LG ABNW18GM1AO Manual

LG ABNW18GM1AO Manual

Multi/single indoor unit

Quick Links

Indoor unit
Ceiling concealed duct - Middle static pressure
MULTI/SINGLE
1.List of Functions
2.Specifications
3.Dimensions
4.Piping diagrams
5.Wiring diagrams
6.External static pressure & Air flow
7.Sound levels
8.Installation
Table of Contents
loading

Summary of Contents for LG ABNW18GM1AO

  • Page 1 Indoor unit Ceiling concealed duct - Middle static pressure MULTI/SINGLE 1.List of Functions 2.Specifications 3.Dimensions 4.Piping diagrams 5.Wiring diagrams 6.External static pressure & Air flow 7.Sound levels 8.Installation...
  • Page 2 MULTI/SINGLE Indoor unit Ceiling concealed duct - Middle static pressure 1. List of functions  List of function ABNW18GM1A0 [CM18 N14], ABNW24GM1A0 [CM24 N14] ABNW30GM1A0 [UM30 N14], ABNW36GM2A0 [UM36 N24] Category Functions ABNW42GM2A0 [UM42 N24], ABNW48GM3A0 [UM48 N34] ABNW60GM3A0 [UM60 N34] Air supply outlet Airflow direction control (left &...
  • Page 3 MULTI/SINGLE Indoor unit Ceiling concealed duct - Middle static pressure 1. List of functions  Accessory Compatibility List ABNW18GM1A0 [CM18 N14], ABNW24GM1A0 [CM24 N14] ABNW30GM1A0 [UM30 N14], Category Product Remark ABNW36GM2A0 [UM36 N24] ABNW42GM2A0 [UM42 N24], ABNW48GM3A0 [UM48 N34] ABNW60GM3A0 [UM60 N34] Wireless Remote Controller PQWRHQ0FDB Heat Pump...
  • Page 4 MULTI/SINGLE Indoor unit Ceiling concealed duct - Middle static pressure 2. Specifications ABNW18GM1A0 ABNW24GM1A0 Model Name [CM18 N14] [CM24 N14] 220-240, 1, 50 220-240, 1, 50 Power Supply V, Ø, Hz 220, 1, 60 220, 1, 60 Power Input Running Current 0.40 0.50 W x H x D...
  • Page 5 MULTI/SINGLE Indoor unit Ceiling concealed duct - Middle static pressure 2. Specifications ABNW30GM1A0 ABNW36GM2A0 Model Name [UM30 N14] [UM36 N24] 220-240, 1, 50 220-240, 1, 50 Power Supply V, Ø, Hz 220, 1, 60 220, 1, 60 Power Input Running Current 0.80 1.30 W x H x D...
  • Page 6 MULTI/SINGLE Indoor unit Ceiling concealed duct - Middle static pressure 2. Specifications ABNW42GM2A0 ABNW48GM3A0 Model Name [UM42 N24] [UM48 N34] 220-240, 1, 50 220-240, 1, 50 Power Supply V, Ø, Hz 220, 1, 60 220, 1, 60 Power Input Running Current 1.50 1.10 W x H x D...
  • Page 7 MULTI/SINGLE Indoor unit Ceiling concealed duct - Middle static pressure 2. Specifications ABNW60GM3A0 Model Name [UM60 N34] 220-240, 1, 50 Power Supply V, Ø, Hz 220, 1, 60 Power Input Running Current 1.65 W x H x D 1,250 × 360 × 700 Dimensions Body W x H x D...
  • Page 8 MULTI/SINGLE Indoor unit Ceiling concealed duct - Middle static pressure 3. Dimensions ABNW18GM1A0 [CM18 N14] / ABNW24GM1A0 [CM24 N14] / ABNW30GM1A0 [UM30 N14]...
  • Page 9 MULTI/SINGLE Indoor unit Ceiling concealed duct - Middle static pressure 3. Dimensions ABNW36GM2A0 [UM36 N24] / ABNW42GM2A0 [UM42 N24]...
  • Page 10 MULTI/SINGLE Indoor unit Ceiling concealed duct - Middle static pressure 3. Dimensions ABNW48GM3A0 [UM48 N34] / ABNW60GM3A0 [UM60 N34]...
  • Page 11 MULTI/SINGLE Indoor unit Ceiling concealed duct - Middle static pressure 4. Piping diagrams Model : ABNW-GM1A0 [CM- N14] Gas pipe connection port Heat exchanger (flare connection) Heating Thermistor for Cooling Sirocco Fan evaporator outlet Thermistor for temperature suction air temperature Thermistor for evaporator inlet temperature...
  • Page 12 MULTI/SINGLE Indoor unit Ceiling concealed duct - Middle static pressure 4. Piping diagrams Models : ABNW-GM2A0 [CM- N24], ABNW-GM3A0 [CM- N34] Gas pipe connection port Heat exchanger (flare connection) Heating Thermistor for Cooling Sirocco Fan evaporator outlet Thermistor for temperature suction air temperature Thermistor for...
  • Page 13 MULTI/SINGLE Indoor unit Ceiling concealed duct - Middle static pressure 5. Wiring Diagrams Model : ABNW18GM1A0 [CM18 N14]...
  • Page 14 MULTI/SINGLE Indoor unit Ceiling concealed duct - Middle static pressure 5. Wiring Diagrams Model : ABNW24GM1A0 [CM24 N14], ABNW30GM1A0 [CM30 N14]...
  • Page 15 MULTI/SINGLE Indoor unit Ceiling concealed duct - Middle static pressure 5. Wiring Diagrams Model : ABNW36GM2A0 [CM36 N24], ABNW42GM2A0 [CM42 N24]...
  • Page 16 MULTI/SINGLE Indoor unit Ceiling concealed duct - Middle static pressure 5. Wiring Diagrams Model : ABNW48GM3A0 [CM48 N34], ABNW60GM3A0 [CM60 N34]...
  • Page 17 MULTI/SINGLE Indoor unit Ceiling concealed duct - Middle static pressure 6. External Static Pressure & Air Flow How to Set E.S.P. on the remote controller? This is the function that decides the strength of the wind for each wind level and because this function is to make the installation easier.
  • Page 18 MULTI/SINGLE Indoor unit Ceiling concealed duct - Middle static pressure 6. External Static Pressure & Air Flow Installer Setting - Static Pressure Step Setting This function is applied to only duct type. Setting this in other cases will cause malfunction. This function is only available on some products.
  • Page 19: Table Of Contents

