Siemens SIMATIC IPC277D/E 19" INOX PRO Service Manual

Industrial pc, industrial monitor

Quick Links

SIMATIC
Industrial PC, Industrial monitor
SIMATIC IPC277D/E 19" INOX PRO,
SIMATIC IFP1900 INOX PRO
Service Manual
11/2017
A5E35751762-AC
___________________
Preface
___________________
Overview
___________________
Safety instructions
___________________
Replacing the seal of the
compartment cover
___________________
Extended maintenance work
___________________
Accessories and spare parts
___________________
Technical support
1
2
3
4
5
A
Table of Contents
loading

Summary of Contents for Siemens SIMATIC IPC277D/E 19" INOX PRO

  • Page 1 ___________________ Preface ___________________ Overview ___________________ SIMATIC Safety instructions ___________________ Replacing the seal of the compartment cover Industrial PC, Industrial monitor SIMATIC IPC277D/E 19" INOX PRO, ___________________ SIMATIC IFP1900 INOX PRO Extended maintenance work ___________________ Accessories and spare parts Service Manual ___________________ Technical support 11/2017...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Preface

    Preface Validity This document applies to devices with the designation IPC277D/E 19" INOX PRO and IFP1900 INOX PRO with the following article numbers: Article number Device 6AV7484-4AB00-0AA0 IPC277D 19" INOX PRO, stand mounting (with operator controls) 6AV7484-4AB10-0AA0 IPC277D 19" INOX PRO, support arm mounting (with operator controls) 6AV7484-5AB00-0AA0 IPC277E 19"...
  • Page 4: Table Of Contents

    Table of contents Preface ............................3 Overview ............................. 5 Safety instructions ......................... 6 Replacing the seal of the compartment cover ................... 7 Extended maintenance work ......................9 Overview ..........................10 Opening the device and loosening cables ................12 Replacing the seal of the rear panel ...................14 Replacing operator controls ....................16 Changing the mounting type ....................19 Fastening the rear panel .....................21...
  • Page 5: Overview

    Overview The INOX PRO devices are available with or without operator controls on the front and are intended for "stand mounting" or "support arm mounting". The figure below shows the front view using a device with operator controls as an example. ①...
  • Page 6: Safety Instructions

    Injuries or material damage may result if the work is not carried out correctly. The maintenance work described in the Service Manual may only be carried out by qualified specialist personnel who have been trained correspondingly by Siemens. WARNING IP66 degree of protection The device has IP66 degree of protection when it is closed.
  • Page 7: Replacing The Seal Of The Compartment Cover

    Replacing the seal of the compartment cover WARNING IP66 degree of protection The device has IP66 degree of protection when it is closed. If the terminal compartment seal is not inserted correctly or if the terminal compartment is not closed properly, IP66 degree of protection is no longer guaranteed.
  • Page 8 Replacing the seal of the compartment cover 1. Remove the six screws of the terminal compartment cover. 2. Remove the terminal compartment cover. CAUTION Do not drop the terminal compartment cover Dropping the terminal compartment cover may result in minor injuries or damages to the device.
  • Page 9: Extended Maintenance Work

    The work described in the service manual may only be carried out by qualified specialist personnel who have been trained correspondingly by Siemens. WARNING After opening the device, you must replace the seal of the rear panel The device has IP66 degree of protection when it is closed.
  • Page 10: Overview

    Extended maintenance work 4.1 Overview Components sensitive to electrostatic charge Electrostatic sensitive devices are labeled with an appropriate symbol. NOTICE Electrostatic sensitive devices (ESD) The device includes electrostatic sensitive devices. When you touch electrostatic sensitive devices, you can destroy them through voltages that are far below the human perception threshold.
  • Page 11 Extended maintenance work 4.1 Overview Flowchart Perform the maintenance work according to the following flowchart: SIMATIC IPC277D/E 19" INOX PRO, SIMATIC IFP1900 INOX PRO Service Manual, 11/2017, A5E35751762-AC...
  • Page 12: Opening The Device And Loosening Cables

