Honeywell 4820HDHM User Manual

Honeywell 4820HDHM User Manual

2d cordless imaging system
Hide thumbs Also See for 4820HDHM:
Table of Contents
2020/4820/4820i
2D Cordless Imaging System
User's Guide
Table of Contents
loading

Summary of Contents for Honeywell 4820HDHM

  • Page 1 2020/4820/4820i 2D Cordless Imaging System User’s Guide ™...
  • Page 2 Disclaimer Honeywell International Inc. (“HII”) reserves the right to make changes in speci- fications and other information contained in this document without prior notice, and the reader should in all cases consult HII to determine whether any such changes have been made. The information in this publication does not repre- sent a commitment on the part of HII.
  • Page 3 2. This device must accept any interference received, including interference that may cause undesired operation. Caution: Any changes or modifications made to this equipment not expressly approved by Honeywell may void the FCC authorization to operate this equipment. UL Statement UL listed: UL60950-1.
  • Page 4 5627 BT Eindhoven The Netherlands Honeywell shall not be liable for use of our product with equipment (i.e., power supplies, personal computers, etc.) that is not CE marked and does not comply with the Low Voltage Directive. This equipment is intended for...
  • Page 5 The crossed out wheeled bin symbol informs you that the product should not be disposed of along with municipal waste and invites you to use the appropriate separate take-back systems for product disposal. If you need more information on the collection, reuse, and recycling systems, please contact your local or regional waste administration.
  • Page 6 International CAUTION: RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. The battery should be disposed of by a qualified recycler or hazardous materials handler. Do not incinerate the battery or dispose of the battery with general waste materials. Eye Safety Statement This device has been tested in accordance with IEC60825-1 LED safety, and has been certified to be a Class 1 LED device.
  • Page 7: Solids And Water Protection

    Solids and Water Protection The 4820 has a rating of IP41, immunity of foreign particles and dripping water. The 4820i has a rating of IP54, immunity of foreign particles and sprayed water. Patents Please refer to product packaging for patent information.
  • Page 8 Required Safety Labels Scanner Compliance Label locations Item Number, Serial Number and Revision Information location...
  • Page 9 Base Compliance Label locations Item Number, Serial Number and Revision Information location...
  • Page 11: Table Of Contents

    Table of Contents Chapter 1 - Getting Started About This Manual ............1-1 Unpacking the System ..........1-1 Image Scanner Models ..........1-1 Cordless System: Main Components ......1-2 About the Battery ............1-2 Proper Disposal of the Battery ........1-3 Connecting the Base ...........
  • Page 12 Keyboard Modifiers............2-13 RS-232 Baud Rate ..........2-16 RS-232 Word Length: Data Bits, Stop Bits, and Parity ............2-16 RS-232 Receiver Time-Out ........ 2-17 RS-232 Handshaking .......... 2-18 Host ACK Selection ..........2-18 Host ACK Enable ..........2-20 Wand Emulation ............2-21 Wand Emulation Connection ......
  • Page 13 Single Image Scanner Operation ........ 3-5 Locked Link Mode - Single Image Scanner ..3-6 Open Link Mode - Single Image Scanner .... 3-6 Override Locked Image Scanner ......3-6 Multiple Image Scanner Operation......3-7 Image Scanner Name ..........3-7 Image Scanner Report ..........
  • Page 14 Good Read Delay ............4-3 User-Specified Good Read Delay........4-3 Serial Trigger Modes ...........4-4 Manual/Serial Trigger, Low Power ......4-4 Scan Stand Mode ............4-6 Scan Stand Symbol ..........4-6 Presentation Mode............4-7 Presentation LED Behavior after Decode ..... 4-7 Presentation Sensitivity ........4-8 Streaming Presentation™...
  • Page 15 Chapter 5 - Data Editing Prefix/Suffix Overview ..........5-1 To Add a Prefix or Suffix: ........5-1 To Clear One or All Prefixes or Suffixes: ....5-2 To Add a Carriage Return Suffix to All Symbologies ..........5-3 Prefix Selections ........... 5-4 Suffix Selections ...........
  • Page 16 Code 93 ..............7-11 Code 93 Code Page ........... 7-11 Straight 2 of 5 Industrial (three-bar start/stop) ... 7-12 Straight 2 of 5 IATA (two-bar start/stop) ....7-13 Matrix 2 of 5 ............... 7-14 Code 11 ..............7-15 Code 128 ..............7-16 ISBT 128 Concatenation ........
  • Page 17 Postal Codes ............. 7-39 Intelligent Mail Barcode ........7-39 ID-tag (UPU 4-State) .......... 7-40 Postnet ............... 7-40 Planet Code ............7-41 British Post ............7-42 Canadian Post ............ 7-42 Kix (Netherlands) Post ........7-42 Australian Post ........... 7-42 Japanese Post ............ 7-44 China Post ............
  • Page 18 OCR Templates ............9-3 Creating an OCR Template ........9-3 Stringing Together Multiple Formats (Creating “Or” Statements) ......9-5 OCR User-Defined Variables........9-6 Reading Multi-Row OCR ........9-7 OCR Check Character..........9-7 OCR Modulo 10 Check Character ......9-8 OCR Modulo 36 Check Character ......9-8 OCR User-Defined Check Character......9-8 Weighting Options ..........
  • Page 19 QuickView ..............11-6 Installing QuickView from the Web ..... 11-6 Temporary QuickView Configuration ......11-7 Chapter 12 - Serial Programming Commands Conventions .............. 12-1 Menu Command Syntax..........12-1 Query Commands ..........12-2 Concatenation of Multiple Commands ....12-2 Responses ............12-3 Examples of Query Commands ......
  • Page 20 Chapter 14 - Maintenance Repairs ..............14-1 Maintenance ..............14-1 Cleaning the Device ..........14-1 Inspecting Cords and Connectors ...... 14-1 Replacing the 2020 Interface Cable: ....14-2 Assembling the Battery Charge Sleeve Kit....14-3 Troubleshooting the Base..........14-4 Troubleshooting the Image Scanner......14-4 Chapter 15 - Customer Support Technical Assistance ..........15-1 Online Technical Assistance .......
  • Page 21: Chapter 1 - Getting Started

    4820/4820i. Product specifications, dimensions, warranty, and customer sup- port information are also included. Honeywell barcode image scanners are factory programmed for the most com- mon terminal and communications settings. If you need to change these set- tings, programming is accomplished by scanning the barcodes in this guide.
  • Page 22: Cordless System: Main Components

    Cordless System: Main Components Battery Contained in Handle Image Scanner 2020 Base About the Battery We recommend use of Hand Held Products Li-ion battery backs. Use of any non-Hand Held Products battery may result in damage not cov- ered by the warranty. Power is supplied to the cordless image scanner by a rechargeable battery that is integrated in the image scanner handle.
  • Page 23: Proper Disposal Of The Battery

    Replace it after the battery is unable to hold an adequate charge. • If you are not sure if the battery or charger is working properly, send it to Honeywell International Inc. or an authorized service center for inspection. Refer to Customer Support on page 15-1 for additional information.
  • Page 24: Connecting The Base With Keyboard Wedge

    For additional USB programming and technical information, refer to the Honey- well “USB Application Note,” available at www.honeywell.com/aidc Connecting the Base with Keyboard Wedge 1. Turn off power and disconnect the keyboard cable from the back of the ter- minal/computer.
  • Page 25 2. Connect the appropriate interface cable to the base and to the terminal/ computer and keyboard. Make sure the cables are secured in the wireways in the bottom of the base and that the base sits flat on a horizontal surface. 3.
  • Page 26: Connecting The Base With Rs-232 Serial Port

    Connecting the Base with RS-232 Serial Port 1. Turn off power to the terminal/computer. 2. Connect the appropriate interface cable to the base. Make sure the cables are secured in the wireways in the bottom of the base and that the base sits flat on a horizontal surface.
  • Page 27: Linking Image Scanner To Base

    3. Connect the appropriate interface cable to the base. Make sure the cables are secured in the wireways in the bottom of the base and that the base sits flat on a horizontal surface. Note: For the base to work properly, you must have the correct cable for your type of computer.
  • Page 28: Communication Between The Cordless System And The Host

    is the first time that the image scanner and base are linked, both devices emit a short chirp when their radios link. At this point, you are set to one image scan- ner to one base. Image Scanner Green LED 2020 Base Red LED 1.
  • Page 29: Reading Techniques

    When data is scanned, the data is sent to the host system via the base unit. The cordless image scanner recognizes data acknowledgement (ACK) from the base unit. If it cannot be determined that the data has been properly sent to the base, the image scanner issues an error indication.
  • Page 30 Linear barcode 2D Matrix symbol The aiming beam is smaller when the image scanner is closer to the code and larger when it is farther from the code. Symbologies with smaller bars or ele- ments (mil size) should be read closer to the unit. Symbologies with larger bars or elements (mil size) should be read farther from the unit.
  • Page 31: Chapter 2 - Programming The Interface

    Programming the Interface Introduction Chapter 1 describes connecting the base to the computer with the appropriate interface cable. This chapter describes how to program your system for the desired interface. Programming the Interface - Plug and Play Plug and Play barcodes provide instant image scanner set up for commonly used interfaces.
  • Page 32: Wand Emulation Plug & Play

    RS-232 The RS-232 Interface barcode is used when connecting to the serial port of a PC or terminal. The following RS-232 Interface barcode also programs a car- riage return (CR) and a line feed (LF) suffix, baud rate, and data format as indi- cated below.
  • Page 33: Ibm 4683 Ports 5B, 9B, And 17 Interface

    IBM 4683 Ports 5B, 9B, and 17 Interface Scan one of the following “Plug and Play” codes to program the image scanner for IBM 4683 Port 5B, 9B, or 17. Note: After scanning one of these codes, you must power cycle the cash register.
  • Page 34: Ibm Surepos

    IBM SurePos Scan one of the following “Plug and Play” codes to program the image scanner for IBM SurePos (USB Handheld image scanner) or IBM SurePos (USB Table- top imager). Note: After scanning one of these codes, you must power cycle the cash register.
  • Page 35: Usb Pc Or Macintosh Keyboard

    Scan the following code to program the image scanner to emulate a regular RS- 232-based COM Port. If you are using a Microsoft® Windows® PC, you will need to download a driver from the Honeywell website (www.honeywell.com/ aidc). The driver will use the next available COM Port number. Apple® Macin- tosh computers recognize the image scanner as a USB CDC class device and automatically uses a class driver.
  • Page 36: Serial Wedge

