TOOLS


The fixture controlled by the Z-Wave In-Wall Smart Switch must not exceed 960W (incandescent); 1800W (15A) Resistive or 1/2 HP Motor. The switch is designed only for use with permanently installed fixtures.

FEATURES

  • Turn ON/OFF manually or remotely via the Z-Wave controller
  • Can be added in multiple groups and scenes
  • May be used in single-pole installation or with up to two Honeywell add-on switches in 3-way or 4-way wiring configurations
  • Compatible with all incandescent and CFL/LED bulbs
  • Auto line/load detection
  • Interchangeable paddle switch — white & light almond paddle in package
  • Uses a standard, decorative-size wallplate for single-gang installations (wallplate not included)
  • Blue LED indicates switch location in a dark room
  • Z-Wave certified for simple pairing and integrated home automation
  • Screw terminal installation — requires wiring connections for line (hot), load, neutral and ground. Traveler wire required for 3-way or 4-way installation
  • This Z-Wave device has advanced features that allow you to customize your experience. These features can only be adjusted by a Z-Wave enabled controller that supports the Z-Wave configuration command class. For a complete list of adjustable configurations, visit www.honeywellelectricalaccessories.com

Overview

INSTALLATION

INSTALLATION - Step 1

Insert wires into holes, do not wrap wires around screws.
Do not remove screws.
INSTALLATION - Step 2 INSTALLATION - Step 3

CONNECTION

CONNECTION

CONNECTING YOUR DEVICE TO A Z-WAVE NETWORK

  1. Follow the instructions for your Z-Wave certified controller to add a device to the Z-Wave network.
  2. Once the controller is ready to add your device, press and release the top or bottom of the wireless smart switch (rocker) to add it in the network. If prompted by the controller to enter the S2 security code, refer to the QR code/security number on the back of the box, or the QR code label on the product.

Now you have complete control to turn your fixture ON/OFF according to groups, scenes, schedules and interactive automations programmed by your controller. If your Z-Wave certified controller features remote access, you can now control your fixture from your mobile devices.

REMOVING AND RESETTING THE DEVICE

  1. Follow the instructions for your Z-Wave certified controller to remove a device from the Z-Wave network.
  2. Once the controller is ready to remove your device, press and release the top or bottom of the wireless smart switch (rocker) to remove it from the network.

RETURNING SWITCH TO FACTORY DEFAULTS
Quickly press ON (top) button 3 times, then, immediately press the OFF (bottom) button 3 times. The LED will flash ON/OFF 5 times when completed successfully.
Note: This should only be used in the event your network's primary controller is missing or otherwise inoperable.

CUSTOMIZATION

CUSTOMIZATION

CHANGING THE COLOR OF THE PADDLE
This step is optional. Before installation, you may want to change the color of the paddle to match your wallplate or décor.

  1. Lift the air gap tab at the base of the paddle.
  2. Push side tabs in on one side and then the other to release paddle. Lift the cover up and off.
  3. Simply put the new paddle onto the switch by inserting the air gap and side tabs and snapping securely into place. Once this step has been completed.


This device supports Association Command Class (3 Groups)

  • Association Group 1 supports Lifeline, Binary Switch Report
  • Association Group 2 supports Basic Set and is controlled by pressing the ON or OFF button with the local load
  • Association Group 3 supports Basic Set and is controlled by double pressing the ON or OFF button
  • Each Association Group supports 5 total nodes


SHOCK HAZARD

Turn OFF the power to the branch circuit for the switch and lighting fixture at the service panel. All wiring connections must be made with the POWER OFF to avoid personal injury and/or damage to the switch. This device is intended for installation in accordance with the National Electric Code and local regulations in the United States, or the Canadian Electrical Code and local regulations in Canada. If you are unsure or uncomfortable about performing this installation consult a qualified electrician.

MULTI-SWITCH WIRING
The Honeywell Add-on switch is required for Multi-Switch 3-way or 4-way installations. Connecting the traveler terminal of this switch to a standard, non-Honeywell switch will cause damage or result in improper function. If this switch is a part of a 3-way or 4-way multi-switch installation, do not connect the traveler wire or apply power until Honeywell Add-on switches are correctly installed. For more information on 3-Way or 4-Way installations, view the manual or quick-start guide that comes with the Honeywell Add-on switch.