    Extended maintenance work 4.2 Opening the device and loosening cables Opening the device and loosening cables Requirement ● The device has been removed from the stand or support arm. ● The connection cables have been removed from the device interfaces. ●...
  • Page 13 Extended maintenance work 4.2 Opening the device and loosening cables 4. Loosen the plug of the LVDS display cable from the front electronic. To do so, press the two locking mechanisms (A) on the side of the plug and pull out the plug as shown in the figure below.
  • Page 14: Replacing The Seal Of The Rear Panel

    Extended maintenance work 4.3 Replacing the seal of the rear panel 7. Only for devices with operator controls: Pull out the plug of the flat ribbon cable from the rear panel electronic as shown in the figure below. 8. Place all cables whose plugs you have removed on the rear panel and the front as shown in the figure below.
  • Page 15 Extended maintenance work 4.3 Replacing the seal of the rear panel Procedure 1. Remove the seal from the front. 2. Insert the spare seal in the device front as shown in the figure. Make sure that the positioning tabs of the seal are fully inserted into the corresponding bore holes of the front.
  • Page 16: Replacing Operator Controls

    Extended maintenance work 4.4 Replacing operator controls Replacing operator controls This section applies to devices with operator controls. Note Repairs, when modules are defective The modules of the EMERGENCY OFF pushbutton and the illuminated pushbutton are not available as spare part. If one of the modules is defective, send in the device for repair.
  • Page 17 Extended maintenance work 4.4 Replacing operator controls Replacing the illuminated pushbutton Removing the illuminated pushbutton 1. Carefully turn the module of the illuminated pushbutton you want to remove to the right until it is upright. 2. Remove the module from the illuminated pushbutton.
  • Page 18 Extended maintenance work 4.4 Replacing operator controls Installing the illuminated pushbutton Proceed in the reverse order of the section "Removing the illuminated pushbutton". 1. Insert the new illuminated pushbutton from the outside through the opening on the front. 2. Fasten the illuminated pushbutton with the associated nut, 1.5 Nm torque. 3.
  • Page 19: Changing The Mounting Type

    Extended maintenance work 4.5 Changing the mounting type Changing the mounting type This section describes the conversion of a stand-mounted device into a support arm device. The conversion of a support arm device into a stand-mounted device takes place in the same manner.
  • Page 20 Extended maintenance work 4.5 Changing the mounting type 5. Reposition the LVDS display cable, the touch cable and the BLI cable from the rear panel to the front as shown in the figure below. 6. Only for devices with operator controls: Connect the plug of the flat ribbon cable with the rear panel electronic.
  • Page 21: Fastening The Rear Panel

    Extended maintenance work 4.6 Fastening the rear panel 8. Place the rear panel on the front, and carefully lower the rear panel as shown in the figures below. Make sure that you do not pinch the cables, especially the flat ribbon cable that is highlighted in the figure.
  • Page 22 Extended maintenance work 4.6 Fastening the rear panel Tool required Allen wrench, size 8 mm Procedure 1. Make sure that the seal is flush with the rear panel and does not protrude between rear panel and front. 2. Screw in the four screws in the corners of the rear panel about halfway as shown in the figure below.
  • Page 23: Accessories And Spare Parts

    Accessories and spare parts Accessories Mounting kit for stand mounting A mounting kit is available for stand mounting of the device. Mounting kit contents: ● 1 stainless steel tube with flange: Length 500 mm, outer diameter 48.3 mm, inner diameter 40 mm. The mechanical interface of the stainless steel tube with flange fits the mechanical interface of the device.
  • Page 24 Accessories and spare parts Service pack 2, use only in combination with this service manual The service pack 2 contains: ● 1 spare seal for the rear panel of the device ● 4 spare screws for the rear panel of the device ●...
  • Page 25: Technical Support

    You can find additional information and support for the products described on the Internet at the following addresses: ● Technical support (http://www.siemens.de/automation/csi_en_WW) ● Support request form (http://www.siemens.com/automation/support-request) ● After Sales Information System SIMATIC IPC/PG (http://www.siemens.com/asis) ● SIMATIC Documentation Collection (http://www.siemens.com/simatic-tech-doku-portal) ● Your local representative (http://www.automation.siemens.com/mcms/aspa-db/en/Pages/default.aspx) ●...