GE T1 Multiplexer Installation Manual

GE T1 Multiplexer Installation Manual

Junglemux sonet multiplexer

Quick Links

3 3 4 4 2 2 - - 8 8 6 6 4 4 0 0 0 0 - - 4 4 3 3 1 1 P P S S
I I s s s s u u e e 2 2 . . 1 1
M M a a r r c c h h 2 2 0 0 1 1 3 3
JungleMUX SONET Multiplexer
T1 Multiplexer (T1MX)
86431 POWER UNIT
Technical Practice
and
Installation Manual
Copyright © GE Multilin Inc. 2001-2013
Table of Contents
loading

Summary of Contents for GE T1 Multiplexer

  • Page 1 I I s s s s u u e e 2 2 . . 1 1 M M a a r r c c h h 2 2 0 0 1 1 3 3 JungleMUX SONET Multiplexer T1 Multiplexer (T1MX) 86431 POWER UNIT Technical Practice Installation Manual Copyright © GE Multilin Inc. 2001-2013...
  • Page 2 GE Multilin Inc. reserves the right to make changes and modifications to any part of this document without notice. GE Multilin Inc. is not responsible for any damages or losses incurred as a result of out-of-date or incorrect information contained in this document.
  • Page 3: Table Of Contents

    B86431-4X Power Unit ................10 5. INSTALLATION ..........14 Pre-installation ..................14 Shelf Position ..................14 Power Requirements ................15 Inserting the Unit in the Shelf ............16 Removing the Unit from the Shelf .............16 Paddleboard Connections ..............17 Paddleboard Installation ..............18 Copyright  GE Multilin Inc. 2001-2013...
  • Page 4: Section Page

    7. SPECIFICATIONS ..........20 8. ORDERING INFORMATION ......22 Equipment and Option Code List ............22 APPENDIX A ............23 List of Figures ..................23 List of Tables ..................23 APPENDIX B ............24 List of Acronyms .................24 Copyright  GE Multilin Inc. 2001-2013...
  • Page 5: Introduction

    March 2013 Page 5 1. INTRODUCTION The 86431 Power Unit is one of the family of units in the GE Multilin’s JungleMUX SONET and T1 Multiplexer (T1MX) digital transport/access systems designed specifically for the requirements of the utility (Power, Transportation, Pipelines, Oil &...
  • Page 6: Handling And Packing

    The following Electronic Industries Association (EIA) attention label appears on all GE Multilin EAS schematics and should be attached on all containers used for ESDS items to alert personnel that the contents requires special handling. ATTENTION...
  • Page 7: Unit Overview

    18 W while the new-generation B86431-4X Power Units can sustain a maximum load of 30 W on permanent basis. The (B)86431-0X and B86431-4X units are compatible and can be paralleled along the same power bus. Copyright  GE Multilin Inc. 2001-2013...
  • Page 8: Front Panel Layout

    As the name implies, it allows for easy extraction of the unit from the shelf. WARNING Do not use the extractor to force the unit into the shelf as this could result in damage to the extractor. Copyright  GE Multilin Inc. 2001-2013...
  • Page 9: B86431-4X Power Unit

    As the name implies, it allows for easy extraction of the unit from the shelf. WARNING Do not use the extractor to force the unit into the shelf as this could result in damage to the extractor. Copyright  GE Multilin Inc. 2001-2013...
  • Page 10: Unit Description

    J1(A12, C12) and shelf ground on J1(A13, C13). The NO contact is available on all versions of the 86431-90 Power Unit paddleboard. The NC contact was available on 86431-90 paddleboard versions MS ISS 91X and MS ISS 1. Copyright  GE Multilin Inc. 2001-2013...
  • Page 11 Red LED and turn the Form-A contact into alarm state. The converter module can then be reset only by power cycling the unit; however, the unit must remain unplugged from the shelf for at least 2 seconds. Copyright  GE Multilin Inc. 2001-2013...
  • Page 12: Figure 3: (B)86431-0X Power Unit Block Diagram

    1) REFER TO UNIT EAS-86431-M1 FOR COMPLETE SCHEMATIC. POWER UNIT 2) NORMALLY CLOSED CONTACT (J1 PIN C11) WAS EXPOSED ON 86431-0X 86431-90 PADDLEBOARDS MS ISS 91X AND MS ISS 1. Figure 3: (B)86431-0X Power Unit Block Diagram Copyright  GE Multilin Inc. 2001-2013...
  • Page 13: Figure 4: B86431-4X Power Unit Block Diagram

