Thermistor Resistance Values; Indoor Unit - Fujitsu ASUH18LMAS Service Manual

Wall mounted type
Hide thumbs Also See for ASUH18LMAS:
Table of Contents

6. Thermistor resistance values

6-1. Indoor unit

¢ Room temperature thermistor
Temperature °F (°C)
14.0 (-10.0)
23.0 (-5.0)
32.0 (0.0)
41.0 (5.0)
50.0 (10.0)
59.0 (15.0)
68.0 (20.0)
77.0 (25.0)
86.0 (30.0)
95.0 (35.0)
104.0 (40.0)
113.0 (45.0)
¢ Heat exchanger temperature thermistor
Temperature °F (°C)
-22.0 (-30.0)
-13.0 (-25.0)
-4.0 (-20.0)
5.0 (-15.0)
14.0 (-10.0)
23.0 (-5.0)
32.0 (0.0)
41.0 (5.0)
50.0 (10.0)
59.0 (15.0)
68.0 (20.0)
77.0 (25.0)
86.0 (30.0)
95.0 (35.0)
104.0 (40.0)
113.0 (45.0)
122.0 (50.0)
131.0 (55.0)
140.0 (60.0)
149.0 (65.0)
6-1. Indoor unit
Resistance (kΩ)
58.25
44.03
33.62
25.93
20.18
15.84
12.54
10.00
8.04
6.51
5.30
4.35
Resistance (kΩ)
1,131.91
804.52
579.59
422.89
312.27
233.21
176.03
134.23
103.34
80.28
62.91
49.70
39.57
31.74
25.64
20.85
17.06
14.05
11.64
9.69
- (03-88) -
Voltage (V)
0.73
0.93
1.15
1.39
1.66
1.94
2.22
2.50
2.77
3.03
3.27
3.49
Voltage (V)
0.21
0.29
0.40
0.53
0.69
0.88
1.10
1.36
1.63
1.92
2.21
2.51
2.79
3.06
3.30
3.53
3.73
3.90
4.05
4.19
6. Thermistor resistance values