Siemens SIMATIC IFP1500 Operating Instructions Manual

Industrial monitors
Hide thumbs Also See for SIMATIC IFP1500:
Table of Contents

Quick Links

Industrial Flat Panel IFP1500, IFP1900,
IFP2200
SIMATIC
Industrial Monitors
Industrial Flat Panel IFP1500,
IFP1900, IFP2200
Operating Instructions
09/2012
A5E31298376-AA
___________________
Preface
___________________
Overview
___________________
Safety information
___________________
Installing and connecting the
device
___________________
Commissioning the device
___________________
Operating the device
___________________
IPC Wizard functions
___________________
Maintaining and servicing
your device
___________________
Technical information
___________________
Technical Support
___________________
List of abbreviations
1
2
3
4
5
6
7
8
A
B
Table of Contents
loading

Summary of Contents for Siemens SIMATIC IFP1500

  • Page 1 ___________________ Industrial Flat Panel IFP1500, IFP1900, Preface IFP2200 ___________________ Overview ___________________ Safety information SIMATIC ___________________ Installing and connecting the device Industrial Monitors ___________________ Industrial Flat Panel IFP1500, Commissioning the device IFP1900, IFP2200 ___________________ Operating the device Operating Instructions ___________________ IPC Wizard functions ___________________ Maintaining and servicing your device...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Preface

    Preface These operating instructions contain all the information you need for commissioning and operation of the SIMATIC Industrial Flat Panel IFP. It is intended both for programming and testing personnel who commission the device and connect it with other units (automation systems, programming devices), as well as for service and maintenance personnel who install add-ons or carry out fault/error analyses.
  • Page 4 Not with IFP1500 Touch/Key Extended Scope of this documentation The SIMATIC Industrial Flat Panel is supplied with the following documents: ● Quick Install Guide - SIMATIC IFP1500, IFP1900, IFP2200 Printed installation and commissioning instructions ● Operating instructions - SIMATIC IFP1500, IFP1900, IFP2200 You will find the operating instructions in PDF format on the "Documentation and Drivers"...
  • Page 5: Table Of Contents

    Table of contents Preface ..............................3 Overview..............................9 Product description ........................9 Scope of delivery .........................10 Construction of the devices......................11 1.3.1 IFP1500, IFP1900, IFP2200 Touch .....................11 1.3.2 IFP1500 Touch/Key ........................13 1.3.3 Interfaces .............................14 1.3.3.1 Standard versions ........................14 1.3.3.2 Extended versions ........................14 Accessories..........................15 Safety information............................
  • Page 6 Table of contents Commissioning the device ........................45 Operating the device..........................47 Overview ............................. 47 Operating the touch screen......................48 Using the on-screen keyboard ....................49 Operating a Touch/Key device....................50 IPC Wizard functions ..........................53 Overview ............................. 53 Calibrating the touch screen ....................... 53 Standard calibration ........................
  • Page 7 Table of contents Technical Support............................ 79 Service and support ........................79 List of abbreviations..........................81 Glossary ..............................83 Index................................ 85 Industrial Flat Panel IFP1500, IFP1900, IFP2200 Operating Instructions, 09/2012, A5E31298376-AA...
  • Page 8 Table of contents Industrial Flat Panel IFP1500, IFP1900, IFP2200 Operating Instructions, 09/2012, A5E31298376-AA...
  • Page 9: Overview

    Overview Product description SIMATIC Industrial Flat Panels are LCD monitors suitable for industrial use with a brilliant TFT display which can be connected to all SIMATIC IPCs as well as almost all generally available PCs. Features of SIMATIC Industrial Flat Panels ●...
  • Page 10: Scope Of Delivery

    Overview 1.2 Scope of delivery Additional features of the Extended versions ● Up to 30 m away from PC possible via DVI ● Power supply: 24 V DC and 100-240 V AC ● 2 USB ports ● Also available as touch/key version with front USB interface Scope of delivery The scope of delivery includes the following components: Name...
  • Page 11: Construction Of The Devices

