Quick Links

O
PERATING
ROOM AIR CONDITIONER
WINDOW TYPE
COOLING MODEL
AFY16F
REVERSE
CYCLE MODEL
AFY16U
KEEP THIS OPERATION MANUAL
FOR FUTURE REFERENCE
FUJITSU GENERAL LIMITED
M
ANUAL
OPERATING MANUAL
BEDIENUNGSANLEITUNG
MODE D'EMPLOI
MANUAL DE FUNCIONAMIENTO
MANUALE DI ISTRUZIONI
ΕΓΧΕΙΡΙ∆ΙΟ ΛΕΙΤΟΥΡΓΙΑΣ
MANUAL DE INSTRUÇÕES
loading

Summary of Contents for Fujitsu AFY16F

  • Page 1 OPERATING MANUAL BEDIENUNGSANLEITUNG MODE D’EMPLOI MANUAL DE FUNCIONAMIENTO PERATING ANUAL MANUALE DI ISTRUZIONI ΕΓΧΕΙΡΙ∆ΙΟ ΛΕΙΤΟΥΡΓΙΑΣ ROOM AIR CONDITIONER MANUAL DE INSTRUÇÕES WINDOW TYPE COOLING MODEL AFY16F REVERSE CYCLE MODEL AFY16U KEEP THIS OPERATION MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED...
  • Page 2 CONTENTS PRECAUTIONS ............2 CARE AND MAINTENANCE ........13 NAME AND FUNCTION OF PARTS ......6 TROUBLESHOOTING ..........14 AIR CONDITIONER OPERATION ......7 OPERATION DETAILS ..........15 AIR DIRECTION ADJUSTMENT ......10 PRECAUTIONS Before using the appliance, read these “PRECAUTIONS” thoroughly and operate in the correct way. The instructions in this section all relate to safety;...
  • Page 3 PRECAUTIONS DANGER Do not stay in direct cooling airflow for long periods. G Excessive direct exposure to chilled air could be bad for your health. G Be especially careful when going to bed, and in rooms where infants, aged, or sick people are staying.
  • Page 4 PRECAUTIONS CAUTION Provide occasional ventilation during use. Do not direct air flow at fireplaces or G Be careful to provide adequate ventilation particularly heating apparatuses. when using the unit in combination with other heating G Direct air blowing on fires could result in improper apparatus.
  • Page 5 CAUTION Always operate with the air filter installed. Do not touch the heat exchanger radiator G Operating the unit without the air filter could cause fins. excessive dirt to collect on internal parts, leading to G Personal injury could result. malfunction.
  • Page 6 NAME AND FUNCTION OF PARTS For details of operation, see the pages indicated by the mark. Air Conditioner Unit 2 Right-Left Airflow-direction Louvres ( P. 10) Control airflow in the horizontal (right-left) direction. This can also be swept. 3 Up-Down Airflow-direction Louvres (Behind Airflow-direction Louvres) ( P.
  • Page 7 AIR CONDITIONER OPERATION COOLING MODEL Power Supply Connect the Power Supply Plug to an electrical point. G Connect securely, without looseness. G In the case of direct line connections, turn on the breaker. MASTER CONTROL Switch POSITION FUNCTION ) (OFF) The air conditioner is switched off.
  • Page 8 AIR CONDITIONER OPERATION REVERSE CYCLE MODEL Power Supply Connect the Power Supply Plug to an electrical point. G Connect securely, without looseness. G In the case of direct line connections, turn on the breaker. MASTER CONTROL Switch POSITION FUNCTION HIGH POWER Fan (High Speed) and compressor operate - Rapid (RED) heating effect at top capacity.
  • Page 9 COOLING MODEL THERMOSTAT Control Switch Once the THERMOSTAT is set to the desired temperature, the room temperature will be automatically adjusted without excessive or insufficient cooling/heating and thus a comfortable environment is always maintained. The thermostat controls the compressor only, and accordingly the fan is constantly circulating air even during the period when the compressor is off during cooling/ heating operation.
  • Page 10 AIR DIRECTION ADJUSTMENT G Do not put fingers or other objects into the air louvres; an internal fan operates at high speed and could result in personal injury or damage. WARNING! G Do not operate the air conditioner with the airflow louvres blocked, since malfunction could result.
  • Page 11 Air Direction Adjustment by SUPER WAVE Move the SELECT LEVER fully to “NEUTRAL”. Set the Right-Left Airflow-direction Louvres and SELECT LEVER according to the airflow direction you required as described below. Set the SELECT LEVER within “SUPER WAVE ZONE” range. Set the SUPER WAVE Switch to “ON”. NOTE: If the MASTER CONTROL Switch is set to “)”, set it to the other position.
  • Page 12 AIR DIRECTION ADJUSTMENT Adjustment Super Wave With this air conditioner, 3 Airflow-directions are available and for each direction, the required sweep angle can be set. Left Side Centre Right Side Blowing Direction Minimum Minimum Minimum Adjusting the Right- Left Airflow-direc- tion Louvres Lightly move the Right-Left Position the Right-Left...
  • Page 13 CARE AND MAINTENANCE Before cleaning the unit, be sure to stop the unit and disconnect the power supply. CAUTION! 1. Disconnect the power plug. 2. Turn off the electrical breaker. G A fan operates at high speed inside the unit, and personal injury could result. Cleaning the Air Filter Cleaning the Indoor Unit If dirt is allowed to collect in the air filter, the airflow will...
  • Page 14 TROUBLESHOOTING In the event of a malfunction (burning smell, etc.), immediately stop operation, disconnect the power plug, and consult authorized service personnel. WARNING! Merely turning off the unit's power switch will not completely disconnect the unit from the power source. Always be sure to disconnect the power plug or turn off your circuit breaker to ensure that power is completely off.
  • Page 15 OPERATION DETAILS Please read and understand the following details regarding this air conditioner. Operation and Performance Temperature and Humidity Range Permissible ranges of temperature and humidity are as Heating Performance follows: G This air conditioner uses a heat pump which absorbs Cooling Outdoor temperature: heat from outside air and brings it indoors.
  • Page 16 ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○...