Asus ESC4000 G2 GPU Quick Start Manual

Cache vault accessory kit
Hide thumbs Also See for ESC4000 G2 GPU:
Table of Contents

Quick Links

Cache Vault Accessory Kit

Quick Start Guide

Copyright © 2012 ASUSTeK COMPUTER INC. All Rights Reserved.
No part of this manual, including the products and software described in it, may be reproduced,
transmitted, transcribed, stored in a retrieval system, or translated into any language in any form or by any
means, except documentation kept by the purchaser for backup purposes, without the express written
permission of ASUSTeK COMPUTER INC. ("ASUS").
Product warranty or service will not be extended if: (1) the product is repaired, modified or altered, unless
such repair, modification of alteration is authorized in writing by ASUS; or (2) the serial number of the
product is defaced or missing.
ASUS PROVIDES THIS MANUAL "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS
OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OR CONDITIONS OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL ASUS, ITS
DIRECTORS, OFFICERS, EMPLOYEES OR AGENTS BE LIABLE FOR ANY INDIRECT, SPECIAL,
INCIDENTAL, OR CONSEQUENTIAL DAMAGES (INCLUDING DAMAGES FOR LOSS OF PROFITS,
LOSS OF BUSINESS, LOSS OF USE OR DATA, INTERRUPTION OF BUSINESS AND THE LIKE),
EVEN IF ASUS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES ARISING FROM ANY
DEFECT OR ERROR IN THIS MANUAL OR PRODUCT.
SPECIFICATIONS AND INFORMATION CONTAINED IN THIS MANUAL ARE FURNISHED FOR
INFORMATIONAL USE ONLY, AND ARE SUBJECT TO CHANGE AT ANY TIME WITHOUT NOTICE,
AND SHOULD NOT BE CONSTRUED AS A COMMITMENT BY ASUS. ASUS ASSUMES NO
RESPONSIBILITY OR LIABILITY FOR ANY ERRORS OR INACCURACIES THAT MAY APPEAR IN THIS
MANUAL, INCLUDING THE PRODUCTS AND SOFTWARE DESCRIBED IN IT.
Products and corporate names appearing in this manual may or may not be registered trademarks or
copyrights of their respective companies, and are used only for identification or explanation and to the
owners' benefit, without intent to infringe.
Contents
Package contents.................................................................................. 2
Standard installation of Cache Vault power module .................................3
server systems .........................................................................................5
15060-09V10000
First Edition (V1) T7843
November 2012

Chapters

Table of Contents
loading

Summary of Contents for Asus ESC4000 G2 GPU

  • Page 1: Table Of Contents

    Product warranty or service will not be extended if: (1) the product is repaired, modified or altered, unless such repair, modification of alteration is authorized in writing by ASUS; or (2) the serial number of the product is defaced or missing.
  • Page 2: Package Contents

    ® caps*) ASUS Accessory Kit Steel bracket (1 x Full- Screws (3): 2 screws for the Screws (4): 3 screws** for ASUS height, 1 x Half-height) steel bracket steel CVPM clip holder * Use these screws (2) and screw caps when installing LSI steel ®...
  • Page 3: Installing The Cache Vault Kit On The Holder And The Pike Card

    (2). Standard installation of Cache Vault power module Some specific ASUS server systms have a specific space for installing Cache Valut Power module, allowing you the use of all your system’s expansion slots. For generally standard installation, please follow the steps below.
  • Page 4: Installing The Cache Vault Flash Module On The Pike 2208 Card

    Install the Cache Vault Power Module on your server system. The images shown below are for reference only. Installed on a 2U server system. Installed on a 5U server system. Installing the Cache Vault Flash Module on the PIKE 2208 card Place the PIKE 2208 card on a flat, stable surface.
  • Page 5: Installing The Cache Vault Kit On Specific Asus Server Systems

    After installing the Cache Vault Falsh Module on the PIKE 2208 card, and installing the Cache Vault Power Module on the steel CVPM clip and holder, install these two assemblies to the specific ASUS server systems as instructed below. Installing the kit on RS720-X7/RS8, RS720-E7/RS12, RS720-E7/...
  • Page 6: Installing The Kit On Rs920-E7/Rs8, Rs926-E7/Rs8 Server Systems