    Overview 1.3 Construction of the devices Construction of the devices 1.3.1 IFP1500, IFP1900, IFP2200 Touch This section describes the structure of the monitor and touch devices, using the IFP1500 Touch as an example. Front view and side view ① Display/touch screen ②...
  • Page 12 Overview 1.3 Construction of the devices Rear view ① Rating plate ② Interface name ③ Protective conductor connection ④ Retaining elements for strain relief of the connecting cables Industrial Flat Panel IFP1500, IFP1900, IFP2200 Operating Instructions, 09/2012, A5E31298376-AA...
  • Page 13: Ifp1500 Touch/Key

    Overview 1.3 Construction of the devices 1.3.2 IFP1500 Touch/Key Front view ① Display and function keys with LED ② Alphanumeric keys ③ Control keys ④ Cursor keys ⑤ USB port Industrial Flat Panel IFP1500, IFP1900, IFP2200 Operating Instructions, 09/2012, A5E31298376-AA...
  • Page 14: Interfaces

    Overview 1.3 Construction of the devices 1.3.3 Interfaces 1.3.3.1 Standard versions ① X80 connector for 24 V DC power supply ② X71 DVI-D interface ③ X70 DisplayPort interface ④ X60 USB Type B 1.3.3.2 Extended versions ① ⑤ Connection for 100 to 240 V AC power X61/X62 USB Type A supply ②...
  • Page 15: Accessories

    1.4 Accessories Accessories This section contains the number of accessories available at the time of publication of the operating instructions. You will find additional accessories on the Internet at: ● Industry Mall (http://mall.automation.siemens.com) ● Expansion components and accessories (http://www.automation.siemens.com/ mcms/pc-based-automation/en/industrial-pc/expansion_components_accessories)
  • Page 16 Overview 1.4 Accessories Industrial Flat Panel IFP1500, IFP1900, IFP2200 Operating Instructions, 09/2012, A5E31298376-AA...
  • Page 17: Safety Information

    Safety information General safety instructions Open equipment and the Machinery Directive WARNING The device constitutes open equipment The device constitutes open equipment. This means that the device may only be installed in enclosures or cabinets which provide front access for operating the device. Access to the enclosure or cabinet in which the device is installed should only be possible by means of a key or tool and for trained and authorized personnel.
  • Page 18: Security Information

     Observe the information on electromagnetic compatibility (Page 62). Security information Siemens offers IT security mechanisms for its portfolio of automation and drive products in order to support safe operation of the plant/machine. We recommend that you stay informed about the IT security developments for your products. For information on this topic, refer to: Industry Online Support (http://www.siemens.de/automation/csi_en_WW): You can register...
  • Page 19: Notes About Usage

    Safety information 2.3 Notes about usage Notes about usage NOTICE Device approved for indoor use only The device may be damaged if operated outdoors. Operate the device indoors only. Industrial applications The device is designed for industrial use. It conforms to the following standards: ●...
  • Page 20 Safety information 2.3 Notes about usage Risk analysis and measures WARNING Hazards emanating from unprotected machines or plants The results of a risk analysis can reveal any hazards emanating from unprotected machinery. Such hazards may pose a risk of personal injury. You can prevent personal injury caused by hazards as specified in the risk analysis by taking the following measures: ...
  • Page 21 Safety information 2.3 Notes about usage TFT displays NOTICE Burn-in effect and backlight A permanent picture with bright images can result in a burn-in effect. The longer the same content is displayed on the screen, the longer it will take for the burn-in effect to disappear. Screen savers that active black when the backlight is on (e.g.
  • Page 22 Safety information 2.3 Notes about usage Industrial Flat Panel IFP1500, IFP1900, IFP2200 Operating Instructions, 09/2012, A5E31298376-AA...
  • Page 23: Installing And Connecting The Device

    Installing and connecting the device Preparing for installation 3.1.1 Checking the delivery Procedure 1. When accepting a delivery, please check the packaging for visible transport damage. 2. If any transport damage is present at the time of delivery, lodge a complaint at the shipping company in charge.
  • Page 24 Installing and connecting the device 3.1 Preparing for installation 6. If the contents of the packaging are incomplete, damaged or do not match your order, inform the responsible delivery service immediately. WARNING Electric shock and fire hazard due to damaged device A damaged device can be under hazardous voltage and trigger a fire in the machine or plant.
  • Page 25: Permitted Mounting Positions

