Quick Links

Installation
Cable Installation
4.6
Cable Installation
In this section:
4.6.1
Connect Frame Ground Cable
4.6.2
Connect eCPRI Optical Cable
4.6.3
Connect AISG Cables
4.6.4
Connect RF Cables
4.6.5
Connect DC –48 V Power Cable
The following sections describe how to connect all necessary cables to the RU.
Important: Do not use a cable that contains red phosphorus as a flame retardant. This may cause
problems, for example, heat generation and emitting smoke.
Important: Ensure the cable connector gland or clamp is the correct size for the selected cable
diameter to prevent water ingress.
4.6.1
Connect Frame Ground Cable
This procedure describes how to connect a Frame Ground (FG) cable to the RU.
Prerequisites:
■ RU mounted and not powered up
■ Available AWG ground cable with two hole lug (green or green with yellow stripe, 0.625 mm hole spacing)
■ Weatherproofing method to prevent moisture intrusion
■ 13 mm socket
■ Philips screwdriver
Danger: Use properly insulated tools and perform all safety
precautions in accordance with local safety practices when working
on or around power terminals, power cables, and power connectors.
Contacting power terminals, uninsulated conductors, cable wiring,
or any connector that could be part of a live electrical circuit can
result in death or serious personal injury.
·
Issue 1.1, May 2021
Release 1.0
Danger: Utilisez des outils correctement isolés et appliquez toutes
les précautions de sécurité conformément à la sécurité locale
pratiques lorsque vous travaillez sur ou autour des bornes
d'alimentation, des câbles d'alimentation et des connecteurs
d'alimentation. Contacter bornes d'alimentation, conducteurs non
isolés, câblage de câbles ou tout connecteur pouvant faire partie
d'un un circuit électrique peut entraîner la mort ou des blessures
graves.
112
Fujitsu and Fujitsu Customer Use Only
loading

Summary of Contents for Fujitsu CFD5GRUDB3

  • Page 1 électrique peut entraîner la mort ou des blessures graves. Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021 Release 1.0...
  • Page 2: Installation

    Connect the other end of the FG cable to a building exterior ground location. Step 5 Apply weatherproofing to the FG cable connector per local guidelines to protect from moisture intrusion. Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021...
  • Page 3 Installation Cable Installation Note: Fujitsu recommends using industry standard UL approved self-fusing tape, but users may use any UL approved weatherproofing material. Refer to Weatherproofing RU Connections for more information about weatherproofing methods. ✓  This task is complete. 4.6.2 Connect eCPRI Optical Cable This procedure describes how to connect optical cable to the RU.
  • Page 4 Installation Cable Installation Figure 29 eCPRI Port Location Figure 30 Remove Protective Cap Step 2 Install the SFP into the eCPRI port. Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021 Release 1.0...
  • Page 5 Step 3 Push the SFP into the port until the lever closes fully. Figure 32 SFP Module Inserted Step 4 Remove the protective covers from both mating connectors. Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021 Release 1.0...
  • Page 6 Remove Cap from Optical Cable Step 6 Pull back on the fiber enclosure until the cylindrical cable container is completely visible. Step 7 Clean the optical fiber connections. Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021 Release 1.0...
  • Page 7 Ensure the locking latches of the LC fiber connectors are snapped into position. Step 10 Align the connector key on connector to the connector on the RU and insert the connector. Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021...
  • Page 8 Installation Cable Installation Figure 36 Align Connector Step 11 Insert the cable and turn the enclosure sub-assembly clockwise until it clicks into place. Figure 37 Insert Connector Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021 Release 1.0...
  • Page 9 Step 13 Apply weatherproofing to the SFP cable connector per local guidelines to protect from moisture intrusion. Note: Fujitsu recommends using industry standard UL approved self-fusing tape, but users may use any UL approved weatherproofing material. Refer to Weatherproofing RU Connections for more information about weatherproofing methods.
  • Page 10 Step 6 Apply weatherproofing to the AISG cable connector per local guidelines to prevent moisture intrusion. Note: Fujitsu recommends using industry standard UL approved self-fusing tape, but users may use any UL approved weatherproofing material. Refer to Weatherproofing RU Connections for more information about weatherproofing methods.
  • Page 11 If necessary, insert two weatherproofing sleeves onto each cable. Step 3 Connect each RF cable to its corresponding port on the RU. Step 4 Secure the RF cables along their route. Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021 Release 1.0...
  • Page 12 Step 6 Apply weatherproofing to the RF cable connectors per local guidelines to protect from moisture intrusion. Note: Fujitsu recommends using industry standard UL approved self-fusing tape, but users may use any UL approved weatherproofing material. Refer to Weatherproofing RU Connections for more information about weatherproofing methods.
  • Page 13 Figure 41 Remove Dust Cover Step 2 Align the key in the plug with the inner and outer connector grooves. Figure 42 Align Key Plug with Port Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021 Release 1.0...
  • Page 14 Note: The RU has reverse-polarity protection in case the DC power leads are connected incorrectly. Step 4 Turn the locking ring clockwise until tightened. Figure 43 Tighten Power Cable ✓  This task is complete. Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021 Release 1.0...
  • Page 15 Powering up an RU has the following environmental requirements: ■ Keep the temperature and humidity within the specified conditions. ■ Do not place around objects that obstruct the flow of air. Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021...
  • Page 16 Power Up ■ Do not input optical signals higher than the maximum light level as this may damage the optical receiver. ■ Do not submerge or bury in snow. Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021...
  • Page 17 Note: It takes less than one minute for the RU to fully power up. Step 3 Verify weatherproofing is applied to each cable connector according to local guidelines. Note: Fujitsu recommends using industry standard UL approved self-fusing tape, but users may use any UL approved weatherproofing material. Refer to Weatherproofing RU Connections for more information about weatherproofing methods.
  • Page 18 Set the circuit breaker to ON at the DC power supply. Note: Reset starts when RU detects power on. Step 2 Wait approximately one minute for the RU to fully power up. Continue with the next task. Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021 Release 1.0...
  • Page 19: Check Led Status

