Page 7
Precaution For the customers in Europe If this unit is installed incorrectly, personal injury or damage This product with the CE marking complies with the EMC to peripheral items may occur due to fire, shock, or other Directive (89/336/EEC) issued by the Commission of the accidental circumstances.
Page 8
Table of Contents Overview ..................... 3 (E) Functions of the BKPF-292 .............3 (E) Parts Identifications of the Connector Panel ........4 (E) Specifications ..................5 (E) 2(E)
2-channel AES/EBU digital audio signals. The input level, delay and channel exchange, output phase inversion, and mix adjustments are applied to The BKPF-292 is designed to be installed and operated the input signals to output. in a PFV-D-series digital video interface unit. The...
The upper connector of each pair is for channels 1/2 and the lower one is for channels 3/4. REMOTE REMOTE connector (BNC type) To connect to an S-BUS (PN) communication network. Use a commercially BKPF-292 available T-bridge and coaxial cables (BELDEN8281 or equivalents) for connection. 4(E)
Specifications General Control functions Operating temperature Audio level ±6 dB/±12 dB/+6 dB to –∞/+12 5°C to 40°C (41°F to 104°F) dB to –∞ (The variable range is Storage temperature selected with an internal switch.) –20°C to +60°C Input channel selection (–4°F to +140°F) 4 inputs/4 outputs Operating humidity 10% to 90%...
Page 13
The material contained in this manual consists of information that is the property of Sony Corporation and is intended solely for use by the purchasers of the equipment described in this manual. Sony Corporation expressly prohibits the duplication of any...