Quick Links

Table of Contents
loading

Summary of Contents for Siemens LC91BE542

  • Page 2: Table Of Contents

    Attaching the flue duct............... 15 INSTRUCTION MANUAL Produktinfo Additional information on products, accessories, replacement parts and services can be found at www.siemens-home.com and in the online shop www.siemens-eshop.com : Important safety information Read these instructions carefully. Only then This appliance may be used by children...
  • Page 3 Danger of suffocation! Risk of fire! Packaging material is dangerous to Grease deposits in the grease filter may ■ children. Never allow children to play with catch fire. packaging material. Clean the grease filter at least every Danger of death! 2 months.
  • Page 4: Environmental Protection

    Risk of electric shock! Causes of damage A defective appliance may cause electric Caution! ■ shock. Never switch on a defective Risk of damage due to corrosion. Always switch on the appliance. Unplug the appliance from the appliance while cooking to avoid condensation. Condensate can produce corrosion damage.
  • Page 5: Operation

    Operation Lighting These instructions apply to several appliance variants. It is possible that individual features are described which do not The lighting can be switched on and off independently of the apply to your appliance. fan. Note: Switch on the extractor hood when you start cooking and Press the button.
  • Page 6: Control Panel Model 2

    Control panel model 2 Lighting The lighting can be switched on and off independently of the Control panel fan. Press the button. Setting the brightness Press and hold the button until the desired brightness is reached. Explanation Fan on/off Saturation display Light on/off/dimming When the metal mesh grease filters or the activated carbon filter are saturated, a signal sounds for approx.
  • Page 7: Control Panel Model 3

    Control panel model 3 Sensor control In automatic mode, a sensor in the extractor hood detects the Control panel intensity of the cooking and roasting fumes. Depending on the setting of the sensor, the fan automatically switches to another fan setting. Default sensitivity setting: †...
  • Page 8: Cleaning And Maintenance

    Cleaning and maintenance Cleaning the metal mesh grease filters Risk of burns! The appliance will become hot during operation, especially Risk of fire! near the bulbs. Allow the appliance to cool down before Grease deposits in the grease filter may catch fire. cleaning.
  • Page 9: Trouble Shooting

    Removing metal mesh grease filter For additional filters, open the lock and fold down the metal grease filter. While doing this, place the other hand under the Open the lock and fold down the metal grease filter. While metal grease filter. doing this, place the other hand under the metal grease filter.
  • Page 10: After-Sales Service

    After-sales service Our after-sales service is there for you if your appliance needs Basic equipment: Starter set for circulating-air mode - wide to be repaired. We will always find the right solution in order to avoid unnecessary visits from a service technician. When calling us, please give the product number (E no.) and the production number (FD no.) so that we can provide you with the correct advice.
  • Page 11: Installation Instructions

    INSTALLATION INSTRUCTIONS Installation instructions This appliance is installed on the wall. ■ Follow the enclosed installation instructions for additional ■ special accessories (e.g. for circulating-air mode). The surfaces of the appliance are sensitive. Avoid damaging ■ them during installation. : Important safety information Read these instructions carefully.
  • Page 12 Danger of death! Risk of poisoning from flue gases that are drawn back in. If installing a ventilation system in a room with a heat-producing appliance connected to a chimney/flue, the electricity supply to the hood must be Room air-dependent heat-producing equipped with a suitable safety switch.
  • Page 13: General Information

    General information Exhaust air mode Checking the wall The wall must be level, vertical and adequately load-bearing. ■ Risk of death! The depth of the bore holes must be the same length as the Risk of poisoning from flue gases that are drawn back in. The ■...
  • Page 14: Installation

    Installation Attaching and aligning the appliance Screw on the fixing bracket for the flue duct. Initially remove the protective foil from the back of the ¨ appliance and, following installation, remove the foil completely. When attaching the appliance, ensure that it engages firmly with the brackets.
  • Page 15: Attaching The Flue Duct

    Attaching the flue duct Removing the safety caps If the safety caps must be removed, use a flat screwdriver. Risk of injury! From sharp edges during installation. Always wear protective gloves while installing the appliance. Separate the flue ducts. To do this, remove the adhesive tape. Remove the protective foil from both flue ducts.
  • Page 16 Siemens-Electrogeräte GmbH Carl-Wery-Straße 34 81739 München Germany *9000852563* 9000852563 940210...

This manual is also suitable for:

Iq500Lc98wa542Lc91bb542

Table of Contents