Siemens SIMATIC NET RUGGEDCOM RX1511 Installation Manual

Siemens SIMATIC NET RUGGEDCOM RX1511 Installation Manual

Rugged multi service platforms
Hide thumbs Also See for SIMATIC NET RUGGEDCOM RX1511:

Quick Links

Installation Manual
SIMATIC NET
Rugged Multi Service Platforms
RUGGEDCOM RX1511
Edition
01/2021
https://www.siemens.com
Table of Contents
loading

Summary of Contents for Siemens SIMATIC NET RUGGEDCOM RX1511

  • Page 1 Installation Manual SIMATIC NET Rugged Multi Service Platforms RUGGEDCOM RX1511 Edition 01/2021 https://www.siemens.com...
  • Page 2 Preface Introduction Installing the Device SIMATIC NET Device Management Rugged Multi Service Platforms RUGGEDCOM RX1511 Modules Technical Specifications Installation Manual Certification 01/2021 C79000-G8976-1056-19...
  • Page 3 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 4: Table Of Contents

    Accessing Documentation ....................... v Registered Trademarks ......................v Warranty ..........................vi Training ..........................vi Customer Support ........................vi Contacting Siemens ....................... vii Introduction ........................... 1 Feature Highlights ....................1 Description ......................1 Required Tools and Materials ................. 3 Decommissioning and Disposal ................3 Cabling Recommendations ..................
  • Page 5 Table of Contents Technical Specifications ...................... 45 Power Supply Specifications ................45 Failsafe Relay Specifications ................45 Operating Environment ..................46 Mechanical Specifications ..................46 Dimension Drawings ................... 46 Certification ......................... 49 Approvals ......................49 6.1.1 TÜV SÜD ......................49 6.1.2 European Union (EU) ..................
  • Page 6: Preface

    Siemens Customer Support. Registered Trademarks RUGGEDCOM®, ROS®, RCDP®, and RUGGEDCOM Discovery Protocol® are registered trademarks of Siemens Canada Ltd. Linux® is the registered trademark of Linus Torvalds in the United States and other countries. The registered trademark Linux® is used pursuant to a sublicense from LMI, the exclusive licensee of Linus Torvalds, owner of the mark on a world-wide basis.
  • Page 7: Warranty

    Preface Warranty Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
  • Page 8: Contacting Siemens

    Call a local hotline center to submit a Support Request (SR). To locate a local hotline center, visit https://w3.siemens.com/aspa_app/?lang=en. Mobile App Install the Industry Online Support app by Siemens AG on any Android, Apple iOS or Windows mobile device and be able to: •...
  • Page 9 Preface Contacting Siemens viii RUGGEDCOM RX1511 Installation Manual, 01/2021, C79000-G8976-1056-19...
  • Page 10: Introduction

    Introduction The RUGGEDCOM RX1511 is a cost-efficient, rugged Layer 3 switch and router. The RUGGEDCOM RX1511’s modular and field replaceable platform can be equipped with WAN, serial, and Ethernet options, making it ideally suited for electric power utilities, the industrial plant floor, and traffic control systems. The appliance’s compact form factor makes it ideal for pole mount applications or installation in restricted spaces.
  • Page 11 Introduction 1.2 Description Utility USB Port RS232 Serial Console Port (RJ45) Lamp Test/Alarm Cut-Off (LT/ACO) Button Compact Flash Card Port Alarm Indicator LED Port Status LEDs Management Port Figure 1.1 RUGGEDCOM RX1511 Management Port This 10/100Base-T Ethernet port is used for system management that is out-of-band from the switch fabric.
  • Page 12: Required Tools And Materials

    Introduction 1.3 Required Tools and Materials • Red = Alarm Compact Flash Card Port Houses the CompactFlash (CF) card that contains active and backup installations of RUGGEDCOM RUGGEDCOM RX1511, along with the configuration database and other system data. For more information, refer to "Accessing the CompactFlash Card (Page 21)".
  • Page 13: Cabling Recommendations