    Note: If the LED is not blinking green after reset, then RU status is not in a normal state. Step 2 Close the maintenance window cover. Continue with the next task. Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021 Release 1.0...
  • Page 20: Led Display

    Red off Transmit ON Green on Red off Blocking Green blinking Red blinking Major Alarm Green off Red blinking Minor Alarm Green blinking or Green on Red blinking Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021 Release 1.0...
  • Page 21 Table 37 (Cont.) RU LED Status RU Status Operation Fault Fronthaul L1 disconnection L1 link found (M-Plane not Green blinking found) L1 & M-Plane link found Green on Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021 Release 1.0...
  • Page 22 Step 2 Confirm with the customer that the work is completed successfully. Step 3 Clean up area before leaving the customer premises. ✓  This task is complete. Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021 Release 1.0...
  • Page 23 RU Confirmation The RU must be receiving configuration information from the DU during the confirmation. The method and procedure of the confirmation are presented by the DU vendor. Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021 Release 1.0...
  • Page 24 Maintenance and Trouble Clearing Maintenance and Trouble Clearing In this chapter: RU Alarms Replace RU Mounted on Pole Replace RU Mounted on Wall Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021 Release 1.0...
  • Page 25 Corrective Action SFP not implemented Critical Reestablish L1 link or M-Plane SFP LOS SFP TxFault SFP 12C Access NG L1 OFF M-Plane OFF Note: Stops all RF transmission Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021 Release 1.0...
  • Page 26 Cold start Probable Cause Severity Corrective Action RU too cold Major Raise the temperature to at least -20 °C Note: Stops all RF transmission Note: PA device on Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021 Release 1.0...
  • Page 27 Note: Stops RF transmission at port with alarm Table 51 RX out of order Probable Cause Severity Corrective Action RxGainALM Major Reset Note: Stops RF transmission at port with alarm Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021 Release 1.0...
  • Page 28 Note: Reports alarm only Table 56 RU Local Access Attempt Probable Cause Severity Corrective Action A local access attempt has been made on Minor Take no action the RU Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021 Release 1.0...
  • Page 29 Caution: The RU is heavy. Fujitsu recommends removing the RU on Attention: Le RU est lourd. Fujitsu recommande de retirer l'EF d'une a two-person team to avoid damage to the unit or injury to the user.
  • Page 30 Remove the M10 x 30 mm bolts from the top of the mounting plate. Step 4 Cautiously lift the RU from the mounting plate and lower to the ground using the eye bolts per local guidelines. Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021...
  • Page 31 Step 5 Mount the replacement RU to the pole by aligning the hooks on the plate adapter with the two holes at the top of the wall mounting plate. Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021...
  • Page 32 Do not tighten the bolts yet. Step 7 Torque each bolt on the top and bottom of the mounting plate using a 11/16 socket to 27 Nm. ✓  This task is complete. Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021 Release 1.0...
  • Page 33 Caution: The RU is heavy. Fujitsu recommends installing the RU Attention: Le RU est lourd. Fujitsu recommande de retirer l'EF d'une with a two-person team to avoid damage to the unit or injury to the équipe de deux personnes pour éviter d'endommager l'appareil ou...
  • Page 34 Remove M10 Bolts Step 4 Unhook the RU from the Wall Mount Plate and place it somewhere safe. Note: Use the eye bolts to hoist the RU. Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021 Release 1.0...
  • Page 35 Mount the replacement RU by aligning the holes on the Wall Mount Plate Adapter with the holes on the top of the Wall Mount Plate and hook it in place. Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021...
  • Page 36 Ensure the shoulder of the stepped bushing is perfectly fit inside of the hole on the L-bracket for proper alignment. Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021...
  • Page 37 Insulating Bushing Split Washer Figure 51 Securing RU to Wall Mount Plate Step 7 Torque all four M10 bolts to 27 Nm to secure the RU in place. Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021 Release 1.0...
  • Page 38 Maintenance and Trouble Clearing Replace RU Mounted on Wall Figure 52 Wall Mount Final Result ✓  This task is complete. Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021 Release 1.0...
  • Page 39 The following sections describe how to detach a RU from a wall or pole mount and how to remove the power cables. Caution: Use care when handling the RU, as it is heavy. Fujitsu Attention: Manipulez le RU avec précaution car il est lourd. Fujitsu recommends removing the RU on a two-person team to avoid recommande d'installer le RU surdeuxéquipe de personnes pour...
  • Page 40: Cable Removal