    Align the two screws on the side of the steel CVPM holder installed with the Cache Vault Power Module to the screw holes of the full-height steel bracket. Secure the holder assembly with the bundled screws (3). Place the holder assembly into the system and secure it with the screw removed earlier in step 1.
  • Page 7: Installing The Kit On Esc4000 G2 Gpu Server System

    Align the three screw holes on the LSI® steel CVPM clip to the three screw holes on the bracket, and secure the clip with the bundled screws (4). Install the Cache Vault Power Module to the clip and connect the 42’’...
  • Page 8 Take out the riser card bracket from the right side of the server system. Align the screw holes on the holder assembly to the screws holes on the bracket, then secure the holder assembly with a screw. Put the cable through the hole on the bracket.
  • Page 9 台端應自行承擔使用本使用手冊的所有風險。 台端明確了解並同意,華碩、華 碩之授權人及其各該主管、董事、員工、代理人或關係企業皆無須為您因本使用手 冊、或因使用本使用手冊、或因不可歸責於華碩的原因而無法使用本使用手冊或其 任何部分而可能產生的衍生、附隨、直接、間接、特別、懲罰或任何其他損失(包 括但不限於利益損失、業務中斷、資料遺失或其他金錢損失)負責,不論華碩是否 被告知發生上開損失之可能性。 由於部分國家或地區可能不允許責任的全部免除或對前述損失的責任限制,所以 前述限制或排除條款可能對您不適用。 台端知悉華碩有權隨時修改本使用手冊。本產品規格或驅動程式一經改變,本使 用手冊將會隨之更新。本使用手冊更新的詳細說明請您造訪華碩的客戶服務網 http:// support.asus.com,或是直接與華碩資訊產品技術支援專線 0800-093-456 聯絡。 於本使用手冊中提及之第三人產品名稱或內容,其所有權及智慧財產權皆為各別 產品或內容所有人所有且受現行智慧財產權相關法令及國際條約之保護。 當下列兩種情況發生時,本產品將不再受到華碩之保固及服務: (1) 本產品曾經過非華碩授權之維修、規格更改、零件替換或其他未經過華碩 授權的行為。 (2)本產品序號模糊不清或喪失。 目錄 包裝盒內容物 ..................2 安裝 Cache Vault 套件至支架與 PIKE 控制卡 ........... 3 安裝 Cache Vault 電源模組至 CVPM 鐵件夾與支架 ......3 Cache Vault 電源模組一般標準安裝...
  • Page 10: 包裝盒內容物

    包裝盒內容物 ® ® MegaRAID Cache Vault Accessory Kit 組件 Cache Vault 快閃記憶體模組 螺絲(1):Cache Vault 快閃記 Cache Vault 電源模組 (Cache Vault Flash Module) 憶體模組專用螺絲(3 顆) (Cache Vault Power Module) (CVFM02) (CVPM02) ® ® 24 吋纜線延長線 CVPM 鐵件夾 螺絲(2):LSI CVPM 鐵件夾 (24”Cable extender) (Steel CVPM clip/holder)...
  • Page 11: 安裝 Cache Vault 套件至支架與 Pike 控制卡

    安裝 Cache Vault 套件至支架與 PIKE 控制卡 首先,我們先將 Cache Vault 快閃記憶體模組安裝至 PIKE 2208 控制卡,以及將 Cache Vault 電源模組安裝至專用支架,請依照以下的說明進行。 安裝 Cache Vault 電源模組至 CVPM 鐵件夾與支架 ® 1. 取出華碩 CVPM 鐵件夾專用支 2. 取出 LSI CVPM 鐵件夾以供固定 架,找到上面三個螺絲孔位。 Cache Vault 電源模組。 ® 3. 翻轉 LSI CVPM 鐵件夾與專用支...
  • Page 12: 安裝 Cache Vault 快閃記憶體模組至 Pike 2208 控制卡

    2. 接著就可以將 Cache Vault 電源模組裝入各型伺服器系統中。 因各型伺服器不同,以下圖示為僅供安裝介面卡時的示意參考使用。 裝入 2U 伺服器。 裝入 5U/ 直立式伺服器。 安裝 Cache Vault 快閃記憶體模組至 PIKE 2208 控制卡 1. 取出 PIKE 2208 控制卡,放置 在平坦的桌面上,找到上面三 個螺絲安裝孔位。 2. 然後取出 Cache Vault 快閃記憶體模 組,找到上面三根螺絲安裝腳座。 3. 將 Cache Vault 快閃記憶體模組 翻轉至背面,然後將三根安裝 腳座對準 PIKE 2208 控制卡上 的安裝孔位,並從控制卡背面...
  • Page 13: Cache Vault 電源模組安裝至特定華碩伺服器

