Getting Started
This is a brief document designed to quickly get you started setting up your valve manifold with an integrated
Numatics' G2-2 AS-i communication node.
1) Initial Unpacking and Inspection
1) Examine exterior of package for signs of damage. Report any damage to shipping carrier.
2) Remove wrapped manifold assembly from box.
a) Remove manifold assembly from anti-static packaging
b) Retain documentation for installation and configuration
3) Examine manifold assembly for any shipping damage such as:
a) Bent pins or connectors
b) Report any damage to shipping carrier immediately
4) Examine manifold assembly for proper ordered configuration. (Valves, I/O, Protocol, etc.)
2) G2-2 Introduction
Below is an example of a 2012 series valve manifold. This fieldbus manifold series is capable of addressing a
total of up to 16 Inputs and 16 Outputs (using 4 separate AS-i addresses. This would include 16 valve outputs
and 16 input connectors, which are located on the top of the AS-i modules. There are 14 AS-i configurations
currently available. Each of the configurations is available in both standard and extended addressing and
contain different configurations of inputs and outputs. Also located on the top of the AS-i modules are two flat
cable connectors: a 2-pin communication connector (yellow cable) and a 2-pin Aux. power connector (black
cable). These connectors are labeled accordingly.
G2-2 Series AS-i Quick Start Manual
3835051 TDG22ASQS1-4
Subject to change without notice
www.numatics.com/fieldbus
9/06
Page 1
Table of Contents
loading

Summary of Contents for Emerson Numatics G2-2 Series

  • Page 1 G2-2 Series AS-i Quick Start Manual Getting Started This is a brief document designed to quickly get you started setting up your valve manifold with an integrated Numatics’ G2-2 AS-i communication node. 1) Initial Unpacking and Inspection 1) Examine exterior of package for signs of damage. Report any damage to shipping carrier. 2) Remove wrapped manifold assembly from box.
  • Page 2 G2-2 Series AS-i Quick Start Manual 3) AS-i Communication Module Part Numbers Located below are charts for the different AS-i communication modules and boards currently available. Each of the modules has either 1,2,3 or 4 AS-i nodes. This allows the user to choose between different numbers of inputs and coil outputs.
  • Page 3 G2-2 Series AS-i Quick Start Manual AS-i Communication Node I/O Chart Continued: Standard Addressing (239-2059) Standard Addressing (239-2060) Standard Addressing (239-2180) Available Outputs Available Outputs Available Outputs Available Inputs Available Inputs Available Inputs Extended Addressing (239-2165) Extended Addressing (239-2164) Extended Addressing (239-2176) Available Outputs Available Outputs Available Outputs...
  • Page 4 G2-2 Series AS-i Quick Start Manual AS-i Communication Node I/O Chart Continued: Standard Addressing (239-2057) Standard Addressing (239-2177) Standard Addressing (239-2178) Available Outputs Available Outputs Available Outputs Available Inputs Available Inputs Available Inputs Extended Addressing (239-2169) Extended Addressing (239-2168) Extended Addressing (239-2167) Available Outputs Available Outputs Available Outputs...
  • Page 5 G2-2 Series AS-i Quick Start Manual 4) I/O Mapping Example Example: Assumed Settings - Single Z-Boards™ are used with single solenoid valves - Double Z-Boards™ are used with double solenoid valves - Node is configured to use addresses 28, 29, 30 and 31 on an AS-i network (16 Outputs and 12 Inputs total).
  • Page 6 G2-2 Series AS-i Quick Start Manual I/O Mapping Table Example Continued Output Table Node Output Bit Address Valve Coil Valve Coil Valve Coil Valve Coil No. 1 No. 2 No. 3 No. 4 Valve Coil Valve Coil Valve Coil Valve Coil No.
  • Page 7 G2-2 Series AS-i Quick Start Manual 5) Input Pin-Out AS-i Input 8mm (M8) connector Pin-Out Chart Pin No. Function Description +24 VDC Input Power 0 VDC Input Common Input 1 Input Signal (PNP) 3835051 TDG22ASQS1-4 9/06 Subject to change without notice www.numatics.com/fieldbus Page 7...
  • Page 8: Led Functions

    G2-2 Series AS-i Quick Start Manual 6) LED Functions Upon power up, the LEDs indicate the status of the unit. There are up to fourteen LEDs on the G2-2 AS-i module; PWRext, PWRbus, Error, PWRext 2, PWRbus 2, Error 2, and a series of LED’s for inputs (if module includes input capabilities).
  • Page 9: Jumper Settings

    G2-2 Series AS-i Quick Start Manual 7) Jumper Settings There are two jumpers located on the removable AS-i address board (node). These jumpers are for selecting external power (through power connector) or internal power (through communication connector) for the outputs. The Numatics’ AS-i nodes are factory set to operate using external auxiliary power (black cable) for coil outputs.
  • Page 10 G2-2 Series AS-i Quick Start Manual 9) Writing Output Values to the AS-i Node When hexadecimal values are used to operate corresponding I/O, the following reference chart can be used. For example, an input of “E” (hex) would energize outputs 2, 3, and 4 simultaneously. Below is a chart showing hexadecimal and binary write values and the corresponding outputs.
  • Page 11: Factory Default Settings