    Siemens also does not recommend using copper Ethernet ports to interface with devices in the field across distances that could produce high levels of ground potential rise (i.e. greater than 2500 V), during line-to-ground fault conditions.
  • Page 14: Installing The Device

    This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens AG could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
  • Page 15: General Procedure

    Inspect the package for damage before opening it. Visually inspect each item in the package for any physical damage. Verify all items are included. IMPORTANT If any item is missing or damaged, contact Siemens for assistance. RUGGEDCOM RX1511 Installation Manual, 01/2021, C79000-G8976-1056-19...
  • Page 16: Mounting The Device

    Installing the Device 2.3 Mounting the Device Mounting the Device The RUGGEDCOM RX1511 is designed for maximum mounting and display flexibility. It can be equipped with connectors that allow it to be installed in a 35 mm (1.4 in) DIN rail, or directly on a panel. IMPORTANT Heat generated by the device is channeled outwards from the enclosure.
  • Page 17: 2.3.2 Mounting The Device To A Panel

    Installing the Device 2.3.2 Mounting the Device to a Panel 2.3.2 Mounting the Device to a Panel For panel installations, the RUGGEDCOM RX1511 can be equipped with panel/DIN rail adapters pre-installed on each side of the chassis. The adapters allow the device to be attached to a panel using screws.
  • Page 18: Connecting Power

    Installing the Device 2.5 Connecting Power For more information, refer to the RUGGEDCOM ROX Configuration Manual for the RUGGEDCOM RX1511. The following shows the proper relay connections. Normally Open Common Normally Closed Figure 2.3 Failsafe Alarm Relay Wiring Connecting Power The RUGGEDCOM RX1511 supports a single high AC, high DC or low DC power module.
  • Page 19: 2.5.1 Connecting High Ac/Dc Power

    Installing the Device 2.5.1 Connecting High AC/DC Power • Equipment must be installed according to applicable local wiring codes and standards. 2.5.1 Connecting High AC/DC Power To connect a high AC/DC power supply to the device, do the following: DANGER Electrocution hazard – risk of death, serious personal injury and/or damage to the device Make sure the supplied cover is always installed over high voltage screw terminal blocks.
  • Page 20 Installing the Device 2.5.1 Connecting High AC/DC Power Connect the power supply terminal block to the device. European-style (Euroblock) Terminal Block Positive/Live (+/L) Terminal Ground Terminal Negative/Neutral (-/N) Terminal Figure 2.4 AC Terminal Block Wiring – European-style (Euroblock) Terminal Block for HIP Power Supplies Not Connected Removable Screw Terminal Block...
  • Page 21 Installing the Device 2.5.1 Connecting High AC/DC Power IMPORTANT For secure, reliable connections under severe shock or vibration, use M3.5 ring lugs with a maximum outer diameter of 7 mm (0.28 in). Make sure no bare metal is exposed beyond the safety cover. Connect the positive wire from the power source to the positive/live (+/L) terminal on the terminal block.
  • Page 22: 2.5.2 Connecting Low Dc Power

