  • Page 1 Preface Introduction Installation SIMATIC NET Maintenance and cleaning Network components 12M bus terminal Technical specifications Approvals Operating Instructions 06/2022 C79000-G8976-C333-02...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Preface

    You will find information on the use of this product in the following sources: • in the product documentation • in the SIMATIC NET PROFIBUS Networks manual The manual is available on the Internet pages of Siemens Industry Online Support under the following entry ID: 35222591 (http://support.automation.siemens.com/WW/view/en/35222591) •...
  • Page 4 (https://www.siemens.com/cert). Device defective If a fault develops, send the device to your SIEMENS representative for repair. Repairs on-site are not possible. Recycling and disposal The products are low in pollutants, can be recycled and meet the requirements of the WEEE directive 2012/19/EU for the disposal of electrical and electronic equipment.
  • Page 5: Table Of Contents

    Table of contents Preface ..............................3 Introduction ............................7 Included in shipment ......................7 Description of the product....................7 Compatible devices ......................10 Installation............................11 Important notes on using the device .................. 11 Mounting and attaching the bus cable(s) ................15 Grounding measures......................
  • Page 6 Table of contents 12M bus terminal Operating Instructions, 06/2022, C79000-G8976-C333-02...
  • Page 7: Introduction

    Introduction Included in shipment • 12M bus terminal order no. 6GK1 500-0AA10 Description of the product Function The 12M bus terminal is used to attach data terminal equipment (DTE) with an RS-485 interface to a bus cable. Note A maximum of 32 12M bus terminals can be connected to one bus segment. If other components, such as repeaters are connected to a bus segment, this reduces the maximum number of 12M bus terminals that can be connected.
  • Page 8 Introduction 1.2 Description of the product • 2 switches: – right-hand switch ("Termination") With the right-hand switch, you can terminate the end of an incoming, electrical segment (A1, B1) with the characteristic impedance (switch on). At the same time, the outgoing, electrical segment (A2, B2) is interrupted.
  • Page 9 Introduction 1.2 Description of the product D-sub male connector The D-sub male connector is plugged into the D-sub female connector of the DTE and secured by screws. The 12M bus terminal requires a current of 90 mA with a voltage of 5 V supplied by the DTE between pins 5 (M5) and 6 (P5) of the D-sub male connector.
  • Page 10: Compatible Devices

    Introduction 1.3 Compatible devices Compatible devices Table 1-1 Connectable devices that can supply 90 mA at 5V. Name Master slave Comments BT12M can be used SIMATIC S5 IM 308-C M + S CP 5431 FMS/DP S5-95U/DP M + S SIMATIC S7-200 CPU 215-DP CP 242-8 SIMATIC S7-300...
  • Page 11: Installation

    Installation CAUTION To prevent injury and damage, read the manual before using the device. Important notes on using the device Read the safety notices Note the following safety notices. These relate to the entire working life of the device. WARNING Power supply The device is designed for operation with a directly connectable safety extra low voltage (SELV) from a limited power source (LPS).
  • Page 12 Installation 2.1 Important notes on using the device NOTICE Improper mounting Improper mounting may damage the device or impair its operation. • Before mounting the device, always ensure that there is no visible damage to the device. • Mount the device using suitable tools. Observe the information in the respective section about mounting.
  • Page 13 Installation 2.1 Important notes on using the device WARNING Unsuitable cables or connectors Risk of explosion in hazardous areas • Only use connectors that meet the requirements of the relevant type of protection. • If necessary, tighten the connector screw connections, device fastening screws, grounding screws, etc.
  • Page 14 Installation 2.1 Important notes on using the device Notes for use in hazardous locations according to ATEX, IECEx, UKEX and CCC Ex If you use the device under ATEX, IECEx, UKEX or CCC Ex conditions you must also keep to the following safety instructions in addition to the general safety instructions for protection against explosion: WARNING...
  • Page 15: Mounting And Attaching The Bus Cable(S)