    CTS/RTS Emulation CTS/RTS Emulation On * CTS/RTS Emulation Off ACK/NAK Mode ACK/NAK Mode On * ACK/NAK Mode Off Serial Wedge To set up the serial wedge terminal ID, use the serial terminal ID 050 and follow the instructions on page 2-6.
  • Page 37 For example, an IBM AT terminal has a Terminal ID of 003. You would scan the Terminal ID barcode, then 0, 0, 3 from the Programming Chart inside the back cover of this manual, then Save. If you make an error while scanning the digits (before scanning Save), scan the Discard code on the Programming Chart,...
  • Page 38: Supported Terminals

    Supported Terminals Terminal Terminal Model(s) 3496, 3497, 122 key 3496, 3497, 102 key VT510, 520, 525 (PC style) VT510, 520, 525 (DEC style LK411) Esprit 200, 400 Heath Zenith PC, AT 003 * Heath Zenith Vectra 003 * Vectra PS/2 25, 30, 77DX2 AT, PS/2 30–286, 50, 55SX, 60, 003 * 70, 70–061, 70–121, 80...
  • Page 39 Supported Terminals Terminal Terminal Model(s) Telex 88 key 078, 078A, 79, 80, 191, 196, 1191,1192, 1471, 1472, 1476, 1477, 1483 Telex 88 key Data Entry Keyboard Telex 102 key 078, 078A, 79, 80, 191, 196, 1191,1192, 1471, 1472, 1476, 1477, 1483 Telex 122 key 078, 078A, 79, 80, 191, 196, 1191,1192, 1471, 1472, 1476,...
  • Page 40: Keyboard Country

    Keyboard Country Scan the appropriate country code below to program the keyboard for your country. As a general rule, the following characters are supported, but need special care for countries other than the United States: @ | $ # { } [ ] = / ‘ \ < > ~ * United States Belgium Brazil...
  • Page 41 Keyboard Country (continued) Italy Latin America Netherlands (Dutch) Norway Poland Portugal Romania Russia Slovakia Spain Sweden Switzerland (German) 2 - 11...
  • Page 42: Keyboard Style

    Keyboard Country (continued) Turkey F Turkey Q U.K. Please refer to the Honeywell website (www.honeywell.com/aidc) for complete keyboard country support information and applicable interfaces. If you need to program a keyboard for a country other than one listed above, scan the Pro- gram Keyboard Country barcode below, then scan the numeric barcode(s) for the appropriate country from the inside back cover, then the Save barcode.
  • Page 43: Keyboard Modifiers

    Shift Lock is used when you normally have the Shift Lock key on (not common to U.S. keyboards). Shift Lock Automatic Caps Lock is used if you change the Caps Lock key on and off. The software tracks and reflects if you have Caps Lock on or off (AT and PS/2 only).
  • Page 44 support all keyboard country codes. New users should use the Windows mode. Refer to Keyboard Function Relationships, page 10-1 for CTRL+ ASCII Values. Default = Control + ASCII Mode Off Windows Mode Control + ASCII Mode On * Control + ASCII Mode Off DOS Mode Control + ASCII Mode Turbo Mode: The image scanner sends characters to a terminal faster.
  • Page 45 Automatic Direct Connect Mode: This selection can be used if you have an IBM AT style terminal and the system is dropping characters. Default = Off Automatic Direct Connect Mode On * Automatic Direct Connect Mode Off 2 - 15...
  • Page 46: Rs-232 Baud Rate

    RS-232 Baud Rate Baud Rate sends the data from the image scanner to the terminal at the speci- fied rate. The host terminal must be set for the same baud rate as the image scanner. Default = 115,200. 1200 2400 4800 9600 19200...
  • Page 47: Rs-232 Receiver Time-Out

    Parity provides a means of checking character bit patterns for validity. Default = None. 7 Data, 1 Stop, Parity Even 7 Data, 1 Stop, Parity None 7 Data, 1 Stop, Parity Odd 7 Data, 2 Stop, Parity Even 7 Data, 2 Stop Parity None 7 Data, 2 Stop, Parity Odd 8 Data, 1 Stop, Parity Even * 8 Data, 1 Stop, Parity None...
  • Page 48: Rs-232 Handshaking

    RS-232 Handshaking RS-232 Handshaking allows control of data transmission from the image scan- ner using software commands from the host device. CTS/RTS operates in mode 2. When this feature is turned Off, no data flow control is used. When Data Flow Control is turned On, the host device suspends transmission by sending the XOFF character (DC3, hex 13) to the image scanner.
  • Page 49 Escape commands are addressed to the image scanner via “Application Work Groups.” Once a command is sent, all image scanners in a group respond to that command. Because of this situation, it is recommended that each image scanner is assigned to its own group in Host ACK mode. The commands to which the image scanner responds are listed on page 2-21.
  • Page 50: Host Ack Enable

    Host ACK Enable Host ACK On * Host ACK Off 2 - 20...
  • Page 51: Wand Emulation

    2020 Host Escape Commands Command Action a Double beeps to indicate a successful menu change was made. b Triple beeps to indicate a menu change was unsuccessful. 1 The green LED illuminates for 135 milliseconds followed by a pause.
  • Page 52: Wand Emulation Data Block Size

    The Code 39 Format barcode below sets the terminal ID to 61, and the Same Code Format barcode sets the terminal ID to 64. Default = Code 39 Format. * Code 39 Format Same Code Format Wand Emulation Data Block Size This transmits the data in smaller blocks to prevent buffer overflow.
  • Page 53: Wand Emulation Delay Between Blocks

    Wand Emulation Delay Between Blocks This sets the delay time between data blocks. Default = 50ms. * 50ms 150ms 500ms Wand Emulation Overall Checksum When this option is turned on, a computed check character is added at the end of the entire message. The check character is the character which when Exclu- sive-OR’d with every preceding character of the message yields a result of 0x00 (00H).
  • Page 54: Wand Emulation Transmission Rate

    Wand Emulation Transmission Rate The Transmission Rate is limited by the terminal’s ability to receive data without dropping characters. Default = 25 inches/second. * 25 Wand Emulation Polarity The Polarity can be sent as standard with black bars high, or reversed with white spaces high.
  • Page 55: Wand Emulation Idle

    Wand Emulation Idle The idle describes the state of the image scanner when no data is being trans- mitted. When in Wand Emulation mode, you must set the image scanner’s idle state to match the idle state for the device to which the image scanner is con- nected.
  • Page 56 2 - 26...
  • Page 57: Chapter 3 - Basic System Operation

    Basic System Operation Cordless Base The cordless base provides the link between the cordless image scanner and the host system. The base contains an interface assembly and an RF commu- nication module. The RF communication module performs the data exchange between the cordless image scanner and the interface assembly.
  • Page 58: System Conditions

    System Conditions The components of the cordless system interact in specific ways as you associ- ate an image scanner to a base, as you move an image scanner out of range, bring an image scanner back in range, or swap image scanners between two cordless systems.
  • Page 59: Base Charge Mode

    Base Charge Mode In order for the battery to be charged, there must be enough voltage for the cir- cuitry to work. There are three methods during which power can be supplied to the base: 1:9VDC power supply connected to the barrel connector 2:12VDC host power source only 3:5VDC host power source only The chart below describes each selection by condition.
  • Page 60: Beeper And Led Sequences And Meaning

    Beeper and LED Sequences and Meaning The image scanner contains LEDs on the top of the unit to indicate its power up, communication, and battery status. Simply stated, red LED = error; green LED = success of any type. The unit’s audible indicators have meaning as well: 3 beeps = error;...
  • Page 61: Image Scanner Modes

    The table below list the indication and cause of the LED illumination and beeps for the 2020. System Condition System Status Indicator (Red LED) Power On/System Idle LED is on Receiving Data (2020 only) Blink LED for short duration in multiple pulses. Occurs while transferring data to/from the RF module or the Host port.
  • Page 62: Locked Link Mode - Single Image Scanner

    Locked Link Mode - Single Image Scanner If you link an image scanner to a base using the Locked Link Mode, other image scanners are blocked from being linked if they are inadvertently placed into the base. If you do place a different image scanner into the base, it will charge the image scanner, but the image scanner will not be linked.
  • Page 63: Multiple Image Scanner Operation

    Multiple Image Scanner Operation Note: Multiple Image Scanner Operation Mode allows you to link up to 7 image scanners to one base. You cannot join an 8th image scanner until you unlink one of the 7 image scanners or take an image scanner out of range.
  • Page 64 To rename image scanners with sequential, numeric names, scan the barcodes below. Scan the Reset code after each name change and wait for the scanner to re-link to the base before scanning another barcode to rename the next image scanner. 0001 0002 0003...
  • Page 65: Image Scanner Report

    You may use Barcode Builder, which is included with QuickView. Refer to QuickView on page 11-6 for instructions about downloading QuickView from the Honeywell website: www.honeywell.com/aidc Image Scanner Report Scan the barcode below to generate a report for the connected image scanners.
  • Page 66: Application Work Group Selection

    Application Work Group Selection This programming selection allows you to assign an image scanner to a work group by scanning the barcode below. You may then program the settings (e.g., beeper volume, prefix/suffix, data formatter) that your application requires. Default = Group 0. * Group 0 Group 1 Group 2...
  • Page 67: Resetting The Standard Product Default Settings: All Application Work Groups

    Resetting the Standard Product Default Settings: All Application Work Groups The following barcode defaults all of the work groups to the factory settings. Standard Product Default Settings: All Application Groups Menu Commands, beginning on page 12-5 list the standard product default settings for each of the commands (indicated by an asterisk (*) on the program- ming pages).
  • Page 68: Using The Image Scanner With Bluetooth Devices

    Non-Base BT Connection PDA/Mobility Systems Devices You may also use the image scanner with a PDA or a Honeywell Mobility Sys- tems device. Scan the barcode below and follow the instructions supplied with your Bluetooth device to locate the imager, and connect with it.
  • Page 69 2. Tap the Start flag at the top left of the Today screen. 3. Select Settings at the bottom of the menu. 3 - 13...
  • Page 70 4. Tap the Connections tab at the bottom of the screen and then tap the Radio Manager icon. 5. Enable one of the Bluetooth modes (e.g., Bluetooth only or 80211b/ Bluetooth). The screen below shows that only the GSM radio is active. 3 - 14...
  • Page 71 6. Tap Bluetooth Only and Apply. The status changes to Success. 7. Tap OK in the top right of the screen and tap X on the upper, right corner to return to the Today screen. The Bluetooth icon displays in the bottom, right part of the screen.
  • Page 72 9. Select Advanced Features -> Bluetooth Devices. Note: If you have already used Bluetooth and changed any of the default settings, you may want to first select My Bluetooth device and ensure that it is connectable and the Bluetooth com port is enabled. 10.
  • Page 73 11. Tap Next on the Bluetooth Device Discovery Wizard. 12. Keep the default radio button selection of Any Bluetooth device and select Next. The Mobility Systems device searches for other Bluetooth devices. If the 4820i is in BTConnection - PDA Mobility Systems Mode (see Connection - PDA/Mobility Systems Device on page 3-12), it will appear in the device discovery window.
  • Page 74: Changing The Image Scanner's Bluetooth Pin Code