    Installing the Device 2.5.2 Connecting Low DC Power Using a #10 ring lug and #10-32 screw, secure the ground terminal on the power source to the ground connection on the device. Make sure the lug is tightened to 1.1 N·m (9.5 lbf·in). #10 Ring Lug #10-32 Screw Connection from External Power Source...
  • Page 23 Installing the Device 2.5.2 Connecting Low DC Power Connect the power supply terminal block to the device. European-style (Euroblock) Terminal Block Positive (+) Terminal Negative (-) Terminal Ground Terminal Figure 2.8 DC Terminal Block Wiring – European-style (Euroblock) Terminal Block for 12P, 24P and 48P Power Supplies Not Connected Removable Screw Terminal Block...
  • Page 24 Installing the Device 2.5.2 Connecting Low DC Power Ground Terminal Figure 2.9 DC Terminal Block Wiring – Screw Terminal Block for 12P, 24P and 48P Power Supplies European-style (Euroblock) Terminal Block Positive (+) Terminal Negative (-) Terminal Ground Terminal Figure 2.10 DC Terminal Block Wiring – European-style (Euroblock) Terminal Block for -12P, -24P and -48P Power Supplies Not Connected Removable Screw Terminal Block...
  • Page 25 Installing the Device 2.5.2 Connecting Low DC Power Negative (-) Terminal Ground Terminal Figure 2.11 DC Terminal Block Wiring – Screw Terminal Block for -12P, -24P and -48P Power Supplies IMPORTANT For secure, reliable connections under severe shock or vibration, use M3.5 ring lugs with a maximum outer diameter of 7 mm (0.28 in).
  • Page 26 Installing the Device 2.5.2 Connecting Low DC Power Using a #10 ring lug and #10-32 screw, secure the ground terminal on the power source to the ground connection on the device. Make sure the lug is tightened to 2.4 N·m (9.5 lbf·in). #10 Ring Lug #10-32 Screw Connection from External Power Source...
  • Page 27 Installing the Device 2.5.2 Connecting Low DC Power RUGGEDCOM RX1511 Installation Manual, 01/2021, C79000-G8976-1056-19...
  • Page 28: Device Management

    It may cause damage to the contact pins of the RJ45 ports. For a permanent solution, use Siemens 6XV1870-3Qxxx certified cables (manufactured December 2019 or after) or equivalent. Siemens recommends using Siemens certified cables and connectors for Siemens RUGGEDCOM products.
  • Page 29 Device Management 3.1 Connecting to the Device Serial Console and Management Ports Connect a workstation directly to the serial console or management ports to access the boot-time control and RUGGEDCOM RX1511 interfaces. The serial console port provides access to RUGGEDCOM RX1511 's console interface, while the management port provides access to RUGGEDCOM RX1511's console and Web interfaces.
  • Page 30: Configuring The Device

    The following will void the warranty and potentially result in configuration data corruption/loss: • Using a CF card not approved by Siemens for use with this device • Removing the CF card in any scenario other than those described in this section...
  • Page 31 Device Management 3.3 Accessing the CompactFlash Card Inserting the CF card To insert the CF card into the device, do the following: IMPORTANT The device should only be powered on when the CF card is present. Make sure the device is powered down. Remove the CF card access panel.
  • Page 32 Device Management 3.3 Accessing the CompactFlash Card Remove the CF card access panel. Ejector Button CompactFlash Card Access Panel Figure 3.4 Removing the CF Card Press the ejector button to the left of the CF card and then pull the card out. Secure the CF card access panel to the chassis.
  • Page 33 Device Management 3.3 Accessing the CompactFlash Card RUGGEDCOM RX1511 Installation Manual, 01/2021, C79000-G8976-1056-19...
  • Page 34: Modules

    Modules The RUGGEDCOM RX1511 features slots for up to two field-replaceable line modules, which can be used to expand and customize the capabilities of the device to suit specific applications. A variety of modules are available, each featuring a specific type of communication port: copper Ethernet, fiber optic Ethernet, SFP, WAN, cellular modem and DDS.
  • Page 35: Available Modules

