Panasonic PS-A Quick Start Manual

Panasonic PS-A Quick Start Manual

Pressure sensor

Quick Links

Pressure Sensor
PS-A
Pressure sensor
Built-in amplifi er and compensating circuit

Features

Built-in amplifi er and temperature compensation circuit, no need for circuit design and characteristic adjustment
High accuracy and reliability : overall accuracy ±1.25% FS (Standard), ±2.5% FS (Low-pressure type)
Compact size, space-saving : compatible size for PS type (Standard/Economy, S and M packages)
RoHS compliant

Typical applications

Industrial use : pressure switches and pneumatic components, compressed air pressure measuring devices
Medical use : blood pressure meters, oxygen generator and airbeds
Others : pressure sensing devices for air pressure mediums
Low-pressure type
Water level detection for domestic appliances: washing machines and dishwashers
Air pressure control : cleanrooms and smoking rooms
Medical applications : breathing pressure measuring devices
Ordering information
ADP5
Terminal profile
1
: 1 DIP terminal
: 2
SMD terminal
Product types
Package
(Pressure inlet
hole length)
Terminal
DIP
Pressure
terminal
±100 kPa ADP5100
−100 kPa ADP5110
25 kPa ADP5120
Standard
type
50 kPa ADP5130
(with glass
100 kPa ADP5140
base)
200 kPa ADP5150
500 kPa ADP5160
1, 000 kPa ADP5170
Economy type
40 kPa
(without glass base)
Low pressure type
6 kPa
Standard packing : Carton : 100 pcs.; Case : 1,000 pcs.
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
Rated pressure
Package/Pressure inlet hole
0
:
±100 kPa
0
:
S Package
1
:
−100 kPa
length : 3 mm
2
:
25 kPa
1
:
M Package
3
:
50 kPa
length : 5 mm
4
:
100 kPa
2
:
L Package (Only low pressure type)
5
:
200 kPa
length : 13.5 mm
6
:
500 kPa
3
:
P Package (Only low pressure type)
7
:
1,000 kPa
length : 15.6 mm
A
:
40 kPa
B6
:
6 kPa
(Low pressure type)
Standard type
Standard/Economy type
S Package
(3 mm
0.118
inch)
(5 mm
SMD
DIP
terminal
terminal
ADP5200
ADP5101
ADP5210
ADP5111
ADP5121
ADP5131
ADP5240
ADP5141
ADP5250
ADP5151
ADP5260
ADP5161
ADP5270
ADP5171
ADP51A11
Pressure Sensor/PS-A (ADP5)
0.118
inch, diameter : 3 mm
0.197
inch, diameter : 3 mm
0.531
inch, diameter : 5.45 mm
0.615
inch, diameter : 5.45 mm
Part No.
M Package
M Package
0.118
inch)
(5 mm
0.197
SMD
DIP
terminal
terminal
ADP5201
ADP5211
ADP5241
ADP5251
ADP5261
ADP5271
ADP51B61
Base type
Nil
:
With glass base (Standard type)
0.118 inch
Low pressure type
1
:
Without glass base
0.118 inch
(Economy type)
0.215 inch
0.215 inch
Note : Some part numbers may not be available
depending on the combination.
Please refer to the Table of PRODUCT TYPES
on the next page.
Low pressure type
L Package
inch)
(13.5 mm
0.531
inch)
(15.6 mm
DIP
DIP
terminal
terminal
ADP51B62
P Package
0.614
inch)
ADP51B63
01
Feb. 2019
Table of Contents
loading

Summary of Contents for Panasonic PS-A

  • Page 1 Pressure Sensor/PS-A (ADP5) Pressure Sensor PS-A Pressure sensor Built-in amplifi er and compensating circuit Features ● Built-in amplifi er and temperature compensation circuit, no need for circuit design and characteristic adjustment ● High accuracy and reliability : overall accuracy ±1.25% FS (Standard), ±2.5% FS (Low-pressure type) ●...
  • Page 2 Pressure Sensor/PS-A (ADP5) Rating ● Standard type Item Standard type (with glass base) Remarks Type of pressure Gauge pressure ✽ 1 Pressure medium Rated pressure (kPa) ±100 −100 1,000 1.5 times Max. applied pressure Twice of the rated pressure the rated...
  • Page 3 Pressure Sensor/PS-A (ADP5) ● Low pressure type Item Economy type (without glass base) Remarks Type of pressure Gauge pressure ✽ 1 Pressure medium Rated pressure (kPa) Max. applied pressure Twice of the rated pressure Ambient temperature 0 °C to +70 °C 32 °F to +158 °F...
  • Page 4 Pressure Sensor/PS-A (ADP5) ● Low pressure type 1 Output voltage 2 THB (high temperature high humidity bias test) ADP51B61 ADP51B61 Drive voltage : 5 V Within 85 °C 185 °F and 85% RH Temperature : 25 °C 77 °F 5 V applied between No.2 (Vdd) and No.3 (GND)
  • Page 5 Pressure Sensor/PS-A (ADP5) 1.00 4.50 6 Temperature/humidity cycle test ADP51B61 4.30 0.80 Exposed to 10 cycles in the temperature and humidity conditions given below. 4.10 Applied pressure : 0kPa 0.60     0.40 3.90 1 cycle (24h) Temp. 65 °C 149 °F...
  • Page 6 Pressure Sensor/PS-A (ADP5) Dimensions The CAD data of the products with a mark can be downloaded from: http://industrial.panasonic.com/ ● Standard type S Package (Terminal direction : DIP terminal Pressure inlet hole length : 3 mm 0.118 inch) ADP51□0 Recommended PC board pattern...
  • Page 7 Pressure Sensor/PS-A (ADP5) Dimensions The CAD data of the products with a mark can be downloaded from: http://industrial.panasonic.com/ ● Standard/Economy type M Package (Terminal direction : DIP terminal Pressure inlet hole length : 5 mm 0.197 inch) ADP51□1/ADP51A11 Recommended PC board pattern...
  • Page 8 Pressure Sensor/PS-A (ADP5) Dimensions The CAD data of the products with a mark can be downloaded from: http://industrial.panasonic.com/ ● Low pressure type M Package (Terminal direction : DIP terminal, Pressure inlet hole length : 5 mm 0.197 inch) ADP51B61 P2.54×3=7.62 P0.100×3=0.300...
  • Page 10 [Scope of Warranty] If a failure or a defect attributable to Panasonic is found during the warranty period, we will promptly provide a replacement or a necessary replacement part or change/repair the defective part free of charge at the location of the purchase or delivery.
  • Page 11 Pressure Sensor/PS-A (ADP5) Notes ■ Mounting Use the land of the printed-circuit board on which the sensor is securely fixed. ■ Soldering Avoid the external thermal influence as the product has a limited thermal capacity due to its compact structure.
  • Page 12 Pressure Sensor/PS-A (ADP5) 4) Malfunction may occur near electric noises from static electricity, lightning, broadcast or amateur radio stations and mobile phones. 5) Avoid use in a place where these products come in contact with water as the sensor does not have a splash- proof construction.

Table of Contents