    13. Select the 4820i by checking the box and select Next and Finish. 14. Select Next and Finish. 15. Select the X to return to the desktop. Changing the Image Scanner’s Bluetooth PIN Code Some devices require a PIN code as part of the Bluetooth security features. Your image scanner’s default PIN is 1234, which you may need to enter the first time you connect to your PDA or PC.
  • Page 75 characters. To change the PIN, scan the barcode below and then scan the appropriate numeric barcodes from the Programming Chart inside the back cover of this manual. Scan Save to save your selection. Bluetooth PIN When authentication is enabled on the Mobility Systems device, you must enter the PIN of the image scanner.
  • Page 76: Starting Scanwedge

    Once the image scanner is linked to the Mobility Systems device, you need to configure ScanWedge for the correct COM port and then start ScanWedge. For additional information, refer to the Honeywell Powertools User’s Guide, which can be downloaded from www.honeywell.com/aidc.
  • Page 77: Alarm Sound Type

    and then set the time-out duration (from 0-3000 seconds) by scanning digits on Programming Chart inside the back cover, then scanning Save. Default = 0 sec (no alarm). Base Alarm Duration Image Scanner Alarm Duration Note: If you are out of range when you scan a barcode, you will receive an error beep even if you do not have the alarm set.
  • Page 78: Data Accumulation Mode

    Data Accumulation Mode Note: Data Accumulation mode has limitations when using multiple scanners to one base. If a cordless system is being used in "multiple link mode" where up to 7 scanners are to be connected to one base, some accumulated or batched scans could be lost if scanners are constantly being moved in and out of range.
  • Page 79: Batch Mode Transmit Delay

    Batch Mode Transmit Delay Sometimes when accumulated scans are sent to the host system, the transmis- sion of those scans is too fast for the application to process. To program a transmit delay between accumulated scans, scan one of the following delays. Default = Off.
  • Page 80 3 - 24...
  • Page 81: Chapter 4 - Output

    Output Good Read Indicators Beeper – Good Read The beeper may be programmed On or Off in response to a good read. Turning this option off, only turns off the beeper response to a good read indication. All error and menu beeps are still audible. Default = On. * Beeper - Good Read On Beeper - Good Read Off Beeper Volume –...
  • Page 82: Beeper Pitch - Good Read

    Beeper Pitch – Good Read The beeper pitch codes modify the pitch (frequency) of the beep the image scanner emits on a good read. Default = Medium. Low (1600 Hz) * Medium (3250 Hz) High (4200 Hz) Beeper Duration – Good Read The beeper duration codes modify the length of the beep the image scanner emits on a good read.
  • Page 83: Good Read Delay

    scan the barcode below and then scan a digit (1-9) barcode and the Save barcode on the Programming Chart inside the back cover of this manual. Default = 1. Number of Beeps/LED Flashes Good Read Delay This sets the minimum amount of time before the image scanner can read another barcode.
  • Page 84: Serial Trigger Modes

    Serial Trigger Modes Manual/Serial Trigger, Low Power You can activate the image scanner either by pressing the trigger, or using a serial trigger command (see Trigger Commands on page 12-4). When in manual trigger mode, the image scanner scans until a barcode is read, or until the trigger is released.
  • Page 85 If there are no trigger pulls during the timer interval, the image scanner goes into power down mode. Whenever the trigger is enabled, the timer is reset. If the image scanner is placed in the 2020 cradle and the battery is in the process of being charged, the image scanner will not go into power down mode.
  • Page 86: Scan Stand Mode

    Scan Stand Mode When a unit is in Scan Stand mode, it remains idle as long as it sees the Scan Stand symbol, below. When a different code is presented, the image scanner is triggered to read the new code. Note: The image scanner automatically adjusts the illumination LEDs to the lowest light level possible to maintain a good lock on the Scan Stand symbol.
  • Page 87: Presentation Mode

    Presentation Mode Scanning the barcode below programs the image scanner to work in Presentation Mode. Presentation Mode uses ambient light to detect barcodes. The LEDs are off until a barcode is presented to the image scanner, then the LEDs turn on automatically to read the code. If the light level in the room is not high enough, Presentation Mode may not work properly.
  • Page 88: Presentation Sensitivity

    Presentation Sensitivity Presentation Sensitivity is a numeric range that increases or decreases the image scanner's reaction time to barcode presentation. To set the sensitivity, scan the Sensitivity barcode, then scan the degree of sensitivity (from 0-20) from the inside back cover, and Save. 0 is the most sensitive setting, and 20 is the least sensitive.
  • Page 89: Image Snap And Ship

    Image Snap and Ship Image Snap and Ship tells the imager to take a picture (rather than read a barcode) when the trigger is pressed. Once the picture is snapped, it is shipped to the host system as a jpeg file by default. To revert to barcode reading, you must change to a different trigger mode (see Serial Trigger Modes beginning on...
  • Page 90: User-Specified Reread Delay

    Use shorter delays in applications where repetitive barcode scanning is required. Reread Delay only works when in Presentation Mode (see page 4-7). Default = Medium. Short (500 ms) * Medium (750 ms) Long (1000 ms) Extra Long (2000 ms) Extra Long (2000 ms) User-Specified Reread Delay If you want to set your own length for the reread delay, scan the barcode below, then set the delay (from 0-30,000 milliseconds) by scanning digits from the...
  • Page 91: Illumination Lights

    If you have an aimer delay programmed (see Aimer Delay on page 4-12), the aimer will be at 100% power during the delay, regardless of the LED Power Level. Note: If you scan the Off barcode, both the aimer and illumination lights turn off, making it impossible to scan barcodes in low light.
  • Page 92: Aimer Delay

    Aimer Delay The aimer delay allows a delay time for the operator to aim the image scanner before the picture is taken. Use these codes to set the time between when the trigger is pulled and when the picture is taken. During the delay time, the aiming light will appear, but the LEDs won’t turn on until the delay time is over.
  • Page 93: Centering

    Centering Use Centering to narrow the image scanner’s field of view to make sure the image scanner reads only those barcodes intended by the user. For instance, if multiple codes are placed closely together, centering will insure that only the desired codes are read.
  • Page 94: Decode Search Mode

    Scan Centering On, then scan one of the following barcodes to change the top, bottom, left, or right of the centering window. Then scan the percent you want to shift the centering window using digits on the inside back cover of this manual.
  • Page 95: Preferred Symbology

    Quick Omnidirectional - This is an abbreviated search for barcode features around the center region of an image. This mode quickly reads all symbologies in any orientation. The Quick Omnidirectional mode may miss some off-center symbols, as well as larger Data Matrix and QR Code symbols. Quick Omnidirectional Preferred Symbology Note: This selection does not apply to OCR.
  • Page 96 High Priority Symbology To specify the high priority symbology, scan the High Priority Symbology bar code below. On the Symbology Chart on page A-1, find the symbology you want to set as high priority. Locate the Hex value for that symbology and scan the 2 digit hex value from the Programming Chart (inside back cover).
  • Page 97: Output Sequence Overview

    Output Sequence Overview Require Output Sequence When turned off, the barcode data will be output to the host as the image scanner decodes it. When turned on, all output data must conform to an edited sequence or the image scanner will not transmit the output data to the host device.
  • Page 98 • Discard This exits without saving any Output Sequence changes. Output Sequence Example In this example, you are scanning Code 93, Code 128, and Code 39 barcodes, but you want the image scanner to output Code 39 1st, Code 128 2nd, and Code 93 3rd, as shown below.
  • Page 99: Output Sequence Editor

    To program the previous example using specific lengths, you would have to count any programmed prefixes, suffixes, or formatted characters as part of the length. If you use the example on page 4-18, but assume a suffix and specific code lengths, you would use the following command line: SEQBLK62001241FF6A001342FF69001243FF The breakdown of the command line is shown below: SEQBLK sequence editor start command...
  • Page 100: Multiple Symbols

    When the output sequence is Off , the barcode data is output to the host as the image scanner decodes it. Default = Off. Note: This selection is unavailable when the Multiple Symbols Selection is turned on. Required On/Not Required *Off Multiple Symbols When this programming selection is turned On, it allows you to read multiple...
  • Page 101: No Read

    No Read With No Read turned On, the image scanner notifies you if a code cannot be read. If using a QuickView Scan Data Window, an “NR” appears when a code cannot be read. If No Read is turned Off, the “NR” will not appear. Default = Off.
  • Page 102: Video Reverse

    Video Reverse Video Reverse is used to allow the image scanner to read barcodes that are inverted. The Off barcode below is an example of this type of barcode. If additional menuing is required, Video Reverse must be disabled to read the menu barcodes and then re-enabled after menuing is completed.
  • Page 103 * Upright Rotate Code Clockwise 90° (Rotate Image Scanner Counterclockwise) Upside Down Rotate Code Counterclockwise 90° (Rotate Image Scanner Clockwise) 4 - 23...
  • Page 104 4 - 24...
  • Page 105: Chapter 5 - Data Editing

    Data Editing Prefix/Suffix Overview When a barcode is scanned, additional information is sent to the host computer along with the barcode data. This group of barcode data and additional, user-defined data is called a “message string.” The selections in this section are used to build the user-defined data into the message string.
  • Page 106: To Clear One Or All Prefixes Or Suffixes

    which you want to apply the prefix or suffix. For example, for Code 128, Code ID is “j” and Hex ID is “6A”. Step 3. Scan the 2 hex digits from the Programming Chart inside the back cover of this manual or scan 9, 9 for all symbologies. Step 4.
  • Page 107: To Add A Carriage Return Suffix To All Symbologies

    Step 1. Scan the Clear One Prefix or Clear One Suffix symbol. Step 2. Determine the 2 digit Hex value from the Symbology Chart (included in Symbology Chart, beginning on page A-1) for the symbology from which you want to clear the prefix or suffix. Step 3.
  • Page 108: Prefix Selections

    Prefix Selections Add Prefix Clear One Prefix Clear All Prefixes Suffix Selections Add Suffix Clear One Suffix Clear All Suffixes Function Code Transmit When this selection is enabled and function codes are contained within the scanned data, the image scanner transmits the function code to the terminal. Charts of these function codes are provided in Supported Interface Keys start-...
  • Page 109: Intercharacter, Interfunction, And Intermessage Delays