    Available Modules The following is a list of all power and line modules available for use in the RUGGEDCOM RX1511. For more information about individual modules, refer to the RUGGEDCOM RX1500 Series Modules Catalog [https://support.industry.siemens.com/ cs/ca/en/view/109747072]. Power Supply Modules RUGGEDCOM RX1500PN PS 12 (shipped until...
  • Page 36 Modules 4.2 Available Modules RUGGEDCOM RX1500PN PS 24P Specifications Article Numbers Input Range: 13 to 36 6GK6015-0AL14-0AA0 (Standard) Terminal Type: 6GK6015-0AL14-0AA1 European-style (Conformal Coated) (Euroblock) RUGGEDCOM RX1500PN PS 48 (shipped until Specifications Article Numbers 2019) Input Range: 36 to 72 6GK6015-0AL12-0AA0 (Standard) Terminal Type: Non- 6GK6015-0AL12-0AA1...
  • Page 37 Modules 4.2 Available Modules Input Range: 88 to 300 6GK6015-0AL13-0AA0 VDC or 85 to 264 VAC (Standard) Terminal Type: 6GK6015-0AL13-0AA1 Removable Screw (Conformal Coated) RUGGEDCOM RX1500PN PS HIP Specifications Article Numbers Input Range: 88 to 300 6GK6015-0AL16-0AA0 VDC or 85 to 264 VAC (Standard) Terminal Type: 6GK6015-0AL16-0AA1...
  • Page 38 Modules 4.2 Available Modules Speed: 1000 Mbps 6GK6015-0AL20-0PH1 (Conformal Coated) Interface: TX Port Type: M12 (8-pin, X-Coded) Distance: 100 m (328 ft) Power Consumption: 4 RUGGEDCOM RX1500PN LM X CG04B Specifications Article Numbers Ports: 2 6GK6015-0AL20-0PJ0 (Standard) Speed: 1000 Mbps 6GK6015-0AL20-0PJ1 Interface: TX (Conformal Coated) Port Type: M12 (8-pin,...
  • Page 39 Modules 4.2 Available Modules Ports: 4 6GK6015-0AL20-0PG0 (Standard) Speed: 100 Mbps 6GK6015-0AL20-0PG1 Interface: TX (Conformal Coated) Port Type: M12 (4-Pin, A-Coded, Controlled Bypass) Distance: 100 m (328 ft) Power Consumption: 5 RUGGEDCOM RX1500PN LM 6TX01 Specifications Article Numbers Ports: 6 6GK6015-0AL20-0NB0 (Standard) Speed: 100 Mbps 6GK6015-0AL20-0NB1...
  • Page 40 Modules 4.2 Available Modules Ports: 4 Port Type: LC Distance: 10 km (6.2 Power Consumption: 5 RUGGEDCOM RX1500PN LM FG50 Specifications Article Numbers SFP Sockets: 2 6GK6015-0AL20-0JB0 (Standard) Speed: 1000 Mbps 6GK6015-0AL20-0JB1 Power Consumption: 7 (Conformal Coated) RUGGEDCOM RX1500PN LM FG51 Specifications Article Numbers Mode: MM...
  • Page 41 Modules 4.2 Available Modules Interface: FX 6GK6015-0AL20-0BK1 (Conformal Coated) Wavelength: 1310 nm Ports: 6 Port Type: LC Distance: 2 km (1.2 mi) Power Consumption: 7 WAN Modules RUGGEDCOM RX1500PN LM S01 Specifications Article Numbers Standard: RS232/RS422/ 6GK6015-0AL20-0KB0 RS485 (Standard) Ports: 6 6GK6015-0AL20-0KB1 (Conformal Coated) Port Type: RJ45...
  • Page 42 Modules 4.2 Available Modules Ports: 1 6GK6015-0AL20-0LB1 (Conformal Coated) Port Type: RJ48S Power Consumption: 3 Cellular Modem Modules RUGGEDCOM RX1500PN LM W11 Specifications Article Numbers Services: GSM/EDGE/ 6GK6015-0AL20-0WB0 HSPA+ (Standard) Region: North America 6GK6015-0AL20-0WB1 (AT&T) (Conformal Coated) Port Type: 50 Ω SMA Antennas: 1 x GSM/ EDGE/HSPA+, 1 x Receive Diversity...
  • Page 43 Modules 4.2 Available Modules Services: EVDO Rev A 6GK6015-0AL20-0WE0 (Standard) Region: North America (Verizon) 6GK6015-0AL20-0WE1 (Conformal Coated) Port Type: 50 Ω SMA Antennas: 2 x EVDO Rev A, 2 x Receive Diversity (Secondary) SIM: Dual Mini-SIM (2FF) Power Consumption: 7 RUGGEDCOM RX1500PN LM W32 Specifications Article Numbers Services: EVDO Rev A...
  • Page 44 Modules 4.2 Available Modules SIM: Dual Mini-SIM (2FF) Power Consumption: 7 RUGGEDCOM RX1500PN LM W61 Specifications Article Numbers Services: 4G LTE/HSPA+/ 6GK6015-0AL20-0WJ0 CDMA/EVDO/GPS/GNSS (Standard) Region: North America 6GK6015-0AL20-0WJ1 (Verizon, Sprint) (Conformal Coated) Port Type: 50 Ω SMA Antennas: 1 x LTE Main, 1 x LTE MIMO, 1 x GPS SIM: Dual Mini-SIM (2FF)
  • Page 45 Modules 4.2 Available Modules Power Consumption: 10 RUGGEDCOM RX1500PN LM APE1402W7 Specifications Article Numbers (Obsolete) Operating System: 6GK6015-0AL20-0GC0 Windows® Embedded (Standard) Standard 7 6GK6015-0AL20-0GC1 Processor: Intel Atom (Conformal Coated) E660 1.3 GHz, 512 KB L2 Cache RAM: 2 GB DDR2, 800 MHz, 32-bit Disk: 8 GB SATA, Solid State...
  • Page 46 Modules 4.2 Available Modules Disk: 16 GB SATA, Solid State Networking: Realtek RTL8111, RJ45 Gigabit Ethernet Interface USB: 2 x USB 2.0 Video: Intel 4108 Graphics Processor, DVI- Power Consumption: 10 RUGGEDCOM RX1500PN LM APE1404W7 Specifications Article Numbers (Obsolete) Operating System: 6GK6015-0AL20-0GE0 Windows®...
  • Page 47 Modules 4.2 Available Modules Operating System: 6GK6015-0AL20-0GH0 Debian Linux® (Standard) Processor: Intel x5- 6GK6015-0AL20-0GH1 E3940 1.8 GHz, 2 MB L2 (Conformal Coated) Cache RAM: 8 GB DDR3 ECC, 1600 MHz, 64-bit Disk: 64 GB, Solid State Networking: Intel I210, RJ45 Gigabit Ethernet Interface USB: 2 x USB 3.0 Video: Intel HD Graphics...
  • Page 48: Installing/Removing Line Modules

