Quick Links

SAT-IDP
SAT-IDP Series
User Guide
Dated: 18th December 2020
Honeywell Global Tracking Ltd
Document Number: MAN-0077
Issue No. 6
Table of Contents
loading

Summary of Contents for Honeywell SAT-IDP Series

  • Page 1 SAT-IDP SAT-IDP Series User Guide Document Number: MAN-0077 Issue No. 6 Dated: 18th December 2020 Honeywell Global Tracking Ltd...
  • Page 2 Disclaimer Honeywell International Inc. (“HII”) reserves the right to make changes in specifications and other information contained in this document without prior notice, and the reader should in all cases consult HII to determine whether any such changes have been made. The information in this publication does not represent a commitment on the part of HII.
  • Page 3: Table Of Contents

    Table of Contents SAT-IDP ................1 SAT-IDP Series .............. 1 User Guide ..............1 Table of Contents ............1 Preface ................2 General Safety Warnings ............2 Chapter 1 – Regulatory and Type Approval ....3 1.1 Inmarsat Type Approval ..........3 1.2 European Compliance ...........
  • Page 4: Preface

    20 centimetres is normally maintained between the transmitter’s radiating structures and the body of the user or nearby persons.) MAN-0077 Honeywell Global Tracking Ltd...
  • Page 5: Chapter 1 - Regulatory And Type Approval

    The following information is provided on the device covered in this document in compliance with FCC regulations:  Model number: SAT-IDP (all variants)  Company Name: EMS Technologies Canada Ltd. Honeywell Global Tracking CA 400 Maple Grove Rd Ottawa ON K2V 188 CANADA The product complies with FCC requirements: MAN-0077 Honeywell Global Tracking Ltd...
  • Page 6: Fcc Cfr:15.21 Information To User

    .L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. MAN-0077 Honeywell Global Tracking Ltd...
  • Page 7: Limitations On Intended Operating Environment

    Guidance notes for the installation and use of the SAT-IDP must be strictly followed. Honeywell Global Tracking exercises due diligence to ensure that the equipment is suitable for use in stated applications, but ultimate responsibility for the compliance of a complete system must rest with the prime contractor at a site where local conditions may require additional EMC precautions be taken.
  • Page 8: Chapter 2 - General Description

    Chapter 2 – General Description This document refers to the SAT-IDP series, including their variants. Variants are indicated by alphabetic suffixes. Most variants differ in physical characteristics only – for example bottom or side entry connector, magnetic feet etc. The SAT-IDP is a compact, single unit, low data rate satellite terminal, designed to operate over the Inmarsat satellites using the IsatData Pro protocols.
  • Page 9 WARNING: The SAT-IDP-SC magnetic feet are not designed for fitting to vehicles driven at speed or over rough terrain. It is the user’s responsibility to ensure that the equipment is secure when fitted to a vehicle and that the vehicle is driven safely. MAN-0077 Honeywell Global Tracking Ltd...
  • Page 10: Chapter 3 - Installation

    SELV limits of EN 60950-1. 3.2 Cable It is recommended that cable routing is planned and operation tested before committing to a permanent installation. The maximum cable diameter must not exceed 7mm, the maximum allowed by the terminal connector. MAN-0077 Honeywell Global Tracking Ltd...
  • Page 11: Location

    Choose a location that is not near radar installations, other satellite communication equipment, and/or microwave dishes to prevent RF jamming.  Avoid mounting on hot surfaces.  Avoid prolonged exposure to anti-freeze, detergents, windscreen washer fluid and any other similar chemicals. MAN-0077 Honeywell Global Tracking Ltd...
  • Page 12: Mounting

    Secure using M25 nut - Do not over tighten (2.0Nm Max).  Do not paint the SAT-IDP enclosure.  Do not attach any foreign object to the enclosure anywhere above the three outer mounting holes. MAN-0077 Honeywell Global Tracking Ltd...
  • Page 13 Figure 4 - SAT-IDP M4 Drilling Diagram (not to scale) Figure 5 - SAT-IDP M25 Drilling Template (not to scale) MAN-0077 Honeywell Global Tracking Ltd...
  • Page 14 Figure 6 - SAT-401C M25 Drilling Template (not to scale) Figure 7 - SAT-IDP Foam Washer Dimensions (not to scale) MAN-0077 Honeywell Global Tracking Ltd...
  • Page 15: Applying Power

    If you do not have access to an application of your own, it is possible to set up your terminal on one of the Honeywell Global Tracking websites in order to perform end-to-end testing. Please consult your service provider for details of the activation that has been put in place for your terminal. If you do not have access to the application, it is still possible to check the local operation of the terminal and its installation by using the following sequence.
  • Page 16 Honeywell Global Tracking server. Your service provider will be able to supply you with further details regarding the normal use of the terminal, as well as scripts and forward channel use.
  • Page 17: Chapter 4 - Functionality

    Chapter 4 - Functionality For full functional details of the SAT-IDP contact your authorised dealer. MAN-0077 Honeywell Global Tracking Ltd...
  • Page 18: Chapter 5 - Factory Defaults

    GPS position and tunes to the best ocean region for the terminal location. Once the terminal has acquired the IDP satellite signal it transmits a single position report burst. MAN-0077 Honeywell Global Tracking Ltd...
  • Page 19: Chapter 6 - Maintenance And Support