    MULTI/SINGLE Indoor unit Ceiling concealed duct - Middle static pressure 6. External Static Pressure & Air Flow Table 1 Static Pressure[mmAq(Pa)] 2(20) 2.5(25) 3(29) 4(39) 6(59) 8(78) 10(98) 12(118) 13(127) 14(137) 15(147) Model Step Setting Value 32:01 32:02 32:03 32:04 32:05 32:06 32:07...
  • Page 20 MULTI/SINGLE Indoor unit Ceiling concealed duct - Middle static pressure 6. External Static Pressure & Air Flow Note 1. Be sure to set the value refering table 1. Unexpected set value will cause mal-function. 2. Table 1 is based at 230V. According to the fluctuation of voltage, air flow rate varies. 3.
  • Page 21: Table 2

    MULTI/SINGLE Indoor unit Ceiling concealed duct - Middle static pressure 6. External Static Pressure & Air Flow Table 2  ABNW18GM1A0 [CM18 N14], ABNW24GM1A0 [CM24 N14] (Unit : CMM) Static Pressure (mmAq(Pa)) Setting value 2.5(25) 4(39) 6(59) 8(78) 10(98) 12(118) 14(137) 15(147) 11.3...
  • Page 22 MULTI/SINGLE Indoor unit Ceiling concealed duct - Middle static pressure 6. External Static Pressure & Air Flow  ABNW42GM2A0 [CM42 N24] (Unit : CMM) Static Pressure (mmAq(Pa)) Setting value 5(49) 6(59) 8(78) 10(98) 12(118) 14(137) 15(147) 22.2 25.1 22.3 1000 28.0 25.4 1050...
  • Page 23: Low

    MULTI/SINGLE Indoor unit Ceiling concealed duct - Middle static pressure 7. Sound levels 7.1 Sound pressure level Overall Note 1.Sound measured at 1.5m away from the center of the unit. DISCHARGE SUCTION 2.Operating condition • Power source : 220-240V 50 Hz / 220V 60 Hz DUCT DUCT •...
  • Page 24: Low

