Quick Links

Please read this manual carefully before use
Please keep this manual properly for reference.
(please read before use)
Symbol interpretation
Indicates the act that must be forbidden
Indicates the act that must be carried out
Indicates the matter which must be paid attention to
Caution
Our company will not bear any responsibility for incorrect installation and use of
this water heater!
Note:
Failure to follow this manual means the risk of accident, property loss and personal injury.
The water heater must be repaired or maintained by qualified professional personnel.
Improper operation may cause serious personal injury or property loss.
Technical parameter
Model
EI39G1M(W) EI39G1M(S)
Rated power-Rated
W-A
current
3950-16.5
AC 240 V
Rated Frequency
50 Hz
Waterproof Grade
IP25
Rated Pressure
0 MPa
Maximum water-out
o
50 C
temperature
Minimum inlet pressure
0.02MPa
Maximum inlet pressure
0.6MPa
Start flow
1.5L/min
Outline dimension
360 mm*200 mm*85 mm
Net weight
1.85kg
Note:The allowable error range of the net weight is ±10%.
heater
(Set)
EI39G1M(W)
1
1
EI39G1M(S)
Installation guide
Precautions for installation
.
1
The load-bearing wall for installing the water heater should be able to bear twice the weight of the water
heater filled with water.
.
2
The water heater should be installed indoors and in a non-icing place, with pipes arranged centrally.The hot
water outlet should not be too far away from the hot water use point. If the distance exceeds 2m,the hot water
pipe should be insulated to reduce heat loss.
3
.
The water heater should be installed in a place that is convenient for use and maintenance and has a sewer
to ensure that surrounding or lower facilities cannot be damaged when water heater or water pipe leaks. Please
do not install the water heater in a place that can be sprayed directly or is prone to icing.
4. Because of the high power of this water heater, before installing the water heater, please carefully check
whether the ammeter and power wire diameters (2.5mm
voltage requirements of this water heater. If necessary, please ask a professional electrician to check the circuit.
5. Do not connect the water-in and water-out pipes reversely; Under no circumstances should the outlet be
blocked.
6. To ensure safety, the water heater should use the standard single-phase bipolar air switch or circuit breaker
(in the case of circuit breaking, the open distance of all contacts should be at least 3mm so as to reliably cut off
the connection with the external power supply during maintenance), and be earthed reliably, with the earthing
resistance of the household earth wire less than 4Ω. Because the water heater requires a large current,the
incoming power supply of the water heater must be directly connected with the air switch, and the power plug
should not be used.
Instantaneous Water Heater
Operation Manual
Model:
EI39G1M(W)
EI39G1M(S)
0040510390
V
One dimensional code 60mm*10mm
1
Introduction to components
Crimping
board
Temperature
controller
Heating
element
Stainless
steel circlip
Water-out
temperature
sensor
Water-out
pipe
Three-gear
sprinkler
package
(Set)
(Set)
1
1
1
recommended) and fuse meet the rated current and
2
3
In case of any abnormality or scorching smell of
the water heater, please cut off the power supply
immediately and contact the service center.
Do not touch the power supply with wet hands, so as
to prevent it from getting wet by water. If it is wet by
accident, it must be inspected and confirmed by the
professional personnel appointed by our company
before reuse to prevent electric shock.
In order to ensure safety, the power supply of the water
heater should be reliably earthed, otherwise, it is strictly
prohibited to use the water heater. The test pencil should
be used to determine whether the live wire and the
neutral wire are connected reversely.
Make sure to use an independent power
switch matched with the water heater must be used
This appliance is not to be used for a potable water
supply.
Product specification
Electrical Schematic Diagram
TB: Terminal Block
ER: ELCB Ring
RT2: Water-out Sensor
FL: Flow Sensor
MT: Thermal Cut-Out
HE: Heating Element
7. The test pencil should be used to determine whether the live wire and the neutral wire are connected
reversely.
8. The outlet must not be connected to any tap or fitting other than those specified.
Terminal block
9. The water heater is equipped with the flow control valve. For use safety, the flow control valve should be
Inductor coil
installed on the water-in pipe, and it is strictly forbidden to install the valve at the outlet of the water heater.
10.The water inlet of this appliance shall not be connected to inlet water obtained from any other water heating
Computer
system.
board
11.Metallic / chromed hose and conductive control valve shall not be used!
Installation of whole machine
Flow sensor
1.Remove the front shell
screws and the front shell.
Indicator
board
Water-in pipe
4. Confirm the installation position of the water heater, and drill four φ6X35mm holes on the load-bearing wall
with impact drill, with the spacing as shown in the figure below (it is also allowed to correspondingly locate
the four fixing points by placing the rear shell on the wall). And then, drive four expansion bolts into four holes
respectively, hang up the machine,and fix the machine with screws.
163(mm)
supply.
diameters meet the rated current of the water
Caution
This appliance is not intended for use by persons
(including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge,
unless they have been given supervision or instruction
concerning use of the appliance by a person responsible
for their safety.
Children should be supervised to ensure that they do not
play with the appliance.
Caution
YELLOW
&GREEN
HE
BLACK
RT2
FL
Triac Board
BROWN
COM
MT
BROWN
Control
NO
Display
Board
YELLOW&GREEN
Board
BLUE
COM
BLUE
BLUE
NO
ER
BROWN
2
2.Remove the power cord
3. Install the power cord corresponding to
the live wire, neutral wire and earth wire
plug of the rear shell.
respectively, and fix it by wire nail.
4
hot water
YELLOW
&GREEN
TB
L
loading

Summary of Contents for Haier EI39G1M(W)

  • Page 1 In case of any abnormality or scorching smell of the water heater, please cut off the power supply immediately and contact the service center. Instantaneous Water Heater Do not touch the power supply with wet hands, so as to prevent it from getting wet by water. If it is wet by accident, it must be inspected and confirmed by the Operation Manual professional personnel appointed by our company...
  • Page 2 5. Install the flow control valve on the water-in pipe. 6. Fix the sprinkler pedestal in a suitable position on the wall. installation step figure pedestal model) Adjustable wall Sprinkler bracket Expansion Water saving O-ring rubble gasket screw card Sprinkler hose RAIN MASSAGE COMBO...

This manual is also suitable for:

Ei39g1m(s)