    Dust and finger marks can be removed using a soft damp cloth. Avoid using domestic cleaning products. 6.2 Technical Support and Information For technical support, product queries and information please contact your equipment supplier or authorised dealer. Alternatively, contact Honeywell Global Tracking directly for details of your dealer: EMS Technologies Canada Ltd. Honeywell Global Tracking CA...
  • Page 20: Chapter 7 - Interfaces

    SA3179 (pack of 10). Contact Bulgin for crimp tool details 4. Insertion/extraction tool: 13027 Items 1, 2 and 4 can be purchased as a kit from your equipment supplier or authorised dealer (Honeywell Global Tracking product number: A021B01). 7.1 SAT-IDP Interface Pinout...
  • Page 21: General Purpose I/O

     Low voltage digital output (3.3V) Note on USB to RS-232 Converters Honeywell Global Tracking recommends the FTDI chipset USB to serial converters for use with the SAT-IDP terminal and the terminal programming utility software. 7.3 General Purpose I/O Figure 8 shows a conceptual drawing of one of the general purpose I/O’s.
  • Page 22 Figure 9 shows a conceptual drawing of the open drain output (OD_OUT). OD_OUT Open drain 0V (Vin-) Figure 9 – SAT-IDP output block diagram MAN-0077 Honeywell Global Tracking Ltd...
  • Page 23: Chapter 8 - Interpreting The Indicator

    Note: The indicator can be disabled (off state) or enabled via script control. The indicator may therefore not come on when power is applied. Contact your authorised dealer for details of any script that may have been programmed into the SAT-IDP. MAN-0077 Honeywell Global Tracking Ltd...
  • Page 24: Chapter 9 - Security Guide

    Chapter 9 – Security Guide Figure 10 – Typical SAT IDP Installation System Architecture MAN-0077 Honeywell Global Tracking Ltd...
  • Page 25: Security Checklists

    Use a firewall at the interface between other  networks and Honeywell components. 9.1.2 Unauthorized External Access This threat includes intrusion into your Honeywell system from the business network or other external networks including the Internet. Unauthorized external access can result in: ...
  • Page 26: Unauthorized Internal Access

    9.1.3 Unauthorized Internal Access This threat encompasses unauthorized access from people or systems with direct access to a Honeywell system component. This threat is the most difficult to counter since attackers may have legitimate access to part of the system and are simply trying to exceed their permitted access.
  • Page 27: Accidental System Change

    Mitigation steps Do not allow the use of unauthorized  removable media (e.g., microSD™ or microSDHC™ cards) on Honeywell solution components.  Implement strong password protection on Honeywell solution components and include a password lifetime management policy, reuse policy, and strength policy for passwords.
  • Page 28: Securing The Infrastructure

    9.2 Securing the Infrastructure Although the security issues for the Honeywell system are generally the same as any IT solution, the physical security of the network and environment is particularly important. If the hardware is rendered inoperable, the operation of Honeywell solution and the entire facility can be compromised.
  • Page 29: Appendix A - Specifications

    Up to 84 bits Message length (double burst) Up to 170 bits Receiver ≥ -25dB/K at EL = 30º Modulation 32-ary FSK, 20Hz tone spacing User data rate ~36 bits per seconds Message length Up to 800 bits MAN-0077 Honeywell Global Tracking Ltd...
  • Page 30 Digital output (3.3V, 50µA typical) 1 x Open drain output  250mA max. sink current Power Consumption (Typical @ 12V) Sleep 0.5W Receive (including GPS) 2.3W Transmit Power Supply Voltage Voltage range 9.6V to 32V ‘smoothed’ DC MAN-0077 Honeywell Global Tracking Ltd...
  • Page 31: Appendix B - Warranty

    Appendix B – Warranty Honeywell International Inc. ("HII") warrants its products to be free from defects in materials and workmanship and to conform to HII’s published specifications applicable to the products purchased at the time of shipment. This warranty does not cover any HII product which is (i) improperly installed or used; (ii) damaged by accident or negligence, including failure to follow the proper maintenance, service, and cleaning schedule;...
  • Page 32: Appendix C - Declaration Of Conformity

    Appendix C – Declaration of Conformity MAN-0077 Honeywell Global Tracking Ltd...
  • Page 33: Appendix D - Inmarsat Type Approval

    Appendix D – Inmarsat Type Approval MAN-0077 Honeywell Global Tracking Ltd...
  • Page 34: Appendix E - Product Information

    It is essential that the following information be completed at the time of installation/purchase to ensure that any future warranty claims are dealt with as expeditiously as possible. DATE OF PURCHASE: PURCHASED FROM: SAT-IDP ISN: SAT-IDP SERIAL NUMBER: IMPORTANT: Please keep in a safe place for future reference NOTES: MAN-0077 Honeywell Global Tracking Ltd...
  • Page 35 EMS Technologies Canada Ltd. Honeywell Global Tracking CA 400 Maple Grove Rd Ottawa ON K2V 188 CANADA Web: www.gt.honeywell.com...

This manual is also suitable for:

Sat-idpSat-idp-bcSat-idp-sc

Table of Contents