    Intercharacter, Interfunction, and Intermessage Delays Some terminals drop information (characters) if data comes through too quickly. Intercharacter, interfunction, and intermessage delays slow the transmission of data, increasing data integrity. Each delay is composed of a 5 millisecond step. You can program up to 99 steps (of 5 ms each) for a range of 0-495 ms.
  • Page 110: Interfunction Delay

    Next, scan the Character to Trigger Delay barcode, then the 2-digit hex value for the ASCII character that will trigger the delay Code Page Mapping of Printed Barcodes on page A-7. Delay Length Character to Trigger Delay To remove this delay, scan the Delay Length barcode, and set the number of steps to 0.
  • Page 111: Intermessage Delay

    Intermessage Delay An intermessage delay of up to 495 milliseconds may be placed between each scan transmission. Scan the Intermessage Delay barcode below, then scan the number of milliseconds and the Save barcode using the Programming Chart inside the back cover of this manual. 1st Scan Transmission 2nd Scan Transmission Intermessage Delay...
  • Page 112 5 - 8...
  • Page 113: Chapter 6 - Data Formatting

    Data Formatting Data Format Editor Introduction You may use the Data Format Editor to change the image scanner’s output. For example, you can use the Data Format Editor to insert characters at certain points in barcode data as it is scanned. The selections in the following pages are used only if you wish to alter the output.
  • Page 114: Other Programming Selections

    Step 4. Code I.D. In the Symbology Chart, beginning on page A-1, find the symbology to which you want to apply the data format. Locate the Hex value for that symbology and scan the 2 digit hex value from the Programming Chart inside the back cover of this manual.
  • Page 115 F4 Send “xx” character “nn” times (Insert) leaving cursor in current cursor posi- tion. Syntax = F4xxnn (xx stands for the hex value for an ASCII code, see Code Page Mapping of Printed Barcodes on page A-7, and nn is the numeric value (00-99) for the number of times it should be sent.) E9 Send all but the last “nn”...
  • Page 116 ters to be replaced and xx defines replacement characters, continuing through zz and zz E5 Terminates character replacement. Syntax = E5. FE Compare character in current cursor position to the character “xx.” If char- acters are equal, increment cursor. If characters are not equal, no format match.
  • Page 117: Data Format Editor

    Data Format Editor Enter Data Format * Default Data Format Clear One Data Format Clear All Data Formats Save Discard Data Formatter When Data Formatter is turned off, the barcode data is output to the host as read (including prefixes and suffixes). Choose one of the following options. Default = Data Formatter On, but Not Required.
  • Page 118: Alternate Data Formats

    Alternate Data Formats Alternate formats allow you “single shot” capability to scan one barcode using a different data format than your primary format. When data formats are pro- grammed (see page 6-1), you must input whether you are programming the pri- mary format, or an alternate format numbered 1, 2, or 3.
  • Page 119 Symbologies This programming section contains the following menu selections. Refer to Chapter 12 for settings and defaults. • All Symbologies • ID-tag (UPU 4-State) • Australian Post • Intelligent Mail Barcode • Aztec Code • Interleaved 2 of 5 • British Post •...
  • Page 120: All Symbologies

    All Symbologies If you want to decode all the symbologies allowable for your image scanner, scan the All Symbologies On code. If on the other hand, you want to decode only a particular symbology, scan All Symbologies Off followed by the On sym- bol for that particular symbology.
  • Page 121: Codabar

    Codabar Codabar * On Codabar Start/Stop Characters Start/Stop characters identify the leading and trailing ends of the barcode. You may either transmit, or not transmit Start/Stop characters. Default = Don’t Transmit . Transmit * Don’t Transmit Codabar Check Character Codabar check characters are created using different “modulos.”...
  • Page 122: Codabar Concatenation

    When Check Character is set to Validate, but Don’t Transmit , the unit will only read Codabar barcodes printed with a check character, but will not transmit the check character with the scanned data. * No Check Character Validate Modulo 16, but Don’t Transmit Validate Modulo 16 and Transmit...
  • Page 123: Code 39

    Codabar Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 2-60. Minimum Default = 4, Maximum Default = 60. Minimum Message Length Maximum Message Length Code 39 <...
  • Page 124 Code 39 Check Character No Check Character indicates that the image scanner reads and transmits barcode data with or without a check character. When Check Character is set to Validate, but Don’t Transmit, the unit only reads Code 39 barcodes printed with a check character, but will not transmit the check character with the scanned data.
  • Page 125: Code 32 Pharmaceutical (Paraf)

    the barcodes are read, deleting the first space from each. The image scanner transmits the appended data when it reads a Code 39 barcode that starts with a character other than a space. Default = Off. * Off Code 32 Pharmaceutical (PARAF) Code 32 Pharmaceutical is a form of the Code 39 symbology used by Italian pharmacies.
  • Page 126: Full Ascii

    Full ASCII If Full ASCII Code 39 decoding is enabled, certain character pairs within the barcode symbol will be interpreted as a single character. For example: $V will be decoded as the ASCII character SYN, and /C will be decoded as the ASCII character #.
  • Page 127: Interleaved 2 Of 5

    Page Mapping of Printed Barcodes on page A-7), and scan the value and the Save barcode from the Programming Chart on the inside the back cover of this manual. The data characters should then appear properly. Code 39 Code Page Interleaved 2 of 5 <...
  • Page 128 When Check Digit is set to Validate and Transmit, the image scanner only reads Interleaved 2 of 5 barcodes printed with a check digit, and will transmit this digit at the end of the scanned data. Default = No Check Digit. * No Check Digit Validate, but Don’t Transmit Validate and Transmit...
  • Page 129: Code 93 Code Page

    Code 93 < Default All Code 93 Settings > Code 93 * On Code 93 Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 0-80. Minimum Default = 0, Maximum Default = 80. Minimum Message Length Maximum Message Length Code 93 Code Page...
  • Page 130: Straight 2 Of 5 Industrial (Three-Bar Start/Stop)

    Mapping of Printed Barcodes on page A-7), and scan the value and the Save barcode from the Programming Chart on the inside the back cover of this man- ual. The data characters should then appear properly. Code 93 Code Page Straight 2 of 5 Industrial (three-bar start/stop) ...
  • Page 131: Straight 2 Of 5 Iata (Two-Bar Start/Stop)

    Straight 2 of 5 IATA (two-bar start/stop) Straight 2 of 5 IATA * Off Straight 2 of 5 IATA Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 7-2) for additional information.
  • Page 132: Matrix 2 Of 5

    Matrix 2 of 5 Matrix 2 of 5 * Off Matrix 2 of 5 Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-80.
  • Page 133: Code 11

    Code 11 Code 11 * Off Check Digits Required This option sets whether 1 or 2 check digits are required with Code 11 bar- codes. Default = Two Check Digits. One Check Digit * Two Check Digits Code 11 Message Length Scan the barcodes below to change the message length.
  • Page 134: Isbt 128 Concatenation

    Code 128 Code 128 * On ISBT 128 Concatenation In 1994 the International Society of Blood Transfusion (ISBT) ratified a standard for communicating critical blood information in a uniform manner. The use of ISBT formats requires a paid license. The ISBT 128 Application Specification describes 1) the critical data elements for labeling blood products, 2) the current recommendation to use Code 128 due to its high degree of security and its space-efficient design, 3) a variation of Code 128 that supports concatenation...
  • Page 135: Code 128 Code Page

    Code 128 Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 0-80. Minimum Default = 0, Maximum Default = 80. Minimum Message Length Maximum Message Length Code 128 Code Page Code pages define the mapping of character codes to characters.
  • Page 136: Upc-A

    Telepen * Off Telepen Output Using AIM Telepen Output, the image scanner reads symbols with start/stop pattern 1 and decodes them as standard full ASCII (start/stop pattern 1). When Original Telepen Output is selected, the image scanner reads symbols with start/stop pattern 1 and decodes them as compressed numeric with optional full ASCII (start/stop pattern 2).
  • Page 137 UPC-A * On UPC-A Check Digit This selection allows you to specify whether the check digit should be transmit- ted at the end of the scanned data or not. Default = On . * On UPC-A Number System The numeric system digit of a UPC symbol is normally transmitted at the begin- ning of the scanned data, but the unit can be programmed so it will not transmit it.
  • Page 138 UPC-A Addenda This selection adds 2 or 5 digits to the end of all scanned UPC-A data. Default = Off for both 2 Digit and 5 Digit Addenda. 2 Digit Addenda On * 2 Digit Addenda Off 5 Digit Addenda On * 5 Digit Addenda Off UPC-A Addenda Required When Required is scanned, the image scanner will only read UPC-A barcodes...
  • Page 139: Upc-A/Ean-13

    UPC-A/EAN-13 with Extended Coupon Code Use the following codes to enable or disable UPC-A and EAN-13 with Extended Coupon Code. When left on the default setting (Off), the imager treats Coupon Codes and Extended Coupon Codes as single barcodes. If you scan the Allow Concatenation code, when the imager sees the coupon code and the extended coupon code in a single scan, it transmits both as sepa- rate symbologies.
  • Page 140 UPC-E0 Expand UPC-E Expand expands the UPC-E code to the 12 digit, UPC-A format. Default = Off. * Off UPC-E0 Addenda Required When Required is scanned, the image scanner will only read UPC-E barcodes that have addenda. Default = Not Required. Required * Not Required UPC-E0 Addenda Separator...
  • Page 141 UPC-E0 Check Digit Check Digit specifies whether the check digit should be transmitted at the end of the scanned data or not. Default = On. * On UPC-E0 Number System The numeric system digit of a UPC symbol is normally transmitted at the begin- ning of the scanned data, but the unit can be programmed so it will not transmit it.
  • Page 142: Upc-E1

    UPC-E1 Most UPC barcodes lead with the 0 number system. For these codes, use UPC-E0 (page 7-21). If you need to read codes that lead with the 1 number system, use the UPC-E1 On selection. Default = Off. UPC-E1 On * UPC-E1 Off EAN/JAN-13 ...
  • Page 143 EAN/JAN-13 Addenda This selection adds 2 or 5 digits to the end of all scanned EAN/JAN-13 data. Default = Off for both 2 Digit and 5 Digit Addenda. 2 Digit Addenda On * 2 Digit Addenda Off 5 Digit Addenda On * 5 Digit Addenda Off EAN/JAN-13 Addenda Required When Required is scanned, the image scanner will only read EAN/JAN-13 bar-...
  • Page 144: Isbn Translate