    Installing and connecting the device 3.1 Preparing for installation 3.1.2 Permitted mounting positions The device is suitable for installation in: ● Mounting cabinets ● Control cabinets ● Switchboards ● Consoles In the following, all of these mounting options are referred to by the general term "cabinet". The device is self-ventilated and approved for inclined mounting at angles up to +/-35°...
  • Page 26 Installing and connecting the device 3.1 Preparing for installation Mounting in horizontal format All devices are suitable for horizontal mounting positions. 0 °C A maximum ambient temperature of +50 °C is permitted for vertical mounting of the IFP1500 (0° tilt angle); a maximum of +40 °C is permitted for inclined mounting. The ambient temperature for the IFP1900 and IFP2200 when installed vertically should not exceed +45 °C.
  • Page 27: Checking Clearances

    Installing and connecting the device 3.1 Preparing for installation 3.1.3 Checking clearances The following clearances are required around the device to ensure adequate self-ventilation: ● At least 15 mm to the right and left of the mounting cutout (in x direction) to allow for insertion of the mounting clamps during installation ●...
  • Page 28: Preparing The Mounting Cutout

    Installing and connecting the device 3.1 Preparing for installation 3.1.4 Preparing the mounting cutout Note Stability of the mounting cutout The material in the area of the mounting cutout must be sturdy enough to ensure permanent safe mounting of the device. The force of the clamps or operation of the device may not lead to deformation of the material in order to achieve the degrees of protection described below.
  • Page 29: Labeling The Function Keys

    Labeling strip templates are available in a Word document on the Internet at: Labeling strips for 15" widescreen (http://support.automation.siemens.com/DE/view/en/59000814) If you would like to make your own labeling strips, you can find the dimensions under "Dimensions for labeling strips (Page 69)".
  • Page 30 Installing and connecting the device 3.1 Preparing for installation The figure below shows the positions of the guides for the labeling strips of the 15" Touch/Key version. ① Guide for labeling strips F1, F3 ... F15 ② Guide for labeling strips F2, F4 ... F16 ③...
  • Page 31: Mounting The Device

    Installing and connecting the device 3.2 Mounting the device Mounting the device 3.2.1 Notes on installation Before installing the device, please ensure that the installation location complies with the following: WARNING Risk of fire The device is classified for use as "Open Type" according to UL508 in the Industrial Control Equipment sector.
  • Page 32: Position Of The Mounting Clamps Or Latch Fasteners

    Installing and connecting the device 3.2 Mounting the device 3.2.2 Position of the mounting clamps or latch fasteners You can mount the device as follows: ● With 12 mounting clamps, included in the scope of delivery ● With 6 latch fasteners, available as accessories. To ensure that the device has the correct degree of protection, the mounting clamps/latch fasteners must be affixed in the positions shown in the following diagrams.
  • Page 33: Mounting The Device With Mounting Clamps

    Installing and connecting the device 3.2 Mounting the device 3.2.3 Mounting the device with mounting clamps Requirement ● All packaging components and protective films have been removed from the device. ● The mounting clamps included in the accessory kit are ready to hand. Procedure Note If the mounting seal is damaged or protrudes over the device, the degree of protection is not...
  • Page 34: Mounting With Latch Fasteners

    Installing and connecting the device 3.2 Mounting the device 3.2.4 Mounting with latch fasteners Requirement ● All packaging components and protective films have been removed from the device. ● The latch fasteners included in the accessory kit are ready to hand. Procedure Note If the mounting seal is damaged or protrudes over the device, the degree of protection is not...
  • Page 35: Connecting The Device

    Installing and connecting the device 3.3 Connecting the device Connecting the device 3.3.1 Overview Connection diagram for standard monitor version Connection diagram for standard touch version Connection diagram for extended versions Industrial Flat Panel IFP1500, IFP1900, IFP2200 Operating Instructions, 09/2012, A5E31298376-AA...
  • Page 36: Notes On Connection

    Installing and connecting the device 3.3 Connecting the device 3.3.2 Notes on connection Requirement ● The device has been installed according to the information provided in these operating instructions. ● During operation, ensure that all the lines used comply with the specifications in the section Accessories (Page 15).
  • Page 37: Connecting The Protective Earth