    Locate –48V DC power cable connection on the bottom of the RU. Step 3 Loosen the connector ring by rotating the connector ring counter-clockwise. Step 4 Remove the connector from the –48V DC port on the RU. Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021 Release 1.0...
  • Page 41 Insert protective covers into the RF ports. Continue with the next task. 7.1.3 Remove AISG Cable This procedure describes how to remove AISG RET cable from the RU. Prerequisite: ■ RU powered off Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021 Release 1.0...
  • Page 42 électrique peut entraîner la mort ou des blessures graves. Step 1 Separate the two protective covers. Step 2 Turn the optic sub-assembly enclosure counter-clockwise and gently pull the connector from the SFP port. Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021 Release 1.0...
  • Page 43 Step 2 Lift the lever on the SFP. Step 3 Pull the SFP out of the eCPRI port. Step 4 Apply a protective cover to the eCPRI port. Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021 Release 1.0...
  • Page 44 électrique peut entraîner la mort ou des blessures graves. Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021 Release 1.0...
  • Page 45 Unscrew the RU end of the FG cable and remove. Step 3 Using a screwdriver or 13 mm socket, detach screws from the ground point. ✓  This task is complete. Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021 Release 1.0...
  • Page 46 Caution: The RU is heavy. Fujitsu recommends removing the RU on Attention: Le RU est lourd. Fujitsu recommande de retirer l'EF d'une a two-person team to avoid damage to the unit or injury to the user.
  • Page 47 Remove the M10 x 30 mm bolts from the top of the mounting plate. Step 4 Cautiously lift the RU from the mounting plate and lower to the ground using the eye bolts per local guidelines. Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021...
  • Page 48 Remove the jam nuts from each of the four 10-inch 3/8 bolts holding the small and large crossmembers together. Step 6 Disconnect the small crossmembers from the large crossmembers by removing the 10-inch 3/8 bolts. Note: Fujitsu recommends removing the pole mount plate on a 2-person team to prevent injury or damage to the equipment. ✓ ...
  • Page 49 RU before starting this procedure. déconnectés de l'EF avant de commencer cette procédure. Caution: The RU is heavy. Fujitsu recommends removing the RU on Attention: Le RU est lourd. Fujitsu recommande de retirer l'EF d'une a two-person team to avoid damage to the unit or injury to the user.
  • Page 50 Remove M10 Bolts Step 3 Unhook the RU from the Wall Mount Plate and place it somewhere safe. Note: Use the eye bolts to hoist the RU. Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021 Release 1.0...
  • Page 51 Removing Radio from Wall Mount Step 4 Remove the RU Wall Mount Plate from the wall by unscrewing all four nuts on the M10 bolts in the wall. Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021 Release 1.0...
  • Page 52 Figure 58 Removing Wall Mount Plate from Wall Step 5 Remove the Wall Mount Plate and the M10 bolts from the wall. ✓  This task is complete. Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021 Release 1.0...
  • Page 53 Unscrew the two M10 x 30 bolts from the front of the mounting adapter plate. Figure 59 Removing Bolts from Mounting Adapter Plate Step 2 Remove the flat and split washers, insulating bushings, and mounting plate from the RU. Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021 Release 1.0...
  • Page 54 Removal Detach RU Mounting Adapter Plate Figure 60 Removing Mounting Adapter Plate Continue with the next task. Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021 Release 1.0...
  • Page 55 Step 2 Unscrew the eight M8 screws on the L-brackets on each side of the RU. Step 3 Remove the L-brackets from each side of the RU. Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021 Release 1.0...
  • Page 56 Flat Washer Flat Washer Split Washer M8 Hex Bolt NOTE: Use torque value of 9.28 N/m Figure 61 Removing L-Brackets and Eye Bolts ✓  This task is complete. Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021 Release 1.0...
  • Page 57 ■ 3GPP 38.113 NR Base Station (BS) Electromagnetic Compatibility (EMC) v15.9.0 (2020-03) ■ ETSI EN 300 019-2-4, Severity class 1 (Vibration) ■ ETSI EN300 019-1-1 Class 1.3 (Storage) ■ IEC-61000-4-5 (Surge Protection) Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021 Release 1.0...
  • Page 58 • Private Land Mobile Radio Services: CFR 47, Part 90 • FCC rules on output power as outlined in part 90 (90.617, 90.691) and part 27 (27.53). ■ 3GPP TS.25.461 NR Iuant interface: Layer1 v6.5.0 (2005-12) Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021...
  • Page 59 Zero Touch Provisioning (ZTP) allows remote configuration of a device, with little to no pre-defined information in the Radio Unit (RU). The following figures outline the ZTP sequence. Figure 62 Acquiring IP Address Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021 Release 1.0...
  • Page 60 ZTP Overview Figure 63 Configuration Files are Requested and Sent Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021 Release 1.0...
  • Page 61 ZTP Overview Figure 64 Configuration Files Loaded and RU Becomes Operational Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021 Release 1.0...
  • Page 62 Reel-type cleaners can be used for LC connector ferrule end surface cleaning. Important: Follow local safety precautions and guidelines regarding fiber optical connector cleaning. Figure 65 Reel-type Cleaner Tool (Closed) Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021 Release 1.0...
  • Page 63 Optical Connector Cleaning Figure 66 Reel-type Cleaner Tool (Opened) Figure 67 Stick Cleaner Tool Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021 Release 1.0...
  • Page 64 After cleaning, promptly install in the connector or replace protection cap and store it. Note: Install or store the connector within 15 minutes of cleaning to prevent unnecessary dirt from entering the connector. Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021...
  • Page 65: Additional Instructions