    ISBN Translate When On is scanned, EAN-13 Bookland symbols are translated into their equiv- alent ISBN number format. Default = Off. * Off EAN/JAN-8 EAN/JAN-8 * On EAN/JAN-8 Check Digit This selection allows you to specify whether the check digit should be transmit- ted at the end of the scanned data or not.
  • Page 145 EAN/JAN-8 Addenda This selection adds 2 or 5 digits to the end of all scanned EAN/JAN-8 data. Default = Off for both 2 Digit and 5 Digit Addenda. 2 Digit Addenda On * 2 Digit Addenda Off 5 Digit Addenda On * 5 Digit Addenda Off EAN/JAN-8 Addenda Required When Required is scanned, the image scanner will only read EAN/JAN-8 bar-...
  • Page 146: Msi

    * Off MSI Check Character Different types of check characters are used with MSI barcodes. You can program the image scanner to read MSI barcodes with Type 10 check characters. Default = Validate Type 10, but Don’t Transmit. When Check Character is set to Validate Type 10 and Transmit, the image scanner will only read MSI barcodes printed with the specified type check character, and will transmit this character at the end of the scanned data.
  • Page 147: Plessey Code

    MSI Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 4-48. Minimum Default = 4, Maximum Default = 48. Minimum Message Length Maximum Message Length Plessey Code ...
  • Page 148: Gs1 Databar Omnidirectional

    GS1 DataBar Omnidirectional < Default All GS1 DataBar Omnidirectional Settings > GS1 DataBar Omnidirectional * On GS1 DataBar Limited < Default All GS1 DataBar Limited Settings > GS1 DataBar Limited * On GS1 DataBar Expanded < Default All GS1 DataBar Expanded Settings > 7 - 30...
  • Page 149: Posicode

    GS1 DataBar Expanded * On GS1 DataBar Expanded Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 4-74. Minimum Default = 4, Maximum Default = 74. Minimum Message Length Maximum Message Length PosiCode...
  • Page 150: Posicode A And B

    PosiCode A and B * On You have to have PosiCode A and B on to read any of the PosiCode symbolo- gies. A and B On (No Limited) A and B and Limited A On (Limited B Off) * A and B and Limited B On (Limited A Off) PosiCode Message Length Scan the barcodes below to change the message length.
  • Page 151: Codablock F

    Trioptic Code is used for labeling magnetic storage media. * Off Codablock F Codablock F * Off Codablock F Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 7-2) for additional information.
  • Page 152: Code 16K

    Code 16K Code 16K * Off Code 16K Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 0-160. Minimum Default = 1, Maximum Default = 160. Minimum Message Length Maximum Message Length Code 49...
  • Page 153 Code 49 * On Code 49 Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-81. Minimum Default = 1, Maximum Default = 81. Minimum Message Length Maximum Message Length 7 - 35...
  • Page 154: Pdf417

    PDF417 < Default All PDF417 Settings > PDF417 * On PDF417 Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-2750. Minimum Default = 1, Maximum Default = 2750. Minimum Message Length Maximum Message Length MicroPDF417...
  • Page 155: Gs1 Composite Codes

    MicroPDF417 * Off MicroPDF417 Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-366. Minimum Default = 1, Maximum Default = 366. Minimum Message Length Maximum Message Length GS1 Composite Codes Linear codes are combined with a unique 2D composite component to form a...
  • Page 156: Upc/Ean Version

    UPC/EAN Version Scan the UPC/EAN Version On barcode to decode GS1 Composite symbols that have a UPC or EAN linear component. (This does not affect GS1 Compos- ite symbols with a GS1-128 or GS1 linear component.) UPC/EAN Version On * UPC/EAN Version Off GS1 Composite Code Message Length Scan the barcodes below to change the message length.
  • Page 157: Tcif Linked Code 39 (Tlc39)

    Default = GS1 Emulation Off . GS1-128 Emulation GS1 DataBar Emulation GS1 Code Expansion Off * GS1 Emulation Off TCIF Linked Code 39 (TLC39) This code is a composite code since it has a Code 39 linear component and a MicroPDF417 stacked code component.
  • Page 158: Id-Tag (Upu 4-State)

    ID-tag (UPU 4-State) * Off Postnet * Off Postnet Check Digit This selection allows you to specify whether the check digit should be transmit- ted at the end of the scanned data. Default = Don’t Transmit. Transmit Check Digit * Don’t Transmit Check Digit 7 - 40...
  • Page 159: Planet Code

    Planet Code * Off Planet Code Check Digit This selection allows you to specify whether the check digit should be transmit- ted at the end of the scanned data. Default = Don’t Transmit. Transmit Check Digit * Don’t Transmit Check Digit 7 - 41...
  • Page 160: British Post

    British Post * Off Canadian Post * Off Kix (Netherlands) Post Note: Kix code can misread when scanned sideways or upside down. Use Working Orientation, page 4-22, if your Kix codes will not usually be presented upright to the image scanner. * Off Australian Post * Off...
  • Page 161 Numeric N Table causes that field to be interpreted as numeric data using the N Table. Alphanumeric C Table causes the field to be interpreted as alphanumeric data using the C Table. Refer to the Australian Post Specification Tables. Default = Bar Output. * Bar Output Numeric N Table Alphanumeric C Table...
  • Page 162: Japanese Post

    Japanese Post * Off China Post China Post * Off China Post Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 2-80.
  • Page 163: Korea Post

    Korea Post Korea Post * Off Korea Post Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maxi- mum lengths = 2-80. Minimum Default = 4, Maximum Default = 48. Minimum Message Length Maximum Message Length 7 - 45...
  • Page 164: Qr Code

    QR Code < Default All QR Code Settings > QR Code This selection applies to both QR Code and Micro QR Code. * On QR Code Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 7-2) for additional information.
  • Page 165: Data Matrix

    Data Matrix < Default All Data Matrix Settings > Data Matrix * On Data Matrix Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-3116. Minimum Default = 1, Maximum Default = 3116. Minimum Message Length Maximum Message Length 7 - 47...
  • Page 166: Maxicode

    MaxiCode < Default All MaxiCode Settings > MaxiCode * On MaxiCode Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-150. Minimum Default = 1, Maximum Default = 150. Minimum Message Length Maximum Message Length 7 - 48...
  • Page 167: Aztec Code

    Aztec Code < Default All Aztec Code Settings > Aztec Code * On Aztec Code Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-3832. Minimum Default = 1, Maximum Default = 3832. Minimum Message Length Maximum Message Length Aztec Runes...
  • Page 168: Chinese Sensible (Han Xin) Code

    Chinese Sensible (Han Xin) Code < Default All Han Xin Settings > Han Xin Code * Off Han Xin Code Message Length Scan the barcodes below to change the message length. Refer to Message Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 1-7833.
  • Page 169: Chapter 8 - Imaging Commands

    Imaging Commands The image scanner is like a digital camera in the way it captures, manipulates, and transfers images. The following commands allow you to alter the way the imager performs these functions. Single-Use Basis Imaging Commands with their modifiers send instructions to the imager on a single-use basis, and take effect for a single image capture.
  • Page 170: Image Snap - Imgsnp

    Step 1 - Take a Picture Using IMGSNP Image Snap - IMGSNP An image is taken whenever the hardware button is pressed, or when the Image Snap (IMGSNP) command is processed. The image snap command has many different modifiers that can be used to change the look of the image in memory.
  • Page 171 L - LED State Determines if the LEDs should be on or off, and when. Ambient illumination (0L) is preferred for taking pictures of color documents, such as ID cards, especially when the imager is in a stand. LED illumination (1L) is preferred when the imager is handheld.
  • Page 172 G - Gain Gain is used in Manual Style only (2P). Like a volume control, the gain modifier boosts the signal and multiplies the pixel value. As you increase the gain, the noise in an image is also amplified. No gain (default) Medium gain Heavy gain Maximum gain...
  • Page 173: Image Ship - Imgshp

    % - Target Set Point Percentage Sets the target point for the light and dark values in the captured image. A setting of 75% means 75% of the pixels are at or below the target white value, and 25% of the pixels are above the target white value. Altering this setting from the default is not recommended under normal circumstances.
  • Page 174: Imgshp Modifiers

    IMGSHP Modifiers A - Infinity Filter Enhances pictures taken from very long distances (greater than 10 feet or 3m). The Infinity Filter should not be used with IMGSHP Modifiers (page 8-6). Infinity filter off (default) Infinity filter on Example of Infinity Filter off (0A) Example of Infinity Filter on (1A) from approximately 12 feet from approximately 12 feet (3.66m)
  • Page 175 E - Edge Sharpen An edge sharpen filter cleans up the edges of an image, making it look cleaner and sharper. While edge sharpening does make the image look cleaner, it also removes some fine detail from the original image. The strength of the edge sharpen filter can be entered from 1 to 24.
  • Page 176 H - Histogram Stretch Increases the contrast of the transmitted image. Not available with some image formats. No stretch (default) Histogram stretch Example of Histogram Stretch at 0H: Example of Histogram Stretch at 1H: I - Invert Image Invert image is used to rotate the image around the X or Y axis. Invert around the X axis (flips picture upside down) Invert around the Y axis (flips picture left to right) Example of image not...
  • Page 177 IF- Noise Reduction Used to reduce the salt and pepper noise in an image. No salt and pepper noise reduction (default) Salt and pepper noise reduction Example of Noise Reduction Off Example of Noise Reduction On (0if): (1if): 8 - 9...
  • Page 178 IR - Image Rotate Image as snapped (rightside up) (default) Rotate image 90 degrees to the right Rotate image 180 degrees (upside down) Rotate image 90 degrees to the left Example of Image Rotate set to Example of Image Rotate set to 2ir: 0ir: Example of Image Rotate set to...
  • Page 179 K - Gamma Correction Gamma measures the brightness of midtone values produced by the image. You can brighten or darken an image using gamma correction. A higher gamma correction yields an overall brighter image. The lower the setting, the darker the image. The optimal setting for text images is 50K. Gamma correction off (default) Apply gamma correction for brightening typical document image Apply gamma correction factor n ( n = 0-1,000)
  • Page 180 The bottom edge of the shipped image corresponds to row n - 1 of the image in memory. Range: 000 - 480. (Default = all rows) Uncropped Image: Example of Image Example of Image Crop set to 300R: Crop set to 300L: Example of Image Crop set to Example of Image Crop set to 200B:...
  • Page 181 S - Pixel Ship Pixel Ship sizes an image in proportion to its original size. It decimates the image by shipping only certain, regularly spaced pixels. For example, 4S would transmit every fourth pixel from every fourth line. The smaller number of pixels shipped, the smaller the image, however, after a certain point the image becomes unusable.
  • Page 182 This filter typically provides better JPEG compression than the standard E - Edge Sharpen command (see page 8-15). This filter also works well when shipping pure black and white images (1 bit per pixel). The optimal setting is 26U. Document image filter off (default) 26U Apply document image filter for typical document image Apply document image filter using grayscale threshold n.
  • Page 183: Image Size Compatibility