    Installing and connecting the device 3.3 Connecting the device 3.3.3 Connecting the protective earth The protective conductor discharges dangerous currents, triggering a surge protection switch. The protective conductor also discharges any interference transmitted from external power supply cables, signal cables or cables to the I/O devices. The relevant symbol on the device identifies the terminal for the protective conductor.
  • Page 38: Connecting The Power Supply

    Installing and connecting the device 3.3 Connecting the device 3.3.4 Connecting the power supply Depending on the device version, you can operate the device with the following voltage: ● Standard monitor and standard touch versions: 24 V DC ● Extended versions: 24 V DC or 100 to 240 V AC Note To turn off the device completely, disconnect it from the power supply.
  • Page 39 Installing and connecting the device 3.3 Connecting the device Procedure 1. Ensure that the cable ends of the power supply lines are fitted with end sleeves. 2. Fasten the end of a connecting cable L+ and a connecting cable M with the supplied power supply terminal.
  • Page 40: Connecting An Ac Power Supply

    Installing and connecting the device 3.3 Connecting the device 3.3.4.2 Connecting an AC power supply Note before connecting NOTICE Damage to the device in ungrounded supply systems The device features a safety-certified power cable. Connect the device only to a grounding socket.
  • Page 41 Installing and connecting the device 3.3 Connecting the device For USA and Canada: A CSA or UL-listed power supply cable must be used in the United States and Canada. 120 V power supply Use a flexible cable with the following characteristics: ●...
  • Page 42: Connecting The Device To A Pc

    Installing and connecting the device 3.3 Connecting the device 3.3.5 Connecting the device to a PC 3.3.5.1 Standard version Procedure 1. Connect the Flat Panel and the PC using a DVI or DisplayPort line. 2. If using a Touch version, also connect the device and the PC with a USB line.
  • Page 43: Connecting A Usb Device

    Installing and connecting the device 3.3 Connecting the device 3.3.6 Connecting a USB device Below are examples of devices you can connect to the USB interfaces of the device: ● External mouse ● External keyboard ● USB memory stick Note when connecting Note Use of USB devices ...
  • Page 44: Securing The Cables

    Installing and connecting the device 3.3 Connecting the device 3.3.7 Securing the cables Use cable ties to secure the connected cables to the selected fixing elements for strain relief. Make sure that the cables are not crushed by the cable tie. The figure below shows the fixing elements of the IFP1500 Touch.
  • Page 45: Commissioning The Device

    Commissioning the device If you want to operate the device exclusively as monitor, you do not need to commission the device. If you want to use the IPC Wizard functions (Page 53), you do need to commission the device. Prerequisites ●...
  • Page 46 Commissioning the device 5. Follow the instructions. The SIMATC IPC Wizard recognizes the available hardware components and installs the respective software. This procedure may take a few minutes. When all software components have been successfully installed, the following dialog is displayed: 6.
  • Page 47: Operating The Device

    Operating the device Overview Operator input options Depending on your device and the connected I/O devices, the following operating options are available: ● Touch screen You can touch operator controls with a finger or touch pen (see section Accessories (Page 15).) ●...
  • Page 48: Operating The Touch Screen

    Operating the device 5.2 Operating the touch screen External keyboard Note The keyboard layout has been set to "English/USA international". If you use a keyboard with a layout other than the "English/USA international" layout, the key codes of the internal and external keyboards might no longer correspond.
  • Page 49: Using The On-Screen Keyboard

    Operating the device 5.3 Using the on-screen keyboard Using the on-screen keyboard You can operate the device by means of a virtual screen keyboard. You can use it to enter the characters directly on the touch screen or with the mouse. The virtual on-screen keyboard "HMITouchInput"...
  • Page 50: Operating A Touch/Key Device