    MULTI/SINGLE Indoor unit Ceiling concealed duct - Middle static pressure 7. Sound levels  External Static Pressure 4(39) [mmAq(Pa)] ABNW30GM1A0 [UM30 N14] ABNW36GM2A0 [UM36 N24] High High ▲ Mid ▲ Mid NC-65 NC-65 NC-60 NC-60 NC-55 NC-55 NC-50 NC-50 NC-45 NC-45 NC-40 NC-40...
  • Page 25 MULTI/SINGLE Indoor unit Ceiling concealed duct - Middle static pressure 7. Sound levels ABNW60GM3A0 [UM60 N34] High ▲ Mid NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 Approximate NC-20 Hearing Threshold NC-15 1 000 2 000 4 000 8 000 Octave Band Center Frequency (Hz) ...
  • Page 26 MULTI/SINGLE Indoor unit Ceiling concealed duct - Middle static pressure 7. Sound levels ABNW60GM3A0 [UM60 N34] High ▲ Mid NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 Approximate NC-20 Hearing Threshold NC-15 1 000 2 000 4 000 8 000 Octave Band Center Frequency (Hz) ...
  • Page 27 MULTI/SINGLE Indoor unit Ceiling concealed duct - Middle static pressure 7. Sound levels ABNW60GM3A0 [UM60 N34] High ▲ Mid NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 Approximate NC-20 Hearing Threshold NC-15 1 000 2 000 4 000 8 000 Octave Band Center Frequency (Hz) ...
  • Page 28 MULTI/SINGLE Indoor unit Ceiling concealed duct - Middle static pressure 7. Sound levels ABNW60GM3A0 [UM60 N34] High ▲ Mid NC-65 NC-60 NC-55 NC-50 NC-45 NC-40 NC-35 NC-30 NC-25 Approximate NC-20 Hearing Threshold NC-15 1 000 2 000 4 000 8 000 Octave Band Center Frequency (Hz)
  • Page 29 MULTI/SINGLE Indoor unit Ceiling concealed duct - Middle static pressure 7. Sound levels 7.2 Sound power level Note 1. Operating condition • Power source : 220-240V 50 Hz / 220V 60 Hz • Cooling : Indoor temperature (27°C DB, 19°C WB), Outdoor temperature (35°C DB, 24°C WB) •...
  • Page 30 MULTI/SINGLE Indoor unit Ceiling concealed duct - Middle static pressure 7. Sound levels  External Static Pressure 4(39) [mmAq(Pa)] ABNW36GM2A0 [UM36 N24] NR-90 NR-85 NR-80 NR-75 NR-70 NR-65 NR-60 NR-55 NR-50 NR-45 NR-40 NR-35 NR-30 1000 2000 4000 8000 Octave Band Center Frequency (Hz) ...
  • Page 31 MULTI/SINGLE Indoor unit Ceiling concealed duct - Middle static pressure 7. Sound levels  External Static Pressure 4(39) [mmAq(Pa)] ABNW36GM2A0 [UM36 N24] NR-90 NR-85 NR-80 NR-75 NR-70 NR-65 NR-60 NR-55 NR-50 NR-45 NR-40 NR-35 NR-30 1000 2000 4000 8000 Octave Band Center Frequency (Hz) ...
  • Page 32 MULTI/SINGLE Indoor unit Ceiling concealed duct - Middle static pressure 8. Installation • Please read the instruction sheets completely before installing the product. • When the power cord is damaged, replacement work shall be performed by authorized personnel only. • Installation work must be performed in accordance with the national wiring standards. •...
  • Page 33 MULTI/SINGLE Indoor unit Ceiling concealed duct - Middle static pressure 8. Installation 2. Avoid installing air conditioner in such places where cooking oil or iron powder is generated. 3. Avoid places where inflammable gas is generated. 4. Avoid place where noxious gas is generated. 5.
  • Page 34 MULTI/SINGLE Indoor unit Ceiling concealed duct - Middle static pressure 8. Installation 8.2 Ceiling dimension and hanging bolt location CAUTION • During the installation, care should be taken not to damage electric wires. • In case of using a drain pump, install the unit horizontally using a level gauge. Ceiling Level gauge ※...
  • Page 35 MULTI/SINGLE Indoor unit Ceiling concealed duct - Middle static pressure 8. Installation Installation dimension of Indoor unit M1/M2/M3 Chassis Drain hole Dimension (mm) Chassis name 933.4 971.6 619.2 15.2 201.4 1283.4 1321.6 619.2 689.6 15.2 1208 201.4 1250 1283.4 1321.6 619.2 689.6 15.2...
  • Page 36 MULTI/SINGLE Indoor unit Ceiling concealed duct - Middle static pressure 8. Installation 8.3 Connecting pipes to the indoor unit Refrigerant piping work To detail information for connecting the refrigerant pipes, please refer to the installation manual included withproduct. Piping insulation work •...
  • Page 37 MULTI/SINGLE Indoor unit Ceiling concealed duct - Middle static pressure 8. Installation 8.4 Indoor Unit Drain Piping Important • The drain pipe should be at least equal in size to drain conduit of the indoor unit. • The drain pipe is thermally insulated to prevent the formation of condensation inside the pipe. •...
  • Page 38 MULTI/SINGLE Indoor unit Ceiling concealed duct - Middle static pressure 8. Installation – Heat insulation material: Polyethylene foam with thickness more than 8 mm (5/16 inch). Upward Thermal insulator Pipe clamp routing (Local supply) not allowed Drainage pipe Indoor unit (Local supply) Unit Maintenance...
  • Page 39 MULTI/SINGLE Indoor unit Ceiling concealed duct - Middle static pressure 8. Installation CAUTION – The supplied flexible drain hose should not be curved, neither screwed. The curved or screwed hose may cause a leakage of water. – It is need to insulate the auxiliary drain hose with thermal insulation material. 8.4.5 Ground drain piping •...
  • Page 40 MULTI/SINGLE Indoor unit Ceiling concealed duct - Middle static pressure 8. Installation 8.5 Electric wiring work 8.5.1 General instructions • All field supplied parts and materials, electric works must conform to local codes. Use copper wire only. • Follow the "WIRING DIAGRAM” attached to the unit body to wire the outdoor unit, indoor units and the remote controller.
  • Page 41 MULTI/SINGLE Indoor unit Ceiling concealed duct - Middle static pressure 8. Installation • When clamping the wires, be sure no pressure is applied to the wire connections by using the included clamping material to make appropriate clamps. Also, when wiring, make sure the cover on the electric parts box fits snugly by arranging the wires neatly and attaching the electric parts box cover firmly.