    Cache Vault 電源模組安裝至特定華碩伺服器 當安裝好 Cache Vault 快閃記憶體模組的 PIKE 2208 控制卡,以及裝上支架的 Cache Vault 電源模組後,接著就可以依照以下的說明,將這兩個組件裝至下列特定 的華碩伺服器系統裡。 安裝至 RS720-X7/RS8、RS720-E7/RS12、RS720-E7/ RS12-E 伺服器 1. 找到位於伺服器系統機殼右側的螺絲 安裝孔位。 2. 取出已裝上 Cache Vault 電源模組鐵件 夾的支架,如右圖所示,將此支架裝 入機殼側邊內側,並鎖上螺絲,然後 螺絲的位置 連接 42 吋纜線延長線。 3. 然後,再將延長線的另一端則連接至 Cache Vault 快閃記憶體模組上面的插 座。 4. 接著將 PIKE 2208 控制卡裝回系統中,並 依照箭頭所示的方向,整理好延長線的線...
  • Page 14: 安裝至 Rs920-E7/Rs8、Rs926-E7/Rs8 伺服器

    2. 取出已裝上 Cache Vault 電源模組鐵件 夾的支架,並於支架側邊鎖上全高擋 板(使用螺絲(3) 安裝)。 3. 裝上此支架至機殼內,並鎖上先前放 置一旁的螺絲,完成固定。 4. 將已裝好 Cache Vault 快閃記憶體模組 的 PIKE 2208卡裝入系統,並將 Cache Vault 電源模組上的纜線連接至 Cache Vault 快閃記憶體模組上的插座,如右 圖所圈處。 5. 最後,將纜線以醋酸膠帶連貼於底座 上,完成安裝。 安裝至 RS920-E7/RS8、RS926-E7/RS8 伺服器 1. 從系統中取出轉接卡,並放置於平坦 的桌面上,找到如右圖所示的三個螺 絲孔位。 若想要了解更多關於如何拆裝轉接卡的步驟,請參考伺服器系統使用手 冊上的說明。 Cache Vault Accessory Kit 快速安裝手冊...
  • Page 15: 安裝至 Esc4000 G2 Gpu 伺服器

    ® 2. 取出 LSI CVPM 鐵件夾(不需裝上 專用支架),使用產品包裝內附的螺 絲,如右圖所示將此鐵件夾使用三顆 鐵件夾專用螺絲(4) 從背面鎖在轉接卡 上面。 3. 接著裝上 Cache Vault 電源模組,並連 接 42 吋纜線延長線。 4. 然後,將延長線的另一端連接至 Cache Vault 快閃記憶體模組的插座。 5. 將 PIKE 2208 控制卡裝上擴充槽,再 將轉接卡裝回系統內(如右圖箭頭所 示)。然後將多餘的延長線整理好, 埋入 PIKE 2208 控制卡旁的縫隙中, 完成安裝。 PIKE 2208 卡 若想要了解更多關於如何拆裝轉接卡的步驟,請參考伺服器系統使用手 冊上的說明。...
  • Page 16 2. 取出系統內右側的擴充卡支撐架,將 此支架裝入支撐架裡並鎖上一顆螺絲 固定。 若想了解更多關於如何拆裝擴 充卡支撐架的步驟,請參考伺 服器系統使用手冊上的說明。 3. 再將纜線穿過右圖中的走線孔(圈選 處)。 4. 將擴充卡支撐架裝回系統中,並鎖上 螺絲固定。 若想了解更多關於如何安裝轉 接卡的步驟,請參考伺服器系 統使用手冊上的說明。 5. 連接纜線至已裝在 PIKE 2208卡上的 Cache Vault 快閃記憶體模組上面的插 座。 6. 接著如右圖所示,將 PIKE 2208 卡裝 入中央的轉接卡。 7. 最後,請依照伺服器系統使用手冊內 的安裝說明,將轉接卡裝回系統內, 完成安裝。 Cache Vault Accessory Kit 快速安裝手冊...

Table of Contents