    Operating the device 5.4 Operating a Touch/Key device Operating a Touch/Key device This section describes the keyboard assignment of the device in the delivery state. The assignment of the keys, including the function keys and control of the LEDs, is specified by means of the SIMATIC IPC KeyTools which is installed with the SIMATIC IPC Wizard.
  • Page 51 Operating the device 5.4 Operating a Touch/Key device Control keys The following table describes the control keys and their associated functions. With keyboard shortcuts, hold the first key down. Then press the second button. Key or keyboard Function shortcut Switch between upper and lower case: LED on: Upper case ...
  • Page 52 Operating the device 5.4 Operating a Touch/Key device Cursor keys Key or keyboard Function shortcut Moves the cursor, selection or a controller in the specified direction. Moves the cursor or selection one page up. Moves the cursor or selection one page down. Moves the cursor to the start of the first screen.
  • Page 53: Ipc Wizard Functions

    IPC Wizard functions Overview With the SIMATIC IPC Wizard, you install the following software and drivers with extended functions for the devices: ● KeyTools ● Phonekeypad ● UPDD (Universal Pointing Device Driver) ● Panel PC Tools – SetBrightness – BbcScreenSaver ●...
  • Page 54: Standard Calibration

    IPC Wizard functions 6.3 Standard calibration Standard calibration Procedure 1. Select "Start > Programs > UPDD > Settings". The "UPDD Console" dialog box opens. Select the touch controller of the device you want to calibrate in the header of the dialog. 2.
  • Page 55: Extended Calibration

    IPC Wizard functions 6.4 Extended calibration Extended calibration Procedure 1. Select "Start > Programs > UPDD > Settings". The "UPDD Console" dialog box opens. Select the touch controller of the device you want to calibrate in the header of the dialog. 2.
  • Page 56: Extended Touch Touch Functionality

    IPC Wizard functions 6.5 Extended Touch touch functionality Extended Touch touch functionality Procedure 1. Select "Start > Programs > UPDD > Settings". The "UPDD Console" dialog box opens. Select the touch controller of the device you want to activate the extended touch functions for in the header of the dialog.
  • Page 57: Maintaining And Servicing Your Device

    Maintaining and servicing your device Cleaning the device Scope of maintenance When working in areas where there is dust that may be hazardous to functionality, the device must be operated in a control cabinet with a heat exchanger or with suitable supply air.
  • Page 58: Spare Parts And Repairs

    Siemensstr. 2 90766 Fürth Germany See also Spare parts and repairs (http://support.automation.siemens.com/WW/view/en/16611927) Recycling and disposal The devices described in these operating instructions can be recycled thanks to their low level of pollutants. Contact a certified disposal service company for environmentally sound recycling and disposal of your old devices.
  • Page 59: Technical Information

    (Guidelines for Explosion Protection) EC Declaration of Conformity The EC Declarations of Conformity are available to the relevant authorities at the following address: Siemens Aktiengesellschaft Industry Sector I IA AS FA WF AMB PO Box 1963 D-92209 Amberg, Germany You can download information on the EC Declaration of Conformity, here under the keyword "Declaration of Conformity":...
  • Page 60 Ex tc IIIC T 70 °C Dc IP65 x: Temperature values, see EC design examination certificate The EC type examination certificates are available on the Internet at: Technical Support (http://www.siemens.de/automation/csi_en_WW) Industrial Flat Panel IFP1500, IFP1900, IFP2200 Operating Instructions, 09/2012, A5E31298376-AA...
  • Page 61: Australia, Class A

    Technical information 8.1 Certificates and approvals The table below describes the test numbers of the HMI device classes: Manufacturer site HMI device class Test number Siemens AG Comfort Panel, ITC, IFP DEKRA11ATEX0005X Industry Sector Werner-von-Siemens-Straße 50 D-92209 Amberg, Germany FCC and Canada...
  • Page 62: Korea