    W - Histogram Ship A histogram gives a quick picture of the tonal range of an image, or key type. A low-key image has detail concentrated in the shadows; a high-key image has detail concentrated in the highlights; and an average-key image has detail concentrated in the midtones.
  • Page 184 2 of 5. Once one of these symbologies has been read, the image is retained for a possible IMGBOX command. The following IMGBOX example was executed and viewed using QuickView software. This software is available at www.honeywell.com/aidc. Click on Soft- ware Downloads. Select 4820 from the Products list, then select QuickView Software Utility.
  • Page 185: Imgbox Modifiers

    IMGBOX Modifiers A - Output Image Width This option is used to size the image horizontally. If using this option, set the resolution (R) to zero. Example of Image Width set to 200A: Example of Image Width set to 600A: B - Output Image Height This option is used to size the image vertically.
  • Page 186 F - File Format This option indicates the type of file format in which to save the image. KIM format TIFF binary TIFF binary group 4, compressed TIFF grayscale Uncompressed Binary Uncompressed grayscale JPEG image (default) Outlined image BMP format H - Height of Signature Capture Area The height of the signature capture area must be measured in inches divided by .01.
  • Page 187 R - Resolution of Signature Capture Area The resolution is the number of pixels that the imager outputs per each minimum bar width. The higher the value for R, the higher the quality of the image, but also the larger the file size. Values begin at 1000. The imager automatically inserts a decimal point between the first and second digit.
  • Page 188: Rf Default Imaging Device

    X - Horizontal Barcode Offset The horizontal barcode offset allows you to offset the horizontal center of the signature capture area. Positive values move the horizontal center to the right and negative values to the left. Measurements are in multiples of the minimum bar width.
  • Page 189: Chapter 9 - Ocr Programming

    OCR Programming Use this section to program the image scanner for optical character recognition (OCR). The image scanner reads 6 to 60 point OCR typeface. Note: OCR is not as secure as barcodes. To enhance security in OCR applications, create an OCR template to match the data and print an OCR check character.
  • Page 190: U.s. Currency Font

    OCR-B On allows you to scan characters in the OCR-B font. The default set- ting allows you to scan any eight digit combination. If you have created an OCR template, character combinations that fit the template can be scanned (see Creating an OCR Template, page 9-3).
  • Page 191: Semi Font

    SEMI Font SEMI Font On allows you to scan the SEMI font used in the semiconductor industry. SEMI Font On All OCR Off turns off all OCR capability in the image scanner, so the image scanner will be able to scan linear, stacked, matrix, and composite barcodes, but not OCR fonts.
  • Page 192: Template Characters

    Template Characters represents any alphanumeric character (digit or letter) represents a check character position represents any digit represents any available OCR character represents character from user-defined variable “g” represents character from user-defined variable “h” represents character from user-defined variable “g” or “h” represents that a check character is verified but transmitted represents any uppercase letter marks the start of a new template...
  • Page 193: Stringing Together Multiple Formats (Creating "Or" Statements)

    Character Match Sequences This method is used if you need a template that shows a specific character in a specific position. Put the character in uppercase in the template at the required position (template characters are always lower case). Example: You need to read three variable digits, three specific characters (ABC), followed by three variable digits.
  • Page 194: Ocr User-Defined Variables

    To create this template, you would enable the OCR-A font. Scan the Enter OCR Template symbol (page 9-13). Scan the d from the OCR Programming Chart in the back of this manual eight times, then scan the t to create the “or” statement.
  • Page 195: Reading Multi-Row Ocr

    Reading Multi-Row OCR The image scanner is capable of decoding multi-row OCR text. Note: Reading rows longer than sixteen characters is not recommended. Consider the following example. This example shows serial commands as they would be entered using QuickView. Example: You need to read multiple rows of OCR-A data as shown below: 12345678 ABCDEFGH First, enable the OCR-A font.
  • Page 196: Ocr Modulo 10 Check Character

    character. The image scanner transmits the OCR data without the check char- acter data. You must specify the location of the check character in the template with a c. Example: You need to read any combination of seven digits, with a modulo 10 check character in the eighth position.
  • Page 197 for the calculation. By default, the check character computation is unweighted, but the image scanner also supports two weighted modulo 10 checking schemes. Example: To program a modulo 11 check character, you would enter the following 11 characters in order: 0123456789X Also enter the OCR template: dddddddc...
  • Page 198: Weighting Options

    Weighting Options By default, the check character computation is unweighted. It is possible to use one of two weighted modulo 10 schemes. Weighting is often used to detect if two neighboring characters are transposed, a common error when an operator keys in data.
  • Page 199: Ocr Isbn Application Example

    checking scheme used in MSI Code and in Code 32 Pharmaceutical (PARAF). To apply this weighting scheme, set the OCR check character to "0123456789x2x1" or scan the following symbol: 2-1-2-1 Weighted Modulo 10 Check Character Example: Scan the 2-1-2-1 Weighted Modulo 10 Check Character symbol. Also enter the OCR template: ddddddc Then scan the string below:...
  • Page 200 0123456789- 3. In Japan, it is common for two fields to follow the ISBN number, the three digit price field, and the four digit price field. The first field typically starts with a “C” (uppercase c), followed by four digits. The second field typically starts with a “P”...
  • Page 201: Ocr Template Codes

    OCR Template Codes Note: Reading more than three rows of OCR is not recommended. Contact the factory if you have an application that requires reading four or more rows of OCR. † Enter OCR Template Enter User-Defined † Variable “g” Enter User-Defined †...
  • Page 202 9 - 14...
  • Page 203: Chapter 10 - Interface Keys

    Interface Keys Keyboard Function Relationships The following Keyboard Function Code, Hex/ASCII Value, and Full ASCII “CTRL”+ relationships apply to all terminals that can be used with the image scanner. Refer to page 2-13 enable Control + ASCII mode. Function Code HEX/ASCII Value Full ASCII “CTRL”...
  • Page 204 The last five characters in the Full ASCII “CTRL”+ column ( [ \ ] 6 - ), apply to US only. The following chart indicates the equivalents of these five characters for different countries. Country Codes United States Belgium < Scandinavia <...
  • Page 205: Supported Interface Keys

    Supported Interface Keys IBM AT/XT and PS/2 Compatibles, IBM XTs and IBM, DDC, Memorex WYSE PC/AT Compatibles Telex, Harris* ASCII Supported Keys Supported Keys Supported Keys Reserved Reserved Reserved Enter (KP) CR/Enter Enter Cap Lock Caps Lock ALT make Reserved ALT break Reserved CTRL make...
  • Page 206 Supported Interface Keys IBM, Memorex Telex (102)* Memorex Telex (88)** ASCII Supported Keys Supported Keys Reserved Reserved Enter Enter PF10 PF11 PF12 Reserved Reserved New Line New Line Field Forward Field Forward Reserved Tab/Field Forward Field Forward Delete Delete Field Exit New Line Insert Insert...
  • Page 207 Supported Interface Keys Esprit 200, 400 Esprit 200, 400 Esprit 200, 400 ANSI ASCII ASCII Supported Keys Supported Keys Supported Keys Reserved Reserved Reserved New Line New Line New Line New Line New Line New Line Delete New Line New Line New Line Insert Escape...
  • Page 208 Supported Interface Keys Apple Mac/iMac ASCII Supported Keys Reserved Enter/Numpad Enter CAPS ALT make ALT break CNTRL make CNTRL break RETURN APPLE make APPLE break RETURN Ins Help Home Prnt Scrn BACKSPACE LSHIFT TAB BACKSPACE 10 - 6...
  • Page 209: Chapter 11 - Utilities

    Utilities To Add a Test Code I.D. Prefix to All Symbologies This selection allows you to turn on transmission of a Code I.D. before the decoded symbology. (See the Symbology Chart, beginning on page A-1) for the single character code that identifies each symbology.) This action first clears all current prefixes, then programs a Code I.D.
  • Page 210: Show Scan Driver Revision

    Show Scan Driver Revision Scan the barcode below to output the scan driver revision. The scan driver con- trols image capture. Show Scan Driver Revision Show Software Revision Scan the barcode below to output the current software revision, unit serial num- ber, and other product information for both the image scanner and base.
  • Page 211: Image Scanner Report

    Image Scanner Report Scan the barcode below to generate a report for the connected image scanners. The report indicates the port, work group, image scanner name, and address. To assign a name to your image scanner, refer to "Menu Command Syntax" page 12-1.
  • Page 212: Resetting The Standard Product Default Settings: All Application Work Groups

    Menu Commands starting on page 12-5 list the factory default settings for each of the commands (indicated by an asterisk (*) on the programming pages). Note: Scanning this barcode also causes both the image scanner and the base to perform a reset and become unlinked. The image scanner must be placed in its base to re-establish the link before any setup codes are entered.
  • Page 213: Visual Xpress Introduction

    Visual Xpress Introduction Note: Software revision 31205480-118 or higher is backward compatible with all non-advanced illumination units. This new revision of software can be flashed in non-advanced illumination units for full backward compatibility. Software 31205480-090 or lower cannot be flashed into units with advanced illumination.
  • Page 214: Installing Visual Xpress From The Web

    Barcode information and images are displayed in the QuickView window. Installing QuickView from the Web 1. Access the Honeywell web site at www.honeywell.com/aidc. 2. Click on the Resources tab. Select Product Downloads-Software. 3. Click on the dropdown for Select Product Number. Click on 4820.
  • Page 215: Temporary Quickview Configuration

    4. Click on the listing for Quick*View Software Utility. 5. When prompted, select Save, and save the files to the c:\windows\temp directory. 6. Once you have finished downloading the file, exit the web site. 7. Using Explorer, go to the c:\windows\temp file. 8.
  • Page 216 11 - 8...
  • Page 217: Chapter 12 - Serial Programming Commands

    Serial Programming Commands The serial programming commands can be used in place of the programming barcodes. Both the serial commands and the programming barcodes will pro- gram the image scanner. For complete descriptions and examples of each serial programming command, refer to the corresponding programming barcode in this manual.
  • Page 218: Query Commands

    Data The new value for a menu setting, identified by the Tag and Sub- Tag. Storage A single character that specifies the storage table to which the command is applied. An exclamation point (!) performs the com- mand’s operation on the device’s volatile menu configuration table. A period (.) performs the command’s operation on the device’s non-volatile menu configuration table.
  • Page 219: Responses

    Responses The device responds to serial commands with one of three responses: ACK Indicates a good command which has been processed. ENQ Indicates an invalid Tag or SubTag command. NAK Indicates the command was good, but the Data field entry was out of the allowable range for this Tag and SubTag combination, e.g., an entry for a minimum message length of 100 when the field will only accept 2 charac- ters.
  • Page 220: Trigger Commands

