Table of Contents
loading

Summary of Contents for DeWalt D21585

  • Page 1 D21585...
  • Page 2 Figure 1 Figure 2...
  • Page 3 Figure 3 Figure 4...
  • Page 4 Figure 5 Figure 6...
  • Page 5: Technical Data

    DIAMOND DRILLING MACHINE D21585 Congratulations! Noise values and vibration values (triax vector sum) according to EN61029-1: You have chosen a D WALT tool. Years of experience, thorough product development and (emission sound pressure level) dB(A) 84.3 innovation make D...
  • Page 6: Definitions: Safety Guidelines

    DIAMOND DRILLING MACHINE work area. D21585 5. Store idle tools. WALT declares that these products described When not in use, tools must be stored in a dry...
  • Page 7 english instruction manual. Have defective switches 10. Connect dust extraction equipment. replaced by an authorized service centre. If the tool is provided for the connection of dust Do not use the tool if the switch does not turn extraction and collecting equipment, ensure it on and off.
  • Page 8: Residual Risks

    english Additional Safety Instructions for Residual Risks water supplied Drills In spite of the application of the relevant safety regulations and the implementation of safety • Before use check the drill core bits. Never devices, certain residual risks cannot be avoided. use damaged or deformed core bits.
  • Page 9: Package Contents

    The machine INTENDED USE will be operational after the thermal protection has Your D21585 diamond drilling machine has been cooled down. The time of cooling down depends designed for wet drilling into masonry materials such on the overheating of the motor and the ambient as brick, breeze block, etc., as well as engineered...
  • Page 10: Electrical Safety

    english Water Supply DI-switch (in-line protector PRCD) (fig. 1) The integrated water swivel works directly through the motor shaft to provide continuous cooling of the The machine is equipped with a portable residual core bit in wet drilling applications. current device (PRCD) (R), which protects the user against electric shock by interrupting the circuit Electrical Safety when a leakage current of 10 mA or greater is...
  • Page 11: Prior To Operation

    english Connecting to a Water Supply (fig. 5) WARNIING: Also refer to the drill stand manual. WARNING: 1. Fit the mounting bracket to the base of the • Never use the tool without the PRCD machine. delivered with the tool. 2.
  • Page 12: Troubleshooting

    english • Always observe the safety instructions 2. Adjust the water flow as necessary. and applicable regulations. 3. Proceed as described above. • Be aware of the location of pipework WARNING: If any water comes out and wiring. of the drainage hole at the gear neck, •...
  • Page 13: Protecting The Environment

    english • Disengage drill bit regularly to evacuate WATER PUMP (FIG. 6) cuttings. Removing debris from the working area and cooling Segments and core are burnt the core bit in wet applications, the D215824 water pump (I) ensures water supply where main water •...