    Technical information 8.2 ESD guideline 8.1.2 Korea KOREA This product meets the requirements of Korean certification. This product satisfies the requirement of the Korean Certification (KC Mark). 이 기기는 업무용(A급) 전자파 적합기기로서 판매자 또는 사용자는 이 점을 주의하시기 바라며 가정 외의 지역에서 사용하는 것을 목적으로 합니다. Marine approvals Acceptance procedures for shipping and offshore applications: ●...
  • Page 63 Technical information 8.2 ESD guideline Electrostatic sensitive devices can be labeled with an appropriate symbol. NOTICE Damage to ESD from touch Electrostatic sensitive devices, ESD, can be destroyed by voltages which are far below the human perception limit. If you touch a component or electrical connections of a module without discharging any electrostatic energy, these voltages may arise.
  • Page 64 Technical information 8.2 ESD guideline NOTICE Grounding measures There is no equipotential bonding without grounding. An electrostatic charge is not discharged and may damage the ESD. Protect yourself against discharge of static electricity. When working with electrostatic sensitive devices, make sure that the person and the workplace are properly grounded. Protective measures against discharge of static electricity ●...
  • Page 65: Dimension Drawings

    Technical information 8.3 Dimension drawings Dimension drawings 8.3.1 Dimension drawing of the IFP1500 Monitor and Touch Industrial Flat Panel IFP1500, IFP1900, IFP2200 Operating Instructions, 09/2012, A5E31298376-AA...
  • Page 66: Dimension Drawing Of The Ifp1900 Monitor And Touch

    Technical information 8.3 Dimension drawings 8.3.2 Dimension drawing of the IFP1900 Monitor and Touch Industrial Flat Panel IFP1500, IFP1900, IFP2200 Operating Instructions, 09/2012, A5E31298376-AA...
  • Page 67: Dimension Drawing Of The Ifp2200 Monitor And Touch

    Technical information 8.3 Dimension drawings 8.3.3 Dimension drawing of the IFP2200 Monitor and Touch Industrial Flat Panel IFP1500, IFP1900, IFP2200 Operating Instructions, 09/2012, A5E31298376-AA...
  • Page 68: Dimension Drawing Of The Ifp1500 Touch/Key

    Technical information 8.3 Dimension drawings 8.3.4 Dimension drawing of the IFP1500 Touch/Key Industrial Flat Panel IFP1500, IFP1900, IFP2200 Operating Instructions, 09/2012, A5E31298376-AA...
  • Page 69: Dimensions For Labeling Strips

    This section contains the dimensions of the labeling strips for 15" widescreen devices. Labeling strip templates are available in a Word document on the Internet at: Labeling strips for 15" widescreen (http://support.automation.siemens.com/DE/view/en/59000814) Industrial Flat Panel IFP1500, IFP1900, IFP2200 Operating Instructions, 09/2012, A5E31298376-AA...
  • Page 70: Rating Plate

    Technical information 8.4 Rating plate Rating plate The rating plate includes information that clearly identifies your device. You need this information when you contact Customer Support. ① Order number ② Serial number ③ Production version Technical specifications 8.5.1 General technical specifications Weight IFP1500 IFP1900...
  • Page 71 Technical information 8.5 Technical specifications Input device Monitor standard Touch standard Touch Extended IFP1500 Touch/Key versions versions versions Keyboard On-screen keyboard On-screen On-screen   keyboard keyboard Externally via USB Externally via USB   Device keys  Analog resistive touch screen Function keys Labeling strips...
  • Page 72: Ambient Conditions

    Technical information 8.5 Technical specifications AC power supply Extended versions Rated voltage 230 V AC Permitted voltage range 100 ... 240 V Rated current 200 mA Inrush current I 0.5 A Power consumption, typical 40 W Minimum time between two transients 50 s Internal protection Electronic...
  • Page 73: Operating Conditions

    Technical information 8.5 Technical specifications 8.5.2.2 Operating conditions Mechanical and climatic conditions of use The device is designed for use in locations protected from the effects of the weather. The conditions of use meet the requirements for DIN IEC 60721-3-3: ●...
  • Page 74 Technical information 8.5 Technical specifications Testing mechanical ambient conditions The table below provides information on the type and scope of tests for mechanical ambient conditions. Tested for Test standard Comments Vibrations Vibration test in accordance Type of vibration: with IEC 60068, part 2–6 Frequency cycles at a rate of change of 1 (sinusoidal) octave/minute.
  • Page 75: Information On Insulation Tests, Protection Class And Degree Of Protection

    Technical information 8.6 Interface description 8.5.2.3 Information on insulation tests, protection class and degree of protection Test voltages Insulation strength is demonstrated in the type test with the following test voltages in accordance with IEC 61131-2: Circuits with a nominal voltage of U to other Test voltage circuits or ground...
  • Page 76: Dvi-D Interface