    Modules 4.3 Installing/Removing Line Modules Power Consumption: 12 RUGGEDCOM RX1511PN LM APE1808CKP Specifications Article Numbers Operating System: 6GK6015-0AL20-0GK0 Check Point GAiA™ OS (Standard) Processor: Intel x5- 6GK6015-0AL20-0GK1 E3940 1.8 GHz, 2 MB L2 (Conformal Coated) Cache RAM: 8 GB DDR3 ECC, 1600 MHz, 64-bit Disk: 64 GB, Solid State Networking: Intel I210,...
  • Page 49 Modules 4.3 Installing/Removing Line Modules NOTICE Electrical hazard – risk of power failure When installing more than one line module in the device, make sure the total power consumption of all line modules does not exceed 41.5 W (i.e. the total power made available to the modules by the chassis).
  • Page 50 Modules 4.3 Installing/Removing Line Modules Pull the module from the chassis to disconnect it. Module Chassis Screw Figure 4.2 Removing a Module Install a new module or a blank module (to prevent the ingress of dust and dirt). [Optional] If necessary, install the device in the rack. Installing a Module To install a line module, do the following: [Optional] If the device is installed in a rack, remove it from the rack.
  • Page 51: Installing/Removing Power Modules

    Modules 4.4 Installing/Removing Power Modules Insert the new module into the slot. Module Chassis Screw Figure 4.3 Installing a Module Tighten the screws to secure the module. [Optional] If necessary, install the device in the rack. Installing/Removing Power Modules The RUGGEDCOM RX1511 supports a single power module. Power Module Figure 4.4 Power Module...
  • Page 52 Modules 4.4 Installing/Removing Power Modules NOTICE Contamination hazard – risk of equipment damage Prevent the ingress of water, dirts and other debris that may lead to premature equipment failure. Always make sure slots are not left empty. Removing a Power Module To remove a power module, do the following: DANGER Electrocution hazard –...
  • Page 53 Modules 4.4 Installing/Removing Power Modules Installing a Power Module To install a power module, do the following: If equipped, remove the existing module. If applicable, connect the supplied terminal block to the module or connect the terminal block from the previous module. Confirm or connect the wiring from the power supply to the module.
  • Page 54: Technical Specifications

