Makita G1100 User Manual
Makita G1100 User Manual

Makita G1100 User Manual

Makita g1100 generator: user guide
Hide thumbs Also See for G1100:
G1100(US)_GU1835 2004.2.6 1:04 PM ページ01
FEDERAL EMISSION COMPONENT DEFECT WARRANTY and CALIFORNIA
EMISSION CONTROL WARRANTY are applicable to only those engines/
generators complied with EPA (Environmental Protection Agency) and CARB
(California Air Resources Board) emission regulations in the U.S.A.
To the engines/generators exported to and used in the countries other than the
U.S.A., warranty service shall be performed by the distributor in each country in
accordance with the standard Makita engine/generator warranty policy as applicable.
To show compliance with California emission regulations, a hangtag has been
provided displaying the Air Index level and durability period of this engine.
The Air Index level defines how clean an engine's exhaust is over a period of
time. A bar graph scaled from "0" (most clean) to "10" (least clean) is used to
show an engine's Air Index level. A lower Air Index level represents cleaner
exhaust from an engine.
The period of time (in hours) that the Air Index level is measured is known as
the durability period. Depending on the size of the engine, a selection of time
periods can be used to measure the Air Index level (see below).
Descriptive Term
Moderate
Intermediate
Extended
Notice : This hangtag must remain on this engine or piece of equipment, and
only be removed by the ultimate purchaser before operation.
WARNING :
The engine exhaust from this product contains
chemicals known to the State of California to
cause cancer, birth defects or other reproductive
harm.
NOTICE
NOTICE
AIR INDEX
Applicable to Emissions Durability Period
-
50 hours (engine from 0 to 65 cc)
125 hours (engine greater than 65 cc)
-
125 hours (engine from 0 to 65 cc)
250 hours (engine greater than 65 cc)
-
300 hours (engine from 0 to 65 cc)
500 hours (engine greater than 65 cc)
US
GB
GB
GB
GB
GB
GB
GB
GB
GB
GB
GB
GB
GB
GB
GB
Table of Contents
loading

Summary of Contents for Makita G1100

  • Page 1 To the engines/generators exported to and used in the countries other than the U.S.A., warranty service shall be performed by the distributor in each country in accordance with the standard Makita engine/generator warranty policy as applicable. To show compliance with California emission regulations, a hangtag has been provided displaying the Air Index level and durability period of this engine.
  • Page 2 EPA regulations during its warranty period. For the components listed under PARTS COVERED, the Makita Factory Service Center or Service Center authorized by MAKITA will, at no cost to you, make the necessary diagnosis, repair, or replacement necessary to ensure that the engine complies with applicable U.S. EPA regulations.
  • Page 3 HOW TO MAKE A CLAIM All repair qualifying under this limited warranty must be performed by a Makita Factory Service Center or Service Center authorized by MAKITA . In the event that any emission-related part is found to be defective during the warranty period, you shall notify Makita Warranty Department at 1-800-4- MAKITA and you will be advised of the appropriate warranty service dealer or service providers where the warranty repair can be performed.
  • Page 4 A list of the Factory Service Center locations and phone numbers is provided below for your convenience. MAKITA , a distributor of small off-road equipment in the U.S., warrants to the owner of 2004 and later engines that the engine has been...
  • Page 5 REPAIR AND REPLACEMENT OF EMISSION-RELATED PARTS It is recommended that only engine replacement parts which have been authorized and approved by MAKITA should be used in the performance of any warranty maintenance or repairs of emission-related parts. These replacement parts will be provided at no charge if the part is still under warranty.
  • Page 6 G1100(US)_GU1835 2004.2.6 1:04 PM ページ06...
  • Page 7: Table Of Contents

    G1100(US)_GU1835 2004.2.6 1:04 PM ページ1 Thank you very much for purchasing a MAKITA GENERATOR. This manual covers operation and maintenance of the MAKITA GENERATOR. Please take a moment to familiarize yourself with the proper operation and maintenance procedures in order to maximize the safe and efficient use of this product.
  • Page 8: Safety Precautions

    The generator has a built-in forced air cooling system, and may become overheated if it is enclosed. If generator has been covered to protect it from the weather during non use, be sure to remove it and keep it well away from the area during generator use.
  • Page 9 The operator may suffer severe electric shock if the generator is wet due to rain or snow. WARNING If wet, wipe and dry it well before starting. Do not pour water directly over the generator, nor wash it with water.
  • Page 10 G1100(US)_GU1835 2004.2.6 1:04 PM ページ4 Symbols and Meanings In accordance with the European requirements (eec Directives),the specified symbols as shown in the following table are used for the products and this instruction manual. Read the operator's instruction manual. Stay clear of the hot surface.
  • Page 11: Components