    Technical information 8.6 Interface description 8.6.2 DVI-D interface DVI-D interface Pin no. Abbreviation Signal TX2N TDMS data 2- TX2P TDMS data 2+ TMDS data shield 2, ground Not assigned Not assigned DDC CLK DDC clock DDC CLK DDC data Not assigned TX1N TDMS data 1- TX1P...
  • Page 77: Displayport

    Technical information 8.6 Interface description 8.6.3 DisplayPort DisplayPort interface Pin no. Abbreviation Meaning Input/output ML_Lane3- DP data 3- Input Ground ML_Lane3+ DP data 3+ Input ML_Lane2- DP data 2- Input Ground ML_Lane2+ DP data 2+ Input ML_Lane1- DP data 1- Input Ground ML_Lane1+...
  • Page 78: Usb Interface, Type B

    Technical information 8.6 Interface description 8.6.4 USB interface, Type B USB interface, Type B Pin No. Abbreviation Signal + 5 V (fused) - Data Data channel + Data Data channel Ground 8.6.5 USB hub, Type A USB port Pin No. Short name Signal + 5 V (fused)
  • Page 79: Technical Support

    Service and support You can find additional information and support for the products described on the Internet at the following addresses: ● Technical support (http://www.siemens.de/automation/csi_en_WW) ● Support request form (http://www.siemens.com/automation/support-request) ● After-sales information system for SIMATIC PC / PG (http://www.siemens.com/asis) ●...
  • Page 80 Technical Support A.1 Service and support Industrial Flat Panel IFP1500, IFP1900, IFP2200 Operating Instructions, 09/2012, A5E31298376-AA...
  • Page 81: List Of Abbreviations

    List of abbreviations ANSI American National Standards Institute ASCII American Standard Code for Information Interchange Width Backlight Inverter BIOS Basic Input Output System CD-ROM Compact Disc – Read Only Memory Central Processing Unit Direct Current DHCP Dynamic Host Configuration Protocol Domain Name Service Distributed I/O Data Source Name...
  • Page 82 List of abbreviations Industrial Flat Panel IFP1500, IFP1900, IFP2200 Operating Instructions, 09/2012, A5E31298376-AA...
  • Page 83: Glossary

    Glossary Application An application is a program which is put directly on the operating system MS-DOS or windows. An application on the PC/PG, for example, is STEP 7. Booting Start or restart of the computer. During the boot sequence, the operating system is loaded from the system data carrier into RAM.
  • Page 84 Glossary Module Modules are plug-in units for PLCs, programming devices or PCs. Modules exist, for example, as central modules, power-ons, or as mass storage. Plug and play Through plug and play, the computer configures itself automatically to be able to communicate with peripheral devices, e.g.
  • Page 85: Index

    Index CTRL key, 51 Cursor key, 52 Cursor keys, 52 Abbreviations, 81 AC power supply Technical specifications, 72 ACK key, 51 DC power supply Acknowledge key, 51 Technical specifications, 71 Alphanumeric keys, 50 Degree of protection, 28 ALT key, 51 Protection against ingress of solid foreign Ambient conditions bodies, 75...
  • Page 86 Index Infotext Marine approval, 62 Key, 51 Mechanical Input device Storage conditions, 72 Technical specifications, 71 Transport conditions, 72 Instructions Mounting General, 19 Horizontal mounting, 26 Insulation test Notes on installation, 31 Test voltage, 75 Vertical, 26 Interface with latch fasteners, 34 24 V DC, 75 with mounting clamps, 33 DisplayPort, 77...
  • Page 87 Index Radiation, 18 UL approval, 60 High frequency radiation, 18 Unintentional action, 47 Radio interference, 19 USA, 41 Rated load USB device Interface, 43 Connecting, 43 Regional information, 40 Conditions, 73 In residential areas, 19 Industrial, 19 With additional measures, 73 Safety Certificates, 59 Standards, 59...
  • Page 88 Index Industrial Flat Panel IFP1500, IFP1900, IFP2200 Operating Instructions, 09/2012, A5E31298376-AA...