    A1-4 C1-4 P/O 86431-90 P/B – TO POWER ALARM TO STATION BATTERY CIRCUIT GE Multilin BLOCK DIAGRAM POWER UNIT B86431-4X NOTE: REFER TO EAS-86431-4X FOR COMPLETE SCHEMATIC. Figure 4: B86431-4X Power Unit Block Diagram Copyright  GE Multilin Inc. 2001-2013...
  • Page 14: Installation

    B86431-4X units) is in Normal position and the screws are in place and firmly tightened. Keep the shipping containers and packing materials for future use. If a unit is damaged, file a claim with the shipping agent or the local GE Multilin representative.
  • Page 15: Power Requirements

    Input power for the unit is made on the paddleboard TB1. Input voltage level is dependent on unit option and can be either from a floating or grounded supply. Refer to the Equipment Option Code Table. Copyright  GE Multilin Inc. 2001-2013...
  • Page 16: Inserting The Unit In The Shelf

    4. (Applicable to (B)86431-0X units only!) Install the fuse through the opening on the front panel. Removing the Unit from the Shelf 1. Pull the extractor to remove the unit from the shelf. Copyright  GE Multilin Inc. 2001-2013...
  • Page 17: Paddleboard Connections

    AT T1MX NODES: TO POWER MONITOR PINS NC 1 ON CDAX PADDLEBOARD 86485-80/-95. NOT OPERATIONAL WHEN USED WITH B86431-4X POWER UNIT. + 5 VOLT MONITOR POINT MS ISS Figure 6: 86431-90 (MS ISS # 91X, MS 1) Paddleboard Connections Copyright  GE Multilin Inc. 2001-2013...
  • Page 18: Paddleboard Installation

    1. Place the paddleboard onto designated slot position ensuring that the rear connectors are fully mated. Ensure correct orientation of the paddleboard prior to insertion. 2. Secure the paddleboard in position using the fixing screws provided. Copyright  GE Multilin Inc. 2001-2013...
  • Page 19: Maintenance And Troubleshooting

    If an 86431 Power Unit is suspected of being defective, replace it with a known- good 86431 Power Unit and if the replacement unit functions properly, return the original to GE Multilin for repair or replacement. Note: An old-generation (B)86431-0X Power Unit can be replaced with a new- generation B86431-4X Power Unit and vice versa as long as they have the same external voltage rating (digit X must be the same).
  • Page 20: Specifications

    15,000 m (50,000 ft) Mechanical Vibration per MIL-STD 810E Bench Handling per TS 1-00446.06 EMI/RFI Meets ANSI/IEEE C37.90.2 RFI Isolation Meets ANSI/IEEE C37.90.1 SWC Reliability per TR-NWT-000332 800,000 Hours Table 2: (B)86431-0X Power Unit Specifications Copyright  GE Multilin Inc. 2001-2013...
  • Page 21: Table 3: B86431-4X Power Unit Specifications

    15,000 m (50,000 ft) Mechanical Vibration per MIL-STD 810E Bench Handling per TS 1-00446.06 EMI/RFI Meets ANSI/IEEE C37.90.2 RFI Isolation Meets ANSI/IEEE C37.90.1 SWC Reliability per TR-NWT-000332 700,000 Hours Table 3: B86431-4X Power Unit Specifications Copyright  GE Multilin Inc. 2001-2013...
  • Page 22: Ordering Information

    30W of power on permanent basis. Black faceplate. One 86431-90 paddleboard required for each unit. Same as -41 but operates from 48 V battery. B86431 Paddleboard Assembly. Provides external 86431 customer connections. Table 4: Equipment and Option Code Table Copyright  GE Multilin Inc. 2001-2013...
  • Page 23: List Of Figures

    TABLE DESCRIPTION PAGE Table 1: Troubleshooting Table ..............19 Table 2: (B)86431-0X Power Unit Specifications ......... 20 Table 3: B86431-4X Power Unit Specifications ..........21 Table 4: Equipment and Option Code Table ..........22 Copyright  GE Multilin Inc. 2001-2013...
  • Page 24: List Of Acronyms

    Mean Time Between Failures  Node Assignment Drawing  Normally Closed  Normally Open  Paddleboard  Radio Frequency Interference  SONET Synchronous Optical Network  Surge Withstand Capability  TPIM Technical Practice and Installation Manual Copyright  GE Multilin Inc. 2001-2013...

This manual is also suitable for:

T1mx86431