    ■ Do not wipe the boots of the connector for open circuit prevention. ■ Do not touch the ferrule part of the connector to the polyethylene cleaner guide. ■ Do not use a cleaner except to clean the ferrule. Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021...
  • Page 66 ■ Clean again if the connector end surface is touched after the cleaning. ■ Do not use the same stick-type cleaner more than once. ■ Do not use a cleaner except to clean the ferrule. Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021...
  • Page 67 ■ Self-fusing tape ■ Cold shrink tubing ■ Heat shrink tubing ■ Rubber boots ■ Clamshell covers Fujitsu recommends using industry standard UL approved self-fusing tape, but users may use any UL approved weatherproofing material. 1st Layer 2nd Layer 3rd Layer...
  • Page 68 Digital Pre-Distortion Distributed Unit Enhanced Common Public Radio Interface eCPRI Electromagnetic Compatibility Element Management System Error Vector Magnitude Frequency Division Duplex Frame Ground Fujitsu Technical Assistance Center FTAC Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021 Release 1.0...
  • Page 69 Received Total Wideband Power RTWP Radio Unit Sub Carrier Spacing Safety Extra Low Voltage SELV Small Form-Factor Pluggable Software Transceiver Telecom Time Slave Clock T-TSC Unit Investigation Request Underwriters Laboratories Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021 Release 1.0...
  • Page 70 Glossary Voltage Standing Wave Ratio VSWR Width Waste Electrical and Electronic Equipment WEEE Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021 Release 1.0...
  • Page 71 Complete RU Installation frequency error conducted emission front-haul port Confirmation Before Commissioning 128, Connect RU Cables 112, 114, Connection With DU controls Counter General Blocking Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021 Release 1.0...
  • Page 72 63, reference sensitivity (NF) Narrowband Blocking repairing defective equipment Narrowband Intermodulation Resistibility of Lightning noise RET (AISG) port RET Interface Connector Pin Assign RET port Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021 Release 1.0...
  • Page 73 Transmission Blanking transmitter intermodulation transmitter specifications Transport and Storage Requirements transport requirements TX control function Fujitsu and Fujitsu Customer Use Only · Issue 1.1, May 2021 Release 1.0...