    G2-2 Series AS-i Quick Start Manual 11) G2-2 AS-i Features Features Description AS-i Spec. Supported Designed to AS-i Specification Revision 2.1 Daisy chained, star, branch lines, or tree structure using flat two wire Bus Topology cabling 12) Factory Default Settings All standard AS-i manifolds ship with specific factory default settings.
  • Page 12: Pour Commencer

    Guide de Démarrage Rapide Série 2-2 - AS-i Pour commencer Ce document décrit le démarrage rapide de votre îlot de distribution à nœud de communication AS-i série G2-2 intégré. 1) Déballage et inspection 1) Inspectez l'emballage extérieur pour détecter tout dommage. Tout dommage constaté doit être signalé au transporteur.
  • Page 13 Guide de Démarrage Rapide Série 2-2 - AS-i 3) Codes des composants du module de communication AS-i Veuillez trouver ci-dessous les schémas des différents modules et cartes électroniques AS-i disponibles à présent. Chaque module est pourvu de 1, 2, 3 ou 4 nœuds AS-i. Ceci permet à l'utilisateur de choisir entre de différents nombres d'entrées et de sorties bobines.
  • Page 14 Guide de Démarrage Rapide Série 2-2 - AS-i Schéma des E/S du module complet de communication AS-i - continuation : Adressage standard (239-2059) Adressage standard (239-2060) Adressage standard (239-2180) Sorties disponibles Sorties disponibles Sorties disponibles Entrées disponibles Entrées disponibles Entrées disponibles Adressage étendu (239-2165) Adressage étendu (239-2164) Adressage étendu (239-2176)
  • Page 15 Guide de Démarrage Rapide Série 2-2 - AS-i Schéma des E/S du module complet de communication AS-i - continuation : Adressage standard (239-2057) Adressage standard (239-2177) Adressage standard (239-2178) Sorties disponibles Sorties disponibles Sorties disponibles Entrées disponibles Entrées disponibles Entrées disponibles Adressage étendu (239-2169) Adressage étendu (239-2168) Adressage étendu (239-2167)
  • Page 16 Guide de Démarrage Rapide Série 2-2 - AS-i 4) Exemple de mapping des E/S Exemple: Assumed Settings - Cartes Z-Boards simples utilisées avec les électrodistributeurs simples - Cartes Z-Boards doubles utilisées avec les électrodistributeurs doubles - Le nœud est configuré pour utiliser les adresses 28, 29, 30 et 31 sur un réseau AS-i (16 sorties et 12 entrées au total).
  • Page 17 Guide de Démarrage Rapide Série 2-2 - AS-i Exemple de mapping des E/S - continuation Tableau des sorties Adresse Bit de sortie du nœud Bobine no. 1 Bobine no. 2 Bobine no. 3 Bobine no. 4 Bobine no. 5 Bobine no. 6 Bobine no.
  • Page 18 Guide de Démarrage Rapide Série 2-2 - AS-i 5) Affectations des broches des entrées Schéma de connexion du connecteur 8 mm (M8) AS-i No. de Fonction Description broche +24VCC Alimentation des entrées 0 VCC Commun d'entrée Entrée 1 Signal d'entrée (PNP) 3835051 TDG22ASQS1-4 9/06...
  • Page 19 Guide de Démarrage Rapide Série 2-2 - AS-i 6) Fonction des voyants LED A la mise sous tension, les voyants LED indiquent l'état de l'unité. Le module AS-I série G2-2 dispose de quatorze voyants LED : PWRext, PWRbus, Error, PWRext 2, PWRbus 2, Error 2, ainsi que d'une série de voyants LED pour les entrées (s'il s'agit d'un module destiné...
  • Page 20 Guide de Démarrage Rapide Série 2-2 - AS-i 7) Réglages des cavaliers La carte d'adressage AS-i détachable (nœud) dispose de deux cavaliers. Ces cavaliers servent à choisir l'alimentation externe (via le connecteur d'alimentation) ou l'alimentation interne (via le connecteur de communication) des sorties.
  • Page 21 Guide de Démarrage Rapide Série 2-2 - AS-i 9) Ecriture des valeurs de sortie sur le nœud AS-i Le tableau de référence suivant peut être utilisé lors de l'utilisation de valeurs hexadécimales pour opérer les E/S correspondantes. Par exemple, une entrée "E" (hex) met simultanément les sorties 2, 3 et 4 sous tension. Ci-dessous vous trouvez un tableau avec les valeurs d'écriture hexadécimales et binaires et les sorties correspondantes.
  • Page 22: Support Technique

    Guide de Démarrage Rapide Série 2-2 - AS-i 11) Caractéristiques du AS-i série G2-2 Caractéristique Description AS-i Spec. Supported Conçu selon la spécification AS-i, Révision 2.1 (Spécifications AS-i supportées) En série (daisy-chain), en étoile, en dérivation ou en structure Topologie de bus arborescente via un câble plat à...