name AJY (232C integrator) Display Remarks Validity Validity Validity ¶ GRADATION: ####### Displays the current GRADATION setting ‡ GRAS01 GRADATION: GAMMA 2.0 Sets GRADATION to ‘GAMMA 2.0’. ‡ GRAS02 GRADATION: GAMMA 1.8 Sets GRADATION to ‘GAMMA 1.8’.
  • Page 11 RS-232C Adjustment Mode RS-232C Numerical Normal Adjustment Direct Command name AJY (232C integrator) Display Remarks Validity Validity Validity ¶ MIRROR MODE: ### Displays the current MIRROR MODE setting. ‡ MIRS00 MIRROR MODE: OFF Turns the MIRROR MODE OFF (normal display). ‡...
  • Page 12: Sub Volume

    RS-232C Adjustment Mode RS-232C Numerical Normal Adjustment Direct Command name AJY (232C integrator) Display Remarks Validity Validity Validity ¶ ¶ ######### Displays the current sub screen input function. ‡ ‡ SSIS01 INPUT1(SUB) Switches the sub screen to INPUT1. ‡ ‡ SSIS02 INPUT2(SUB) Switches the sub screen to INPUT2.
  • Page 13: Get Commands

    RS-232C Adjustment Mode 5.5.6 GET Commands What are GET commands? • They are commands for outputting TXD such as adjustment data from the internal microcomputer of the plasma display to a PC. • Adjustment data and the like is output in ASCII code. Note Command names are given inside brackets <...
  • Page 14 RS-232C Adjustment Mode 2) (GET PICTURE DATA: Gets integrator/PICTURE data.) Order Data contents Size Remarks CONTRAST 3 Byte BRIGHTNESS 3 Byte C. DETAIL R (RED) 3 Byte C. DETAIL Y (YELLOW) 3 Byte C. DETAIL G (GREEN) 3 Byte C.
  • Page 15 RS-232C Adjustment Mode 5) (GET STATUS SETUP: Gets menu and integrator SETUP data.) Order Data contents Size Output Remarks GRADATION 1 Byte 1: GAMMA 2.0 2: GAMMA 1.8 3: GAMMA 2.2 4: DRE MID 5: DRE HIGH 6: DRE LOW 7: HIGH CNT.
  • Page 16 RS-232C Adjustment Mode 6) (GET STATUS OPTION: Gets menu and integrator OPTION data.) Order Data contents Size Output Remarks ENERGY SAVE 1 Byte 1: STANDARD 2: MODE 1 3: MODE 2 4: MODE 3 5: AUTO ORBITER 1 Byte 0: OFF 1: ON MASK CONTROL...
  • Page 17 RS-232C Adjustment Mode Check Sum This is data to which 2-Byte ASCII code is added to a data group returned by a GET command. PC side GET command 02 (hex) 2 Byte 3 Byte 03 (hex) Set side GET command Data Check Sum 02 (hex)
  • Page 18 PDP-504CMX RS-232C Command Protocol Manual Pioneer Electronics (USA) Inc. Industrial Solutions Business Group 2265 East 220 Street Long Beach, California 90810 United States of America (310) 952-2000 http://www.pioneerelectronics.com...

This manual is also suitable for:

Pdp-504cmx