CP410
Installation and Operation Manual
English
ABB, 1SBC159101M0202 2008-09
Table of Contents
loading

Summary of Contents for ABB CP410M

  • Page 1 CP410 Installation and Operation Manual English ABB, 1SBC159101M0202 2008-09...
  • Page 2 Document number: ABB, 1SBC159101M0202 Please read the entire installation manual prior to installing and using this equipment. Only qualified personnel may install, operate or repair this equipment. ABB is not responsible for modi- fied, altered or renovated equipment. Because the equipment has a wide range of applications, users must acquire the appropriate knowledge to use the equipment properly in their specific applications.
  • Page 3: Table Of Contents

    7 Operation ..................... 15 Self Test ..................15 System Menu ................16 Key Pad..................17 Bench and Function Tests ............18 Setting Parameters..............18 Downloading an Application ............. 19 Uploading an Application ............20 Copying an Application ............. 21 Passwords................... 22 ABB, 1SBC159101M0202...
  • Page 4 Contents ABB, 1SBC159101M0202...
  • Page 5: Safety Precautions

    – The supplier neither guarantees that the operator terminal is suitable for your particular application, nor assumes responsibility for your product design, in- stallation or operation. ABB, 1SBC159101M0202...
  • Page 6 Dismantling and Scrapping – The operator terminal or parts thereof shall be recycled according to local regulations. – The following components contain substances that might be hazardous to health and the environment: lithium battery, electrolytic capacitor and display. ABB, 1SBC159101M0202...
  • Page 7: Installation

    Installation Installation Package Contents The following parts are found in the box: – Operator terminal CP410 CP410 – 4 installation fasteners – Power connector (connected to the 24 V DC power input) – Installation and operation manual (1SBC159101M0202) ABB, 1SBC159101M0202...
  • Page 8: Product Specifications

    20 - 90% RH non-condensed Vibration endurance 0.5 mm displacement, 10-55 Hz, 2 hours per X-, Y- and Z- axis directions Shock endurance 10 G, 11 ms 3 times in each direction of X-, Y- and Z-axes EN-61000-6-4, EN-61000-6-2 Cooling Natural cooling ABB, 1SBC159101M0202...
  • Page 9: Description Of Parts

    Product Specifications Description of Parts Front Fixture mounting holes Power lamp Communication lamp Function and numerical keys Display Back DIP switches (1-10) Contrast adjustment COM2: RS232/RS422/RS485 DC power input ABB, 1SBC159101M0202...
  • Page 10: External And Cut-Out Dimensions

    Product Specifications External and Cut-out Dimensions CUTOUT DIMENSION UNIT: mm CP410 Mounting Procedure 1. Cut out the control front panel to match the dimensions (mm) below. ABB, 1SBC159101M0202...
  • Page 11 STEP 1 STEP 2 STEP 3 Maximum torque: Maximum torgue: 0.3 Nm 0.4~0.5 Nm (3.54~4.42 lb-in) ° 3. The operator terminal is to be installed within the angle of 0 to 135 shown below. ABB, 1SBC159101M0202...
  • Page 12: Grounding

    The power connector is already plugged into the power input of operator terminal when the package is first opened. ° Use copper conductors only, 60/75 Wire Gauge Stripped Type Torque (AWG) Length Solid 28-12 7-8 mm 4.5 lb-in Stranded 30-12 7-8 mm 4.5 lb-in DC 24V ABB, 1SBC159101M0202...
  • Page 13: Dip Switches

    Reserved (no function) SW10 Com2 Port For RS485, this switch has to be set ON. For RS422, this switch has to be set OFF. For RS232, this switch has no effect. ABB, 1SBC159101M0202...
  • Page 14: Communication Port

    LCD Contrast Adjustment The potentiometer on the back of the operator terminal is used to adjust LCD Contrast (STN LCD). Use a small screwdriver to turn the potentiometer (clock- wise = contrast down; counter-clockwise = contrast up). ABB, 1SBC159101M0202...
  • Page 15: Operation

    After downloading again, all items should pass the self-test. Note: When using the operator terminal for the first time, remember to reset the real time clock (RTC). ABB, 1SBC159101M0202...
  • Page 16: System Menu

    Sets up the internal time clock and communication parameters in the operator terminal. to move to desired field and to set the value of the field. F8 - Copy Copies application data to another CP410. F9 - Run Runs the application. ABB, 1SBC159101M0202...
  • Page 17: Key Pad

    Please see the CP400Soft User’s Manual for details. When a key is pressed, the operator terminal will make a “beep” sound to signal that a command is pressed. The default setting, a 200 ms beep, can be config- ured in CP400Soft. ABB, 1SBC159101M0202...
  • Page 18: Bench And Function Tests

    Remember to set dip switch SW5 = ON if parameters are set in the operator ter- minal. To set parameters in CP400Soft, select Application/Workstation Setup. Select the Connection tab to set communication parameters. Note: Remember to set dip switch SW5 = OFF if parameters are set in CP400Soft. ABB, 1SBC159101M0202...
  • Page 19: Downloading An Application

    Then select Application/Download Firmware/Application in CP400Soft if it is the first time to download the application to the operator terminal; otherwise, select Application/Download Application. The following appears on the screen while the operator terminal is downloading: ABB, 1SBC159101M0202...
  • Page 20: Uploading An Application

    *.V6F file. Thus a source file can serve the purposes of maintenance and modification. Note: When uploading for the first time, make sure to first run the application once, or else the upload function will not work. ABB, 1SBC159101M0202...
  • Page 21: Copying An Application

    For information about setting a password, please see section Passwords. The following appears on the screens during the copying: Note: When copying for the first time, make sure to first run the application once, or else the copy function will not work. ABB, 1SBC159101M0202...
  • Page 22: Passwords

    After registering passwords and user levels, set the dip switch SW6 = ON (i.e. password required). Restart the operator terminal and after the self-test the user will be prompted to enter a password in order to run the operator terminal. ABB, 1SBC159101M0202...
  • Page 23 The user will need a password with at least the level of privilege that has been set for the button. This function can restrict users to ac- cess to certain parts of the application. ABB, 1SBC159101M0202...
  • Page 24 CP410 to another. Note that setting this password is different from the passwords set in Scenario 1-3. To set this password, select Application/Workstation Setup in CP400Soft. Under the Password tab, the designer is able to set the password. ABB, 1SBC159101M0202...
  • Page 25 ABB FRANCE ABB STOTZ-KONTAKT GmbH Division Automation Products Po Box 10 16 80 Export Department 69006 Heidelberg 10 rue Ampère Germany 69685 Chassieu Tel. : +49 (0) 6221/701-1190 France Fax. : +49 (0) 6221/701-1333 Tel. : +33 (0) 4 72 22 17 22 Fax.