    Example #4: What are the device’s settings for all Codabar selections? Enter: cbr?. Response: CBRENA1[ACK], SSX0[ACK], CK20[ACK], CCT1[ACK], MIN2[ACK], MAX60[ACK], DFT[ACK]. This response indicates that the device’s Codabar Coding Enable (CBRENA) is set to 1, or on; the Start/Stop Character (SSX) is set to 0, or Don’t Transmit; the Check Character (CK2) is set to 0, or Not Required;...
  • Page 221: Menu Commands

    Menu Commands Serial Setting Command Selection Page * Indicates default # Indicates a numeric entry Factory Default Settings All Application Work Default 3-11 PAPDFT Groups Current Application Default 3-11 DEFALT Work Group Terminal Interfaces Terminal ID *003 TERMID### 12 - 5...
  • Page 222 Serial Setting Command Selection Page * Indicates default # Indicates a numeric entry *U.S.A. 2-10 KBDCTY0 Belgium 2-10 KBDCTY1 Brazil 2-10 KBDCTY16 Canada (French) 2-10 KBDCTY18 Czech Republic 2-10 KBDCTY15 Denmark 2-10 KBDCTY8 Finland (Sweden) 2-10 KBDCTY2 France 2-10 KBDCTY3 Germany/Austria 2-10 KBDCTY4...
  • Page 223 Serial Setting Command Selection Page * Indicates default # Indicates a numeric entry *Regular 2-12 KBDSTY0 Caps Lock 2-12 KBDSTY1 Shift Lock 2-13 KBDSTY2 Keyboard Style Automatic Caps Lock 2-13 KBDSTY6 Emulate External 2-13 KBDSTY5 Keyboard *Control + ASCII Off 2-14 KBDCAS0 DOS Mode Control +...
  • Page 224 Serial Setting Command Selection Page * Indicates default # Indicates a numeric entry 7 Data, 1 Stop, Parity 2-17 232WRD3 Even 7 Data, 1 Stop, Parity 2-17 232WRD0 None 7 Data, 1 Stop, Parity 2-17 232WRD6 7 Data, 2 Stop, Parity 2-17 232WRD4 Even...
  • Page 225: Basic System Operation

    Serial Setting Command Selection Page * Indicates default # Indicates a numeric entry 2-23 WNDDLY0 *50ms 2-23 WNDDLY1 Delay Between Blocks 150ms 2-23 WNDDLY2 500ms 2-23 WNDDLY3 2-23 WNDCHK1 Overall Checksum *Off 2-23 WNDCHK0 2-24 WNDSPD0 2-24 WNDSPD1 2-24 WNDSPD2 Wand Emulation 2-24 WNDSPD3...
  • Page 226 Serial Setting Command Selection Page * Indicates default # Indicates a numeric entry Image Scanner Image Scanner Report RPTSCN Report *Group 0 3-10 GRPSEL0 Group 1 3-10 GRPSEL1 Group 2 3-10 GRPSEL2 Application Work Group Group 3 3-10 GRPSEL3 Selections Group 4 3-10 GRPSEL4...
  • Page 227: Output Selections

    Serial Setting Command Selection Page * Indicates default # Indicates a numeric entry *Off 3-23 BATDLY0 Short (ms) 3-23 BATDLY250 Batch Mode Transmit Delay Medium (ms) 3-23 BATDLY500 Long (ms) 3-23 BATDLY1000 Output Selections BEPBEP0 Beeper - Good Read BEPBEP1 BEPLVL0 Beeper Volume - BEPLVL1...
  • Page 228 Serial Setting Command Selection Page * Indicates default # Indicates a numeric entry *Manual/Serial Trigger TRGMOD0 Read Time-Out (0 - 300,000 ms) TRGSTO#### *30,000 BT_LPT0 Trigger Mode BT_LPT200 Image Scanner Power BT_LPT400 Time-Out Timer (0-7200 BT_LPT900 seconds) *3600 BT_LPT3600 BT_LPT7200 Scan Stand Mode TRGMOD4 Scan Stand...
  • Page 229 Serial Setting Command Selection Page * Indicates default # Indicates a numeric entry *Lights On 4-11 SCNLED1 Illumination Lights Lights Off 4-11 SCNLED0 200 milliseconds 4-12 SCNDLY200 Aimer Delay 400 milliseconds 4-12 SCNDLY400 *Off (no delay) 4-12 SCNDLY0 User-Specified Aimer Range 0 - 4,000 ms 4-12 SCNDLY####...
  • Page 230: Prefix/Suffix Selections

    Serial Setting Command Selection Page * Indicates default # Indicates a numeric entry Enter Sequence 4-19 SEQBLK Output Sequence Editor Default Sequence 4-19 SEQDFT Required 4-20 SEQ_EN2 Require Output On/Not Required 4-20 SEQ_EN1 Sequence *Off 4-20 SEQ_EN0 4-20 SHOTGN1 Multiple Symbols *Off 4-20 SHOTGN0...
  • Page 231: Data Formatter Selections

    Serial Setting Command Selection Page * Indicates default # Indicates a numeric entry Delay Length DLYCRX## (0 - 495 ms) User Specified Intercharacter Delay Character to Trigger DLY_XX### Delay Interfunction Delay Range 0 - 495 ms DLYFNC## Intermessage Delay Range 0 - 495 ms DLYMSG## Data Formatter Selections *Default Data Format...
  • Page 232 Serial Setting Command Selection Page * Indicates default # Indicates a numeric entry *Off CBRCCT0 Codabar CBRCCT1 Concatenation Require CBRCCT2 Minimum (2 - 60) *4 CBRMIN## Codabar Message Length Maximum (2 - 60) *60 CBRMAX## Default All Code 39 Code 39 C39DFT Settings C39ENA0...
  • Page 233 Serial Setting Command Selection Page * Indicates default # Indicates a numeric entry *No Check Char. 7-10 I25CK20 Interleaved 2 of 5 Validate, But Don’t 7-10 I25CK21 Check Digit Transmit Validate, and Transmit 7-10 I25CK22 Minimum (2 - 80) *4 7-10 I25MIN## Interleaved 2 of 5...
  • Page 234 Serial Setting Command Selection Page * Indicates default # Indicates a numeric entry Minimum (1 - 80) *4 7-14 X25MIN## Matrix 2 of 5 Message Length Maximum (1 - 80) *80 7-14 X25MAX## Default All Code 11 Code 11 7-15 C11DFT Settings *Off...
  • Page 235 Serial Setting Command Selection Page * Indicates default # Indicates a numeric entry 7-19 UPACKX0 UPC-A Check Digit 7-19 UPACKX1 7-19 UPANSX0 UPC-A Number System 7-19 UPANSX1 *Off 7-20 UPAAD20 UPC-A 2 Digit Addenda 7-20 UPAAD21 *Off 7-20 UPAAD50 UPC-A 5 Digit Addenda 7-20 UPAAD51...
  • Page 236 Serial Setting Command Selection Page * Indicates default # Indicates a numeric entry 2 Digit Addenda On 7-23 UPEAD21 *2 Digit Addenda Off 7-23 UPEAD20 UPC-E0 Addenda 5 Digit Addenda On 7-23 UPEAD51 *5 Digit Addenda Off 7-23 UPEAD50 *Off 7-24 UPEEN10 UPC-E1...
  • Page 237 Serial Setting Command Selection Page * Indicates default # Indicates a numeric entry *2 Digit Addenda Off 7-27 EA8AD20 2 Digit Addenda On 7-27 EA8AD21 EAN/JAN-8 Addenda *5 Digit Addenda Off 7-27 EA8AD50 5 Digit Addenda On 7-27 EA8AD51 *Not Required 7-27 EA8ARQ0 EAN/JAN-8 Addenda...
  • Page 238 Serial Setting Command Selection Page * Indicates default # Indicates a numeric entry GS1 DataBar Default All GS1 DataBar 7-30 RSEDFT Expanded Expanded Settings 7-31 RSEENA0 GS1 DataBar Expanded 7-31 RSEENA1 GS1 DataBar Minimum (4 - 74) *4 7-31 RSEMIN## Expanded Msg.
  • Page 239 Serial Setting Command Selection Page * Indicates default # Indicates a numeric entry Default All Code 49 Code 49 7-34 C49DFT Settings 7-35 C49ENA0 Code 49 7-35 C49ENA1 Minimum (1 - 81) *1 7-35 C49MIN## Code 49 Msg. Length Maximum (1 - 81) *81 7-35 C49MAX## Default All PDF417...
  • Page 240 Serial Setting Command Selection Page * Indicates default # Indicates a numeric entry 7-39 4CBENA1 Intelligent Mail Barcode *Off 7-39 4CBENA0 7-40 TAGENA1 ID-tag (UPU 4-State) *Off 7-39 TAGENA0 7-39 T39ENA1 TCIF Linked Code 39 (TLC39) *Off 7-39 T39ENA0 7-40 NETENA1 Postnet *Off...
  • Page 241 Serial Setting Command Selection Page * Indicates default # Indicates a numeric entry Minimum (2 - 80) *4 7-44 CPCMIN## China Post Msg. Length Maximum (2 - 80) *80 7-44 CPCMAX## Default All Korea Post Korea Post 7-45 KPCDFT Settings *Off 7-45 KPCENA0...
  • Page 242 Serial Setting Command Selection Page * Indicates default # Indicates a numeric entry Minimum (1-3832) *1 7-49 AZTMIN Aztec Code Msg. Maximum (1-3832) Length 7-49 AZTMAX *3832 Enable Runes 7-49 AZTRUN1 Aztec Runes *Disable Runes 7-49 AZTRUN0 Chinese Sensible 7-50 HX_ENA1 (Han Xin) Code HX_ENA0...
  • Page 243: Imaging Default Commands

    Serial Setting Command Selection Page * Indicates default # Indicates a numeric entry Imaging Default Commands Default all Imaging IMGDFT Commands Imaging Style - SNPSTY0 Decoding *Imaging Style - Photo SNPSTY1 Imaging Style - Manual SNPSTY2 Beeper On SNPBEP1 *Beeper Off SNPBEP0 *Wait for Trigger Off SNPTRG0...
  • Page 244 Serial Setting Command Selection Page * Indicates default # Indicates a numeric entry *Infinity Filter - Off IMGINF0 Infinity Filter - On IMGINF1 *Compensation Off IMGCOR0 Compensation On IMGCOR1 *Pixel Depth - 8 bits/ IMGBPP8 pixel (grayscale) Pixel Depth - 1 bit/pixel IMGBPP1 (B&W) *Don’t Sharpen Edges...
  • Page 245: Ocr Selections

