Product description Product description The ADE5300 is a Reader Interface Module (RIM) used as part of an integrated Siemens access control and security solution. It provides an interface between an Advanced Central Controller (AC5100) and up to eight readers/doors. Safety...
Communications FLN RS-485 two wire, half-duplex Reader Interfaces 8 x Wiegand Reader Interfaces, or 1 x Siemens RS-485 Reader Interface for connecting up to eight Readers Lock output 8 x Relay driven 2 A @ 30 V DC Auxiliary output 8 x Open-Collector 100 mA @ 9.7 –...
Weight ADE5300 S24246-A2500-A1 Eight Reader Interface 1.3 kg Scope of delivery 1 x ADE5300 mounted on base plate 1 x accessory bag (resistors for monitored inputs) 1 x installation manual English 1 x installation manual German Siemens AB Security Products...
Mounting instructions Remove the ADE5300 from its carton and discard the packaging material. Place the ADE5300 (base plate) against the surface to which it is to be affixed and mark the location of the mounting holes. We recommend to mount the ADE5300 within a cabinet. Align the ADE5300 base plate with the holes located on the cabinet backplane and proceed to step 3.
Connect each Wiegand reader to the appropriate READER port of the ADE5300, or connect the SIEMENS RS485 readers to the SRB RS485 port. Up to 8 Siemens RS485 readers can be daisy chained (from one reader to another) on the same connection.
Connect the shielding to the housing earth. Insulate the shielding at the input (e.g. door contact), do not connect it. DC: door contact R: terminating resistors each 22 kOhm Fig. 2 Wiring of monitored input FOR: Fire Override Siemens AB Security Products 05.2015...
Connections and LEDs FOR inputs ADE5300 External device Port Remark Fire alarm system Fire alarm system output: input (+ UB) (normal mode) Fire alarm system OK +12 V In case of fire alarm or malfunction Fire alarm system...
Note: Only units that are located at the ends of bus lines should have Link 26 set to on. LK27 RESET (Restart) Reset the ADE5300 retaining the unit’s firmware: Interrupt the power supply to the unit for 1 sec or –...
FLN COM The LED flashes when the ADE5300 is sending data to the AC5100. SRB COM The LED flashes when the ADE5300 is receiving data from an RS485 card reader. RLY (1-8) The Output relays status is displayed as activated with green LEDs.
Unshielded V DC) Copper Polyethylene Programming and firmware download The ADE5300 is programmed using SiPass software, via the AC5100, or using the „FLN Configurator“ application. Please refer to the appropriate User’s Manual for more Information. Siemens AB Security Products 05.2015...