Fujitsu Airstage Series Operation Manual
Fujitsu Airstage Series Operation Manual

Fujitsu Airstage Series Operation Manual

Wall mounted type
Hide thumbs Also See for Airstage Series:

Quick Links

OPERATION MANUAL
MODEL:
* Please write down the model name.
(Refer to the rating label.)
* Veuillez écrire le nom du modèle.
(Consultez l'étiquette des spécifi cations.)
* Anote el nombre de modelo.
(Consulte la etiqueta de califi cación).
PART No. 9387602098-02
AIR CONDITIONER (Wall Mounted type)
Before using this product, read these instructions thoroughly
and keep this manual for future reference.
CLIMATISEUR (Type à montage mural)
Avant d'utiliser ce produit, veuillez lire attentivement ces
instructions. Conservez ce manuel pour référence future.
MANUAL DE FUNCIONAMIENTO
ACONDICIONADOR DE AIRE (Tipo montado en pared)
Antes de utilizar el producto, lea estas instrucciones detenida-
mente y conserve este manual para consultarlo en el futuro.
OPERATION MANUAL
MODE D'EMPLOI
Table of Contents
loading

Summary of Contents for Fujitsu Airstage Series

  • Page 1 OPERATION MANUAL OPERATION MANUAL AIR CONDITIONER (Wall Mounted type) Before using this product, read these instructions thoroughly and keep this manual for future reference. MODE D’EMPLOI CLIMATISEUR (Type à montage mural) Avant d'utiliser ce produit, veuillez lire attentivement ces instructions. Conservez ce manuel pour référence future. MANUAL DE FUNCIONAMIENTO ACONDICIONADOR DE AIRE (Tipo montado en pared) Antes de utilizar el producto, lea estas instrucciones detenida-...
  • Page 2: Table Of Contents

    [Original instructions] Contents WARNING 1. SAFETY PRECAUTIONS .......... 1 • This product contains no user-serviceable parts. Always consult authorized service personnel for 2. PREPARATION ............2 repairing, installation, and relocation of this product. 3. NAME OF PARTS ............. 2 Improper installation or handling will cause leakage, electric shock, or fi...
  • Page 3: Preparation

    3. NAME OF PARTS CAUTION • Do not place any other electrical products or household belongings under this product. Dripping CAUTION condensation from this product might get them wet, For appropriate signal transmission between the remote and may cause damage or malfunction of your controller and the indoor unit, keep the signal receiver property.
  • Page 4: Remote Controller

    3.2. Remote controller CAUTION • To prevent malfunction or damage of the remote When you use the optional remote controller, the appearance controller: and the operation procedure may diff er. - Place remote controller at where will not be For details, please refer to the operation manual of each remote exposed to direct sunlight or excessive heat.
  • Page 5: Inserting Batteries

    3.3. Inserting batteries Battery type: R03/LR03/AAA x 2 For Powerful operation ....Refer to page 8. Activates or deactivates the Powerful operation. RESET For Airfl ow settings ....... Refer to page 5. Controls the fan speed. Pull the cover in the direction of the arrow and open it Sets the automatic Swing operation.
  • Page 6: Basic Operations

    ■ Airfl ow direction range 4. BASIC OPERATIONS Vertical airfl ow direction ■ 3 steps to start operation 1 ⇄ 2 ⇄ 3 ⇄ 4 ⇄ 5 ⇄ 6 Change by 1. Press to start or stop the operation. Swing operation by 2.
  • Page 7: Weekly Timer

    ■ Examples of Weekly timer 6.1. Weekly timer Example 1 ■ Setting details 7:00 9:00 11:00 17:00 23:00 1. Select Weekly timer in step 2 of "Timer setting procedure". Monday Program Program Program Program 2. Press to select the program number and the Friday Off...
  • Page 8: Energy Saving Operations

    NOTES: 6.4. Sleep timer • The following operations will override the Energy Saving program. - Sleep timer operation 1. Select Sleep timer in step 2 of "Timer setting procedure". - Min. Heat operation • The Energy Saving program may not work when the room 2.
  • Page 9: Other Operations

    8. OTHER OPERATIONS 9. WIRELESS LAN CONTROL This operation manual describes only the setting procedure of the 8.1. Powerful operation remote controller. For how to operate the mobile app, refer to the operation manual of the mobile app. In the Powerful operation, the air conditioner will operate at maximum power and strong airfl...
  • Page 10: Usage Precautions

    9.1. Usage precautions Radio wave and security precautions When you use a wireless LAN, there are precautions that you Usage precautions for wireless LAN control must follow in relation to radio waves, personal information, and so on. To use this product correctly, be sure to read the following precautions and the operation manual of the wireless LAN equipment you are using.
  • Page 11: Setting To Use Wireless Lan Control

    ■ Others For reference ● Use this product as regular wireless LAN equipment. Setting procedure of the remote controller • Do not use this product in hospitals or in/near locations with medical equipment. NOTES: If you do not press any buttons of the remote controller for 60 seconds, the remote controller display will return to the original •...
  • Page 12: Settings On Installation

    3. Open the W-LAN adapter cover until it snaps. Initialization (reset) Initialize (reset) this product in the following situations: • Changing the wireless router • Disposing this product • Transferring this product to a third party Unregister the air conditioner Unregister the air conditioner by using the mobile app.
  • Page 13: Cleaning And Care

    11. CLEANING AND CARE Cleaning air fi lter 1. Open the intake grille. CAUTION • Before cleaning this product, be sure to turn it off and disconnect all the power supply. • Before starting operation, make sure that the intake grille has been shut completely.
  • Page 14: General Information

    8. Set the new or washed air cleaning fi lters into the air After extended non-use of the unit cleaning fi lter frames. If you have shut down the indoor unit for 1 month or more, perform the NOTES: Use the Apple-catechin fi lter as soon as possible after opening Fan mode operation for half a day to dry the internal parts thoroughly the package.
  • Page 15: Optional Parts

    ■ Indoor unit temperature and humidity range Does not operate at all. Permissible ranges of temperature and humidity are as follows: □ Has there been a power outage? In this case, the unit restarts automatically after the power supply Indoor temperature Cooling/Dry [°F (°C)] 64 to 89 (18 to 32) is resumed.
  • Page 16 ■ State of indicator lamps Smell coming from the unit. : The instruction is relating to the wireless LAN control. □ The air conditioner may absorb various smells generated from interior textile, furniture, or cigarette smoke. These smells may be Lighting pattern: Off...