Haier HSU-09LA10 User Manual

User manual
Hide thumbs Also See for HSU-09LA10:

Quick Links

REMOTE CONTROLLER

It sends signals to the indoor unit.
DISPLAY button
Press it once to stop the indoor
unit displaying and press again
to make it display.
SLEEP button
Please see"sleep mode".
SLEEP DISPLAY TIMER
OPERATION
MODE button
Press it to select operation mode:
AUTO
COOL
DRY
HEAT
FAN
TEMPERATURE
ADJUSTMENT buttons
Press it once, the setting tempera-
-ture decreases by
1 .The range of
setting temperature is 16-31 .
FAN SPEED button
Press it to change the fan speed
in the order of low-medium-high
-auto (
).
AUTO
UP&DOWN SWING button
Please see"adjustment of air flow
direction".
NOTICE:
Cool only type has no HEAT mode.
To operate, the distance should be within 6 meters from the indoor unit with a clear
line of sight.
Remove the batteries if the remote controller is not to be used for long periods of time.
As this is a all-purpose remote controller which contains many functional buttons, please refer
to the function of the air conditioner to know about the actual function.
Don't tear the batteries apart or throw them into fire, which will lead to irreparable damage.
When transferring from one mode to another, it may needs less than 3 minutes' delay
to protect compressor.
OPERATION MODE ADJUSTMENT
1.

AUTO mode

AUTO
In this mode, the air conditioner can automatically adjust the room
temperature to decide the most suitable temperature. At the start of
operation, the air conditioner will automatically select the operation mode
according to the room temperature. The following table shows the
conditions which are set at start up.
Cool only type
Room
Temperature (RT)
Initial Setting Temperature
Mode
RT 26
Cool
26
RT 25
25
RT 23
Dry
Rt 23
2.

COOL mode

Press UP & DOWN SWING button to change up/down air flow direction
and LEFT & RIGHT SWING button to change left/right air flow direction.
Press FAN SPEED button to change the fan speed of indoor unit.
Press TEMPERATURE ADJUSTMENT button to change the set temperature.
3.

DRY mode

In this mode, the air conditioner automatically sets the room temperature
and this temperature will not appear on display.
TEMPERATURE ADJUSTMENT button and FAN SPEED button are not
functional.
Press UP & DOWN SWING button or LEFT & RIGHT SWING button to
change air flow direction.
4.

FAN mode

In this mode, the outdoor unit does not operate. The indoor fan alone
operates.
Press UP & DOWN SWING button or LEFT & RIGHT SWING button to
change air flow direction.
Press FAN SPEED button to change the fan speed of indoor unit.
Signal ejecting window
OPERATION DISPLAY
It displays the current
123
hours OnOff
settings.
AUTO
¡æ
TIMER SET/CLOCK button
SWING FAN AUTO SWING
Press it to fix the timer setting or
set the clock to the present time.
TURBO
/CL.
TURBO button
Press it to start turbo function
MODE
and press again to stop it.
I/O
RUN/STOP button
FAN SPEED
Turns unit ON/OFF.
INOIZER
TEMPERATURE
ADJUSTMENT buttons
Press it once, the setting tem-
-perature increases by
LEFT&RIGHT SWING button
Please see"adjustment of air flow
direction".
INOIZER button
Press it to start inoizer function
and press again to stop it.
1
Heat pump type
Mode
Initial Setting Temperature
24
24
Cool
RT-2
RT-2
Dry
RT-2
RT-2
21
Heat
26
3
TIMER&SET OPERATION

Timer operation

ON/OFF timer operation set
Press button Timer/
OFF or ON TIMER function.
Every press of button Timer/
hours at most).
to
ON/OFF timer operation cancellation
If you want timer operation cancelled, press button Timer/
of timer"
",the time and "hours on" or "hours off" disappear on the remote
controller display.
Note: When the air conditioner is on timer operation,if you want to reset the
timer you must cancel the former timer, or the setting will not in accord with
actual condition.
Clock set
As long as the remote controller is on power, the clock will run all the time
1 .
and it can be adjusted in any condition even when the air conditioner is off.
While the air conditioner is electrified for the first time, the time of the clock
is " 0:00 ", the flash of ": " means the clock counts the time automatically.
Press the button "Timer/ " for 3 seconds, the time of the clock can be
adjusted. At that time the time of hour flashes, during this period you can
add the time of hours by pressing the button "
pressing the button"
Timer/
again to adjust the time of minute(do not need to press it for 3
CL
seconds).When the time of minute flashes, press the button"
time of minute, and press the button "
of minute, press the button "Timer/ " for the third time to confirm the time of
the clock.
Note: The time of the clock will only display when the air conditioner isn't set
timer, otherwise it will not display.
5.
¡ ±
HEAT mode (only applied to heat pump type)
Press MANUAL SWING button or SWING button to change up/down air
flow direction.
Press FAN SPEED button to change the fan speed of indoor unit.
Press TEMPERATURE ADJUSTMENT button to change the set temperature.
6.
TURBO function (only applied to turbo series)
This function will make the air conditioner heat or cool quickly and during
this period, the noise of the air conditioner will increase. Turbo function
can be only started up in heat or cool mode(turbo heating or turbo cooling)
otherwise, it can not be started up. When the air conditioner is in cool or
heat mode, press turbo button to initiate turbo function, the remote con-
-troller displays "TURBO" and the icon of fan speed is "
the air conditioner cannot be controlled by the remote controller. Press
turbo button again or start up sleep mode or transit modes to exit turbo
function. After exiting turbo function the fan runs at low speed.
7.
ADJUSTMENT OF AIR FLOW DIRECTION
UP & DOWN SWING function
Every press of the UP & DOWN SWING button, the angle of the
up and down swing louver will change in the order of
swing icon displays dynamically, meanwhile the letter
displays above the icon.
LEFT & RIGHT SWING function(only applied to left
& right swing series)
Every press of the LEFT & RIGHT SWING button, the angle of the
swing louver will change in the order of
SWING
dynamically, meanwhile the letter
when the air conditioner is on or off to initiate the
CL
¡ ±
¡ ±
increases the ON/OFF time by one hour(24
CL
¡ ±
¡ ±
CL
" and reduce the time by
". After setting the time of hour, press the button
" to reduce it. Finish setting the time
CL
2
¡ ±
SWING
. When it swings automatically, the
. When it swings automatically, the swing icon displays
"
SWING
"
displays above the icon.
4
¡ ±
until the icon
CL
¡ ±
" to add the
",meanwhile
"
SWING
"
loading

Summary of Contents for Haier HSU-09LA10

  • Page 1: Remote Controller

    Note: The time of the clock will only display when the air conditioner isn't set Remove the batteries if the remote controller is not to be used for long periods of time. As this is a all-purpose remote controller which contains many functional buttons, please refer timer, otherwise it will not display.
  • Page 2 .The unit will continue operating at 3 above When the air conditioner is in cooling and dry mode, the indoor fan runs at the set temperature.7 hours later, the set temperature will decrease 1 . The low speed.After one hour of operation the set temperature will increase by unit will then continue operating at this temperature.

This manual is also suitable for:

Hsu-12la10 - annexe 1Hsu-18la10 - annexe 1