    Serial Setting Command Selection Page * Indicates default # Indicates a numeric entry Image Crop - Left (0- 8-11 IMGWNL### 640) *0 Image Crop - Right (0- 8-11 IMGWNR### 640) *639 Image Crop - Top (0- 8-11 IMGWNT### 480) *0 Image Crop - Bottom (0- 8-12 IMGWNB###...
  • Page 246: Minimizing Bluetooth/Ism Band Network Activity

    Serial Setting Command Selection Page * Indicates default # Indicates a numeric entry OCR Mod. 10 Check “OCRCHK012345 Char. 6789” “OCRCHK012345 6789ABCDEFGHI OCR Mod. 36 Check JKLM- Char. NOPQRSTU- OCR Check VWXYZ” Character OCR User-Defined OCRCHK Check Char. 3-1-3-1 Weighted Mod. 9-10 OCRCHK3-1-3-1 10 Check Char.
  • Page 247: Chapter 13 - Product Specifications

    Product Specifications 4820 Product Specifications Parameter Specification Dimensions (Typical): Height 6.2 inches (15.7 cm) Length 5.3 inches (13.5 cm) Width 3.2 inches (8.1 cm) Weight 9.2 ounces (260.8 g) Aimer: Illumination LEDs 617nm +30nm Aiming LEDs 526nm +30nm 752x480 Image Binary, TIFF, or JPEG output ±40 degrees Skew Angle...
  • Page 248 Vibration Withstands 5G peak from 22 to 300 Hz ESD Sensitivity 15 kV to any external surface per MIL-HDBK-217F Ground Benign exceeds 71,000 MTBF hours Sealant Rating IP41 *Storage outside of this temperature range could be detrimental to battery life. 13 - 2...
  • Page 249: 4820I Product Specifications

    4820i Product Specifications Parameter Specification Dimensions (Typical): Height 6.5 in. (16.5 cm) Length 5.3 inches (13.5 cm) Width 3.2 inches (8.1 cm) Weight 9.6 oz. (272 g) Aimer: Illumination LEDs 626nm +30nm Aiming LEDs 526nm +30nm 752x480 Image Binary, TIFF, or JPEG output ±40 degrees Skew Angle ±40 degrees...
  • Page 250: 2020-5 Product Specifications

    Vibration Withstands 5G peak from 22 to 300 Hz ESD Sensitivity 15 kV to any external surface per MIL-HDBK-217F Ground Benign exceeds 71,000 MTBF hours Sealant Rating IP54 *Storage outside of this temperature range could be detrimental to battery life. 2020-5 Product Specifications Parameter Specification...
  • Page 251 Operational after 50 drops from 3.3 feet (1 m) to Mechanical Drop concrete Vibration Withstands 5G peak from 22 to 300 Hz ESD Sensitivity 15 kV to any external surface 13 - 5...
  • Page 252 Standard Cable Pinouts Keyboard Wedge 13 - 6...
  • Page 253 Standard Cable Pinouts Wand Emulation 13 - 7...
  • Page 254 Standard Cable Pinouts Serial Output 13 - 8...
  • Page 255 Standard Cable Pinouts 13 - 9...
  • Page 256 13 - 10...
  • Page 257: Chapter 14 - Maintenance

    Maintenance Repairs Repairs and/or upgrades are not to be performed on this product. These ser- vices are to be performed only by an authorized service center (see Customer Support on page 15-1). Maintenance The cordless system provides reliable and efficient operation with a minimum of care.
  • Page 258: Replacing The 2020 Interface Cable

    Replacing the 2020 Interface Cable: 1. Turn the power to the host system OFF. 2. Disconnect the base’s cable from the terminal or computer. 3. Turn the base upside down. 4. Pull the connector out while maintaining pressure on the connector release clip.
  • Page 259: Assembling The Battery Charge Sleeve Kit

    Assembling the Battery Charge Sleeve Kit Attach Tether 1. Use the phillips screw to connect the metal ring of the coiled tether to the battery charge sleeve. 2. Peel the backing from the metal plate on the coiled tether and affix the metal plate to the back of the 2020 base.
  • Page 260: Troubleshooting The Base

    Troubleshooting the Base Note: Please visit the Services and Support section of our website (www.honeywell.com/aidc) to check for the latest software for both the image scanner and the base. If your base is not functioning properly, review the following troubleshooting guidelines to try to isolate the problem.
  • Page 261 • Aren’t smeared, rough, scratched, or exhibiting voids. • Aren’t coated with frost or water droplets on the surface. • Are enabled in the base to which the image scanner connects. Is the barcode displayed but not entered into the application? The barcode is displayed on the host device correctly, but you still have to press a key to enter it (the Enter/Return key or the Tab key, for example).
  • Page 262 14 - 6...
  • Page 263: Chapter 15 - Customer Support

    Telephone - Hong Kong: +852-3188-3485 or 2511-3050 Telephone - China: +86 21 6361 3818 E-mail: [email protected] Japan Telephone: +813 5770-6312 E-mail: [email protected] Malaysia Telephone: +603-6201-7020 E-mail: [email protected] Online Technical Assistance You can also access technical assistance online at www.honeywell.com/aidc. 15 - 1...
  • Page 264: Product Service And Repair

    Product Service and Repair Honeywell International Inc. provides service for all its products through service centers throughout the world. To obtain warranty or non-warranty service, con- tact the appropriate location below to obtain a Return Material Authorization number (RMA #) before returning the product.
  • Page 265: Limited Warranty

    Limited Warranty Honeywell International Inc. ("HII") warrants its products to be free from defects in materials and workmanship and to conform to HII’s published specifications applicable to the products purchased at the time of shipment. This warranty does not cover any HII product which is (i) improperly installed or used; (ii) dam- aged by accident or negligence, including failure to follow the proper mainte- nance, service, and cleaning schedule;...
  • Page 266 QUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU. All provisions of this Limited Warranty are separate and severable, which means that if any provision is held invalid and unenforceable, such determina- tion shall not affect the validity of enforceability of the other provisions hereof. Use of any peripherals not provided by the manufacturer may result in damage not covered by this warranty.
  • Page 267: Appendix A - Reference Charts

    Reference Charts Symbology Chart Possible AIM Code ID Symbology AIM ID ID Modifiers (hex) ( m ) All Symbologies (0x99) Australian Post A (0x41) Aztec Code z (0x7A) 0-9, A-C British Post B (0x42) Canadian Post C (0x43) China Post Q (0x51) Chinese Sensible Code (Han Xin H (0x48)
  • Page 268 Possible AIM Code ID Symbology AIM ID ID Modifiers (hex) ( m ) Intelligent Mail Barcode M (0x4D) Interleaved 2 of 5 0, 1, 3 e (0x65) Japanese Post J (0x4A) KIX (Netherlands) Post K (0x4B) Korea Post ? (0x3F) Matrix 2 of 5 m (0x6D) MaxiCode...
  • Page 269 Note: “m” represents the AIM modifier character. Refer to International Technical Specification, Symbology Identifiers, for AIM modifier character details. Prefix/Suffix entries for specific symbologies override the universal (All Symbologies, 99) entry. Refer to Data Editing beginning on page 5-1 and Data Formatting beginning on page 6-1 for information about using Code ID and AIM ID.
  • Page 270: Ascii Conversion Chart (Code Page 1252

    ASCII Conversion Chart (Code Page 1252 Note: This table applies to U.S. style keyboards. Certain characters may differ depending on your Country Code/PC regional settings. Dec Hex Char Hex Char Dec Char Dec Hex Char ‘ “ & ‘ < >...
  • Page 271 Char Char Dec Char Dec Char € € À à ¡ Á á ‚ ¢ Â â ƒ £ Ã ã „ ¤ Ä ä … ¥ Å å † ¦ Æ æ ‡ § Ç ç ˆ ¨ È è...
  • Page 272: Code Page Mapping Of Printed Barcodes

    Code Page Mapping of Printed Barcodes Code pages define the mapping of character codes to characters. If the data received does not display with the proper characters, it may be because the barcode being scanned was created using a code page that is different from the one the host program is expecting.
  • Page 273: Appendix B - Minimizing Bluetooth/Ism Band Network Activity

    Minimizing Bluetooth/ISM Band Network Activity The settings described below can help you customize the re-linking behavior of the cordless linear imaging system to obtain the best compromise between con- venience and low interference. Note: ISM band refers to the 2.4 to 2.48 GHz frequency band used by wireless networks, cordless phones, and Bluetooth.
  • Page 274: Maximum Link Attempts

    Event Auto Reconnect On Auto Reconnect Off Image scanner Re-link occurs automatically. reset due to firmware upgrade Image scanner Re-link occurs automatically. reset due to battery change Image scanner Re-link to new base occurs automatically. placed in different base unit Maximum Link Attempts The Maximum Link Attempts setting controls the number of times the image scanner tries to form a connection with a base unit or PC.
  • Page 275: Bluetooth/Ism Network Activity Examples

    Scan the Relink Time-Out barcode, then scan the number of seconds for the setting (from 1-100) from the inside back cover. Scan Save to save the setting. Default = 3 seconds. Relink Time-Out Bluetooth/ISM Network Activity Examples Default values: When the image scanner goes out of range, the image scanner repeatedly attempts to connect to base unit.
  • Page 276 B - 4...
  • Page 278: Sample Symbols

    Sample Symbols UPC-A Interleaved 2 of 5 0 123456 7890 Code 128 1234567890 EAN-13 Code 128 Code 39 9 780330 290951 Codabar BC321 Code 93 A13579B Straight 2 of 5 Industrial 123456-9$ 123456...
  • Page 279 Sample Symbols Matrix 2 of 5 GS1 DataBar 6543210 PDF417 (01)00123456789012 Postnet Car Registration Zip Code Code 49 Data Matrix 1234567890 QR Code Test Symbol Numbers 4-CB (4-State Customer Barcode) 01,234,567094,987654321,01234567891 ID-tag (UPU 4-State) J18CUSA8E6N062315014880T...
  • Page 280 Sample Symbols Aztec Micro PDF417 Package Label MaxiCode Test Message OCR-B with Modulo 10 check character Test Message OCR-A with Modulo 36 check character...
  • Page 281: Ocr Programming Chart

    OCR Programming Chart Save Discard...
  • Page 282: Programming Chart

    Programming Chart...
  • Page 283 Programming Chart Save Discard Reset Note: If you make an error while scanning the letters or digits (before scanning Save), scan Discard, scan the correct letters or digits, and Save again.
  • Page 284 Honeywell 700 Visions Drive P.O. Box 208 Skaneateles Falls, NY 13153-0208 4820-UG Rev F 2/09...

This manual is also suitable for:

202048204820i