    G1100(US)_GU1835 2004.2.6 1:04 PM ページ5 2. COMPONENTS (See Fig. 1 1 ) NOTE Please refer to the illustrations on the back page of the front cover or back cover for Fig. 1 1 to 6 6 indicated in the sentence.
  • Page 12: Pre-Operation Checks

    G1100(US)_GU1835 2004.2.6 1:04 PM ページ6 6. DC CIRCUIT BREAKER (See Fig. 2 2 -t t ) DC circuit breakers shut off electric current when the current exceeds its limit or a malfunction occurs in the connected appliance. Check for excessive current consumption or defects in the appliance.
  • Page 13: Operating Procedures

    G1100(US)_GU1835 2004.2.6 1:04 PM ページ7 WARNING Make sure you review each warning in order to prevent fire hazard. Do not refill tank while engine is ■ ■ running or hot. Before filling fuel, turn the engine switch ■ ■ into "...
  • Page 14 (f) Make sure the output lamp is on. This indicates that the generator is properly operating. NOTE Please consult with the Makita factory or authorized service center if the output lamp is turned off during the proper operation. 2. USING ELECTRIC POWER Make sure that the appliance is switched OFF before connecting it to the generator.
  • Page 15 Stop the generator immediately, check the appliance and / or generator for overloading, and have repaired as necessary by Makita factory or authorized service center. (d) Turn on the switch of the appliance. (2) DC APPLICATION (See Fig. 4 4 -t t ) The DC terminal is used only for charging 12 volt batteries.
  • Page 16: Wattage Information

    VOLTAGE DROP IN ELECTRIC EXTENSION CORDS When a long electric extension cord is used to connect an appliance or tool to the generator, a certain amount of voltage drop or loss occurs in the extension cord which reduces the effective voltage available for the appliance or tool.
  • Page 17: Spark Arrester

    G1100(US)_GU1835 2004.2.6 1:04 PM ページ11 7. SPARK ARRESTER In a dry or wooded area, it is recommendable to use the product with a spark arrester. Some areas require the use of a spark arrester. Please check your local laws and regulations before operating your product.
  • Page 18: Maintenance Schedule

    (3) Intake manifold, if applicable (4) Air cleaner elements The maintenance schedule indicated in the table is based on the normal generator operation. Should the generator be operated in extremely dusty condition or in heavier loading condition, the maintenance intervals must be shortened depending on the contamination of oil, clogging of filter elements, wear of parts, and so on.
  • Page 19 G1100(US)_GU1835 2004.2.6 1:04 PM ページ13 Periodic Maintenance Schedule table Maintenance Items CLEAN GENERATOR AND CHECK BOLT AND NUTS CHECK AND REFILL ENGINE OIL CHANGE ENGINE OIL (*Note1) CLEAN SPARK PLUG CLEAN AIR CLEANER REPLACE AIR CLEANER ELEMENT CLEAN FUEL FILTER...
  • Page 20: How-To" Maintenance

    G1100(US)_GU1835 2004.2.6 1:04 PM ページ14 9. "HOW-TO" MAINTENANCE (See Fig. 5 5 ) 1. ENGINE OIL CHANGE (See Fig. 5 5 -q q ) Change engine oil every 50 hours. ■ ■ (For new engine, change oil after 20 hours.) (a) Drain oil by removing the drain plug and the oil filler cap while the engine is warm.
  • Page 21: Troubleshooting

    G1100(US)_GU1835 2004.2.6 1:04 PM ページ15 11. TROUBLESHOOTING When generator engine fails to start after several attempts, or if no electricity is available at the output socket, check the following chart. If your generator still fails to start or generate electricity, contact your nearest Makita factory or authorized service center for further information or corrective procedures.
  • Page 22: Specifications

    G1100(US)_GU1835 2004.2.6 1:04 PM ページ16 12. SPECIFICATIONS MODEL Type Frequency Rated voltage Maximum output Rated output Rated power factor DC output Over current protector Model Type Displacement Fuel Fuel tank capacity L(US-gal) Rated continuous operation [Approx.] hours Starting system Length mm (in.)
  • Page 23: Wiring Diagram

    G1100(US)_GU1835 2004.2.6 1:04 PM ページ17 13.WIRING DIAGRAM G1100 (60Hz-120V) GENERATOR DC coil Wiring color cord : Black LBlu Blk/W : Black/White : Blue Brn/W : Brown/White CONTROL PANEL Brn/W ACreceptacle (230V) NEON LAMP Grn/Y OIL LED Earth (ground) terminal : Light blue...