Quick Links

AIR CONDITIONER
DUCT TYPE
KEEP THIS MANUAL FOR FUTURE REFERENCE
BEWAHREN SIE DIESES HANDBUCH ZUM SPÄTEREN NACHSCHLAGEN AUF
CONSERVEZ CE MANUEL POUR RÉFÉRENCE ULTÉRIEURE
CONSERVE ESTE MANUAL PARA FUTURA REFERENCIA
CONSERVARE IL PRESENTE MANUALE PER FUTURE CONSULTAZIONI
ΦΥΛΑΞΤΕ ΤΟ ΕΓΧΕΙΡΙΔΙΟ ΓΙΑ ΜΕΛΛΟΝΤΙΚΗ ΑΝΑΦΟΡΑ
GUARDE ESTE MANUAL PARA REFERÊNCIA FUTURA
ХРАНИТЕ РУКОВОДСТВО ДЛЯ СПРАВОК В БУДУЩЕМ
BU KILAVUZU İLERİDE BAŞVURMAK ÜZERE SAKLAYIN
OPERATING MANUAL
BEDIENUNGSANLEITUNG
MANUAL DE FUNCIONAMIENTO
MANUALE DI ISTRUZIONI
ΕΓΧΕΙΡΙΔΙΟ ΛΕΙΤΟΥΡΓΙΑΣ
MANUAL DE FUNCIONAMENTO
РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ
KULLANIM KILAVUZU
MODE D'EMPLOI
[Original instructions]
PART No. 9374379569-03
Table of Contents
loading

Summary of Contents for Fujitsu ACY71UIA-LM

  • Page 1 AIR CONDITIONER OPERATING MANUAL BEDIENUNGSANLEITUNG DUCT TYPE MODE D’EMPLOI MANUAL DE FUNCIONAMIENTO MANUALE DI ISTRUZIONI ΕΓΧΕΙΡΙΔΙΟ ΛΕΙΤΟΥΡΓΙΑΣ MANUAL DE FUNCIONAMENTO РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ KULLANIM KILAVUZU KEEP THIS MANUAL FOR FUTURE REFERENCE BEWAHREN SIE DIESES HANDBUCH ZUM SPÄTEREN NACHSCHLAGEN AUF CONSERVEZ CE MANUEL POUR RÉFÉRENCE ULTÉRIEURE CONSERVE ESTE MANUAL PARA FUTURA REFERENCIA CONSERVARE IL PRESENTE MANUALE PER FUTURE CONSULTAZIONI ΦΥΛΑΞΤΕ...
  • Page 2: Table Of Contents

    OPERATING MANUAL PART No. 9374379569-03 AIR CONDITIONER (DUCT TYPE) CONTENTS WEEKLY TIMER ............9 SAFETY PRECAUTIONS ........2 TEMPERATURE SET BACK TIMER ......11 FEATURES AND FUNCTIONS ....... 3 ECONOMY OPERATION ........12 NAME OF PARTS ........... 4 CLEANING AND CARE ......... 12 PREPARATORY OPERATION ........
  • Page 3: Features And Functions

    FEATURES AND FUNCTIONS n Energy saving and Comfortable function n Remote controller WIRED REMOTE CONTROLLER INVERTER At the start of operation, large amount of power is used to The wired remote controller allows convenient control of indoor bring the room quickly to the desired temperature. Afterwards, unit operation.
  • Page 4: Name Of Parts

    NAME OF PARTS Remote controller 1 START/STOP button C Horizontal airfl ow direction and 2 SET TEMP. (temperature) button Swing button 3 MODE button D MAINTENANCE (FILTER RESET) 4 FAN button button 5 ECONOMY button E Operation lamp 6 TIMER MODE F Timer and Clock indicator (CLOCK ADJUST) button G Operation mode indicator...
  • Page 5: Preparatory Operation

