● Strictly observe utmost cleanliness. The Sytronix system must be installed
● Do not use cotton waste or linty cloths for cleaning.
● Use suitable liquid cleaning agents to remove lubricants and other difficult-
7.3.2

Compatibility with foreign substances

All drives and controls from Bosch Rexroth are developed and manufactured
according to the state of the art.
However, since it is impossible to pursue the continuing further development
of all substances with which the drives and controls may get into contact (e.g.
lubricants in machine tools), reactions with the materials used by us cannot be
ruled out in any case.
For this reason you have to carry out a compatibility test with new lubricants,
cleaning agents, etc. and our housings/materials.
7.3.3

Installation position and orientation of the motor-pump unit

The installation orientation (orientation of the pump/motor shaft end vertical,
horizontal, etc.) and the installation position (pump/motor in relation to tank)
of the Sytronix system essentially determine the procedures during installation
and commissioning (such as for filling the axial piston unit).
Note that you can expect certain installation positions to affect the control
behavior or the adjustment feature. Because of gravity, dead weight and case
pressure, minor characteristic curve offsets and changes in actuating time may
occur.
A detailed description of the installation and mounting conditions as well as
the installation of the motor-pump unit can be found in the operating instruc-
tions for MPA02, R911387041.
Special attention has to be paid to the connection and wiring of the motor
power cable, of the encoder and the cooling fan.
Fig. 7: Installation orientations
The motor-pump group can be foot- or flange-mounted. Permissible installation
orientations according to EN 60037-7 IM B3, IM B5 and IM V1. A vertical instal-
lation orientation IM V3 (motor under pump) is not permitted.
RE 62312-B, 03.2022
Mechanical installation of the motor-pump unit
without any contamination. Contamination of the hydraulic fluid can signifi-
cantly affect the service life of the Sytronix system.
to-remove dirt. Cleaning agents must not penetrate the hydraulic system.
B3
B5
Sytronix SvP 7030 IMC
V1
mpa01-0008el