    Installation 2.2 Mounting and attaching the bus cable(s) Mounting and attaching the bus cable(s) Installation Types of installation The 12M bus terminal can be mounted in three different ways: • By snapping it on to a 35 mm DIN rail according to DIN EN50022-35x7.5 •...
  • Page 16 Installation 2.2 Mounting and attaching the bus cable(s) 3. Shorten the braided shield and foil shield to a length of approximately 12 mm (the foil shield can be left somewhat longer) and shorten the two fillers to a length of approximately 12 mm. ①...
  • Page 17 Installation 2.2 Mounting and attaching the bus cable(s) Note The 12M bus terminal may only be plugged into a PROFIBUS interface when the power is off. The following scheme is recommended for a PROFIBUS LAN: • Connector A: green wire •...
  • Page 18: Grounding Measures

    Installation 2.3 Grounding measures Grounding measures If the 12M bus terminal is mounted on a DIN rail, the shield clamp makes largearea contact with the rail via an internal spring. To connect the cable shield with local ground, a connection between the DIN rail to local earth is adequate (this should be kept as short as possible).
  • Page 19: Disassembly

    Installation 2.4 Disassembly Note The DIN rail must have a good conducting surface. Note If you mount the bus terminal on a wall, connect at least one PE terminal to local ground. This connection should be over the shortest possible distance. Disassembly WARNING Improper disassembly...
  • Page 20 Installation 2.4 Disassembly 12M bus terminal Operating Instructions, 06/2022, C79000-G8976-C333-02...
  • Page 21: Maintenance And Cleaning

    Maintenance and cleaning WARNING Unauthorized repair of devices in explosion-proof design Risk of explosion in hazardous areas • Repair work may only be performed by personnel authorized by Siemens. WARNING Impermissible accessories and spare parts Risk of explosion in hazardous areas •...
  • Page 22 Maintenance and cleaning 12M bus terminal Operating Instructions, 06/2022, C79000-G8976-C333-02...
  • Page 23: Technical Specifications

    1.5 Mbps along with RS485 bus terminal. You will find more information on the weighting factor in the "SIMATIC NET PROFIBUS Network" manual on the Internet pages of Siemens Industry Online Support under the following entry ID: 35222591 (http://support.automation.siemens.com/WW/view/en/35222591).
  • Page 24 Technical specifications Mechanical conditions Vibration tested to DIN IEC 68-2-6 Operation 10 ... 58 Hz; amplitude 0.075 mm 58 ... 500 Hz; acceleration 9.8 m/s Shock tested to DIN IEC 68-2-27 Operation Half-sine: 100 m/s , 16 ms Construction Dimensions (W x H x D) 50 x 135 x 47 mm Spur line length 1.5 m...
  • Page 25: Approvals

    Certificates for shipbuilding and national approvals The device certificates for shipbuilding and special national approvals can be found on the pages of Siemens Automation Customer Support under the following entry ID: 57337426 (http:// support.automation.siemens.com/WW/view/en/57337426). Under this entry, go to the required product and select the following settings: "Entry list" tab >...
  • Page 26 DE-76181 Karlsruhe Germany Importer UK: Siemens plc, Manchester M20 2UR You can find the current UK Declaration of Conformity for these products on the Internet pages under Siemens Industry Online Support (https://support.industry.siemens.com/cs/ww/en/ps/ 15273/cert). 12M bus terminal Operating Instructions, 06/2022, C79000-G8976-C333-02...
  • Page 27 You will find this document • on the data medium that ships with some devices. • on the Internet pages under Siemens Industry Online Support. Enter the document identification number "C234" as the search term. The markings of the electrical devices are:...
  • Page 28: Note For Australia

    Approvals 5.1 Note for Australia EMC (electromagnetic compatibility) The SIMATIC NET products described in these operating instructions meet the electromagnetic compatibility requirements according to the EU Directive 2014/30/EU as well as the UK- Regulation SI 2016/1091 and their associated amendments. Applied standards: •...
  • Page 29 • "Industrial Ethernet / PROFINET Industrial Ethernet" System Manual (https:// support.industry.siemens.com/cs/ww/en/view/27069465) • "Industrial Ethernet / PROFINET - Passive Network Components" System Manual (https:// support.industry.siemens.com/cs/ww/en/view/84922825) • "EMC Installation Guidelines" configuration manual (https:// support.industry.siemens.com/cs/ww/en/view/60612658)
  • Page 30 Approvals 5.1 Note for Australia WARNING Personal injury and property damage can occur The installation of expansions that are not approved for SIMATIC NET products or their target systems may violate the requirements and regulations for safety and electromagnetic compatibility. Only use expansions that are approved for the system.