    PREPARATORY OPERATION Set the current day and time Press the DAY button and select the current day. appears around the selected day. Press the TIMER MODE (CLOCK ADJUST) button for 2 seconds or more. The time indicator on the remote controller will fl ash. Press the SET TIME (<...
  • Page 6: Operation

    OPERATION Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). To start/stop operation Press the START/STOP button. Operation lamp Air conditioner ON: Lit brightly Air conditioner OFF: Not lit To set the operation mode Operation mode setting Press the MODE button to set the operation mode.
  • Page 7 OPERATION Room temperature sensor selection This function is locked at the factory. In order to detect the room temperature correctly, consult authorized ser- • vice personnel when using this function. Indoor unit Press the ECONOMY button for more than 2 seconds to select whether the room temperature is detected at the indoor unit or the remote controller.
  • Page 8: Timer Functions

    TIMER FUNCTIONS OFF timer (See page 8.) Use this timer function to stop air conditioner operation. The timer operates and air conditioner operation stops after the set time has passed. The timer can be set up to 24 hours in advance. ON timer (See page 8.) Use this timer function to start air conditioner operation.
  • Page 9: Weekly Timer

    WEEKLY TIMER Note: In simultaneous multi connection, this function by using the wireless remote controller cannot be used. Weekly timer setting Press the TIMER SET button for Press the TIMER MODE button to select the weekly timer. 2 seconds or more. Day of the week setting Press the DAY button to select the day of the week, and then press the TIMER SET button to confi...
  • Page 10 WEEKLY TIMER Note: In simultaneous multi connection, this function by using the wireless remote controller cannot be used. WEEKLY timer operation To start To cancel When the weekly timer is selected, the • Press the TIMER DELETE button to ex. Operating time 7:00-18:00 timer starts automatically.
  • Page 11: Temperature Set Back Timer

    TEMPERATURE SET BACK TIMER Note: In simultaneous multi connection, this function by using the wireless remote controller cannot be used. Temperature SET BACK timer setting If there is no existing SET BACK SET BACK tempera- ture setting, “- -” will be displayed for the temperature.
  • Page 12: Economy Operation

    ECONOMY OPERATION Begin air conditioner operation before performing this procedure. To Use the ECONOMY Operation Press the ECONOMY button. The ECONOMY indicator will light. ECONOMY operation begins. To Stop the ECONOMY Operation Press the ECONOMY button again. The ECONOMY indicator will go out. Normal operation begins.
  • Page 13: Troubleshooting

    TROUBLESHOOTING Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). In following events, immediately stop operation of the air conditioner, and disconnect all the power WARNING supply by turning off the electrical breaker or disconnecting the power plug. Then consult your dealer or authorized service personnel.
  • Page 14 TROUBLESHOOTING Symptom Items to check See Page CHECK ONCE Does not operate at all: Has the circuit breaker been turned off? MORE — Has there been a power failure? Has a fuse blown out, or a circuit breaker been tripped? Is the timer operating? 8 to 10 Poor cooling (or heating*)
  • Page 15: Operating Tips

    OPERATING TIPS Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). Heating Performance* Low Ambient Cooling This air conditioner operates on the heat-pump principle, When the outdoor temperature drops, the outdoor unit’s fans may absorbing heat from outdoor air and transferring that heat switch to low speed, or one of the fans may stop intermittently.
  • Page 16 OPERATING TIPS Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). Mode Operation AUTO (in COOLING model): When AUTO (automatic changeover) operation fi rst selected, the fan will operate at very low speed for about a few minutes, during which time the indoor unit detects the room conditions and selects the proper mode.
  • Page 17: Self-Diagnosis

    OPERATING TIPS Instructions relating to inverter ( ) are applicable only to “INVERTER MODEL”. AUTO Restart In Event of Power Interruption Should the power supply to the air conditioner be interrupted Use of other electrical appliances (electric shaver, etc.) or by a power failure, the air conditioner will restart automatically nearby use of a wireless radio transmitter may cause the air in the previously selected mode once the power is restored.