Electrical Characteristics - Fujitsu ASUH18LMAS Design & Technical Manual

Hide thumbs Also See for ASUH18LMAS:
Table of Contents

10. Electrical characteristics

Model name
Voltage
Power supply
Frequency
1
MCA *
Starting current
MAX. CKT. BKR *
Power cable
Wiring spec.
2
*
Connection
cable *
1
*
: Minimum Circuit Ampacity (Calculation based on UL60335-2-40)
2
*
: Selected sample based on Japan Electrotechnical Standards and Codes Committee E0005. As
the regulations of wire size and circuit breaker differ in each country or region, select appropriate de-
vices complied to the regional standard.
3
*
: Maximum Circuit Breaker
4
*
: Limit voltage drop to less than 2%. If voltage drop is 2% or more, increase cable conductor size.
3
Size
Limited wiring
4
length
AOUH18LMAS1
V
Hz
A
17.1
A
7.0
A
AWG
14
AWG
ft (m)
- 81 -
AOUH24LMAS1
208/230
60
19.6
8.3
20
12
14
167 (51)