SINGLE-SWITCH WIRING
Before you start; you may wish to change the paddle color to match your wallplate or decor. Please proceed to Section 5.

  1. Shut off power to the circuit at circuit breaker or fuse box.

    Verify power is OFF to switch box before continuing.
  2. Remove wallplate.
  3. Remove the switch mounting screws.
  4. Carefully remove the switch from the switch box. DO NOT disconnect the wires.
  5. There are up to five screw terminals on the switch; these are marked
    1. GROUND — Green/Bare

    2. LINE OR LOAD — Black (connected to power or lighting)

    3. LINE OR LOAD — Black (connected to power or lighting)

    4. TRAVELER — Red/Other (only in 3-way installations)

    5. NEUTRAL — White
      Match these screw terminals to the wires connected to the existing switch.

  6. Disconnect the wires from the existing switch. Be careful to label wires according to the previous terminal connection.

OBSERVE IMPORTANT WIRING INFORMATION

This switch is rated for and intended to only be used with copper wire.

WIRE GAUGE REQUIREMENTS
Use 14 AWG or larger wires suitable for at least 80°C for supplying Line (HOT), Load, Neutral, Ground and Traveler connections.

WIRE STRIP LENGTH

  1. For attachment to screw terminals: strip insulation 1" (25mm)
    For attachment using the enclosure's holes: strip insulation 5/8" (16mm)
    UL specifies that the tightening torque for the screws is 14 Kgf-cm (12 lbf-in).
  2. Connect the green or bare copper ground wire to the GROUND terminal.
  3. Connect the black wire that goes to the light to either LINE/LOAD terminal.
  4. Connect the white wire to the neutral terminal (use a jumper wire if needed).
    Note: The Traveler terminal is only used for 3-way or 4-way wiring and should remain insulated if the switch is being installed in a single pole installation (one switch & one load).

BASIC OPERATION
The connected light can be turned ON/OFF in two ways:

  • Manually from the front panel of the In-Wall Switch.
  • Remotely with a Z-Wave Controller.

MANUAL CONTROL
The front panel rocker switch allows the user to turn ON/OFF the connected fixture.

  • To turn the connected fixture ON: press and release the top of the rocker.
  • To turn the connected fixture OFF: press and release the bottom of the rocker.

CYCLE LED LIGHT
The LED below the switch acts as a guide light or status indicator.
How to cycle through options: Press up three times and down once quickly.

  1. LED is ON when the load is off (guide light in the dark) (default).
  2. LED is ON when the load is ON (indicates the switch is ON).
  3. LED is always OFF.
  4. LED is always ON (illuminates switch in the dark).

Z-WAVE INTEROPERABILITY

This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. Allnon-battery operated nodes within the network willact as repeaters regardless of vendor to increase reliability of the network.

SPECIFICATIONS

ZW4008
Power: 120VAC, 60Hz.
Signal (Frequency): 908.4/916 MHz
Maximum Loads: 960W, incandescent, 1/2HP Motor or 1800W (15A) resistive
Range: Up to 150ft. line of sight between the wireless controller and the closest Z-Wave receiver module.
Operating Temperature Range: 32-104°F (0-40°C)
Type 1 enclosure, independently mounted (vertical position only), operating control: type 1.c action, pollution degree (2), impulse voltage (2500V), software class A
For indoor use only.
Specifications subject to change without notice due to continuing product improvement.

WARRANTY

Jasco Products warrants this product to be free from manufacturing defects for two years from the original date of consumer purchase. This warranty is limited to the repair or replacement of this product only and does not extend to consequential or incidental damage to other products that may be used with this product. This warranty is in lieu of all other warranties, expressed or implied. Some states do not allow limitations on how long an implied warranty lasts or permit the exclusion or limitation of incidental or consequential damage, so the above limitations may not apply to you. This warranty gives you specific rights and you may also have other rights which vary from state to state. Please contact Customer Service at 1-855-698-8324 between 7AM – 8PM CST or via www.byjasco.com if the unit should prove defective within the warranty period.


Z-Wave ® Certified Wireless lighting Control

Documents / Resources

References

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Need Assistance?

Do you have a question about the ZW4008 that isn't answered in the manual? Leave your question here.

Error while submitting your question. Please, reload page and try again.

Thank you! Your question has been received!

Table of Contents