HP A3550A - High Availability Disk Arrays Model 20 Storage Enclosure Installation Manual

Storage processor
Hide thumbs Also See for A3550A - High Availability Disk Arrays Model 20 Storage Enclosure:

Quick Links

Hewlett-Packard Storage Processor (SP)
Hewlett-Packard SPs are customer installable and replaceable. A replacement SP must be the same type as the SP being
replaced.
The locations of the SPs in the 30-slot disk arrays are shown in Figure 1.
.
SP-A
Install an SP by performing the following steps. Place a check in the appropriate
Step 1:
Observe antistatic precautions
An SP is shipped with an ESD kit containing:
ESD wrist strap
ESD conductive sheet
Ground the ESD wrist strap to the metal edge above the
rear retaining screws and fasten the strap to your wrist.
Installation Guide
Rear view, top of the disk array
Figure 1.
Step 2:
as the step is completed.
Prepare to install the SP
Remove the replacement SP from its shipping carton
and place it on a suitable antistatic work surface or the
ESD conductive sheet.
Array power can be left on during SP removal and
replacement.
Remove the failed SP.
Remove the memory modules from the failed SP.
Insert memory modules in the SIMM connectors on the
SP to be installed.
See the
SIMM removal and replacement.
SP-B
chapter in the
for more information about
loading