Quick Links

AIR CONDITIONER
OPERATING MANUAL
BEDIENUNGSANLEITUNG
DUCT TYPE
MODE D'EMPLOI
MANUAL DE FUNCIONAMIENTO
MANUALE DI ISTRUZIONI
ΕΓXΕΙΡΙ∆ΙO ΛΕΙΤOΥΡΓΙΑΣ
MANUAL DE FUNCIONAMENTO
РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ
KULLANMA KİTABI
使用說明書
KEEP THIS MANUAL FOR FUTURE REFERENCE
BEWAHREN SIE DIESES HANDBUCH ZUM SPÄTEREN NACHSCHLAGEN AUF
CONSERVEZ CE MANUEL POUR RÉFÉRENCE ULTÉRIEURE
CONSERVE ESTE MANUAL PARA SU FUTURA CONSULTA
CONSERVARE IL PRESENTE MANUALE PER FUTURE CONSULTAZIONI
ΦΥΛΑΞΤΕ ΤΟ ΕΓΧΕΙΡΙΔΙΟ ΓΙΑ ΜΕΛΛΟΝΤΙΚΗ ΑΝΑΦΟΡΑ
GUARDE ESTE MANUAL PARA CONSULTA FUTURA
РУКОВОДСТВО ДЛЯ СПРАВОК В БУДУЩЕМ
BU KILAVUZU, DAHA SONRA BAŞVURMAK ÜZERE SAKLAYIN
PART NO. 9374379552-02
Table of Contents
loading

Summary of Contents for Fujitsu ACY140UI-LH

  • Page 1 AIR CONDITIONER OPERATING MANUAL BEDIENUNGSANLEITUNG DUCT TYPE MODE D’EMPLOI MANUAL DE FUNCIONAMIENTO MANUALE DI ISTRUZIONI ΕΓXΕΙΡΙ∆ΙO ΛΕΙΤOΥΡΓΙΑΣ MANUAL DE FUNCIONAMENTO РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ KULLANMA KİTABI 使用說明書 KEEP THIS MANUAL FOR FUTURE REFERENCE BEWAHREN SIE DIESES HANDBUCH ZUM SPÄTEREN NACHSCHLAGEN AUF CONSERVEZ CE MANUEL POUR RÉFÉRENCE ULTÉRIEURE CONSERVE ESTE MANUAL PARA SU FUTURA CONSULTA CONSERVARE IL PRESENTE MANUALE PER FUTURE CONSULTAZIONI...
  • Page 2: Table Of Contents

    CONTENTS WEEKLY TIMER ............9 SAFETY PRECAUTIONS ........2 TEMPERATURE SET BACK TIMER ......11 FEATURES AND FUNCTIONS ....... 3 ECONOMY OPERATION ........12 NAME OF PARTS ........... 4 CLEANING AND CARE ......... 12 PREPARATORY OPERATION ........ 5 TROUBLESHOOTING .......... 13 OPERATION ............
  • Page 3: Features And Functions

    SAFETY PRECAUTIONS This appliance is not intended for use by persons (including children) with reduced ● CAUTION physical, sensory or mental capabilities, or lack of experience and knowledge, un- less they have been given supervision or instruction concerning use of the appli- ance by a person responsible for their safety.
  • Page 4: Name Of Parts

    NAME OF PARTS Remote controller 1 START/STOP button C Horizontal airfl ow direction and 2 SET TEMP. (temperature) button Swing button 3 MODE button D MAINTENANCE (FILTER RESET) 4 FAN button button 5 ECONOMY button E Operation lamp 6 TIMER MODE (CLOCK AD- F Timer and Clock indicator G Operation mode indicator JUST) button...
  • Page 5: Preparatory Operation

    PREPARATORY OPERATION Set the current day and time Press the DAY button and select the current day. appears around the selected day. Press the TIMER MODE (CLOCK ADJUST) button for 2 seconds or more. The time indicator on the remote controller will fl ash. Press the SET TIME (<...
  • Page 6: Operation

    OPERATION Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). To start/stop operation Press the START/STOP button. Operation lamp Air conditioner ON: Lit brightly Air conditioner OFF: Not lit To set the operation mode Operation mode setting ●...
  • Page 7 OPERATION Room temperature sensor selection This function is locked at the factory. In order to detect the room temperature correctly, consult authorized ser- • vice personnel when using this function. Indoor unit Press the ECONOMY button for more than 2 seconds to select whether the room temperature is detected at the indoor unit or the remote controller.
  • Page 8: Timer Functions

    TIMER FUNCTIONS OFF timer (See page 8.) Use this timer function to stop air conditioner operation. The timer operates and air conditioner operation stops after the set time has passed. The timer can be set up to 24 hours in advance. ON timer (See page 8.) Use this timer function to start air conditioner operation.
  • Page 9: Weekly Timer

    WEEKLY TIMER Weekly timer setting Press the TIMER SET button for Press the TIMER MODE button to select the weekly timer. 2 seconds or more. Day of the week setting ● Press the DAY button to select the day of the week, and then press the TIMER SET button to confi...
  • Page 10 WEEKLY TIMER WEEKLY timer operation To start To cancel ● ● When the weekly timer is selected, the Press the TIMER DELETE button to • ex. Operating time 7:00-18:00 timer starts automatically. cancel the timer mode. The timer mode can also be •...
  • Page 11: Temperature Set Back Timer

    TEMPERATURE SET BACK TIMER Temperature SET BACK timer setting If there is no existing SET BACK SET BACK tempera- ture setting, “- -” will be displayed for the temperature. Press the SET BACK button to change to the SET BACK con- Press the TIMER SET button for 2 seconds or more.
  • Page 12: Economy Operation

    ECONOMY OPERATION Begin air conditioner operation before performing this procedure. To Use the ECONOMY Operation Press the ECONOMY button. The ECONOMY indicator will light. ECONOMY operation begins. To Stop the ECONOMY Operation Press the ECONOMY button again. The ECONOMY indicator will go out. Normal operation begins.
  • Page 13: Troubleshooting

    TROUBLESHOOTING Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). In the event of a malfunction (burning smell, etc.), immediately stop operation, turn off the electrical WARNING breaker, and consult authorized service personnel. Merely turning off the unit’s power switch will not completely disconnect the unit from the power source. Always be sure to turn off the electrical breaker to ensure that power is completely off.
  • Page 14: Operating Tips

    OPERATING TIPS Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). Heating Performance* Microcomputer-controlled Automatic Defrosting* This air conditioner operates on the heat-pump principle, ● absorbing heat from outdoor air and transferring that heat When using the heating mode under conditions of low outdoor ●...
  • Page 15 OPERATING TIPS Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). Mode Operation AUTO (in COOLING model): When AUTO (automatic changeover) operation fi rst selected, the fan will operate at very low speed for about a few ●...
  • Page 16: Self-Diagnosis

    OPERATING TIPS Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). AUTO Restart In Event of Power Interruption Should the power supply to the air conditioner be interrupted Use of other electrical appliances (electric shaver, etc.) or ●...