    Technical Specifications This section provides important technical specifications related to the device. Power Supply Specifications Note When determining cable lengths, make sure the minimum input voltage for the power supply is provided at the power source. Input Range Maximum Power Internal Power Insulation...
  • Page 55: Operating Environment

    Technical Specifications 5.3 Operating Environment Operating Environment The RUGGEDCOM RX1511 is rated to operate under the following environmental conditions. IMPORTANT Temperature limits for select line modules may differ from that which can be withstood by the RUGGEDCOM RX1511. Make sure the selected modules are rated for the expected environmental conditions before deployment.
  • Page 56 Technical Specifications 5.5 Dimension Drawings 151.1 Figure 5.1 Overall Dimensions RUGGEDCOM RX1511 Installation Manual, 01/2021, C79000-G8976-1056-19...
  • Page 57 Technical Specifications 5.5 Dimension Drawings 199.9 152.4 189.9 78.2 Figure 5.2 Panel and Din Rail Mount Dimensions 162.5 151.4 19.7 Figure 5.3 Line Module Dimensions 162.5 151.8 40.6 Figure 5.4 Power Module Dimensions RUGGEDCOM RX1511 Installation Manual, 01/2021, C79000-G8976-1056-19...
  • Page 58: Certification

    UL 62368-1 Information Technology Equipment – Safety – Part 1: General Requirements 6.1.2 European Union (EU) This device is declared by Siemens AG to comply with essential requirements and other relevant provisions of the following EU directives: • Directive 2014/30/EU...
  • Page 59: 6.1.3 Fcc

    The device is marked with a CE marking and notified body number, and can be used throughout the European community. 0680 A copy of the CE Declaration of Conformity is available from Siemens AG. For contact information, refer to "Contacting Siemens (Page vii)".
  • Page 60: Fda/Cdrh

    Title 21 Code of Federal Regulations (CFR) – Chapter I – Sub-chapter J – Radiological Health 6.1.5 ISED This device is declared by Siemens AG to meet the requirements of the following ISED (Innovation Science and Economic Development Canada) standard: • CAN ICES-3 (A)/NMB-3 (A) 6.1.6...
  • Page 61: 6.1.8 Other Approvals

    Certification 6.1.8 Other Approvals A copy of the Material Declaration is available online at https:// support.industry.siemens.com/cs/ww/en/view/109738831. 6.1.8 Other Approvals This device meets the requirements of the following additional standards: IEEE 1613 • IEEE Standard Environmental and Testing Requirements for Communications Networking Devices in Electric Power Substations •...
  • Page 62 5 kV (Failsafe Relay output) DC Power Ports 5 kV AC Power Ports Siemens-specified severity levels. EMC Immunity Type Tests for IEEE 1613 Note The RUGGEDCOM RX1511 meets Class 2 requirements for an all-fiber configuration and Class 1 requirements for copper ports. Class 1 allows for temporary communication loss, while Class 2 requires error-free and interrupted communications.
  • Page 63 Certification 6.2 EMC and Environmental Type Tests Description Test Levels Earth ground ports Oscillatory Signal ports 2.5 kV common mode @1MHz DC Power Ports 2.5 kV common AC Power Ports 1 kV differential mode @ 1 MHz Radiated RFI Enclosure ports 35 V/m Enclosure Contact ±...
  • Page 64 Further Information Siemens RUGGEDCOM https://www.siemens.com/ruggedcom Industry Online Support (service and support) https://support.industry.siemens.com Industry Mall https://mall.industry.siemens.com Siemens AG Digital Industry Process Automation Postfach 48 48 90026 NÜRNBERG GERMANY...

Table of Contents