Siemens SIMATIC IFP2200 INOX MT ETH Compact Operating Instructions
Hide thumbs Also See for SIMATIC IFP2200 INOX MT ETH:

Quick Links

IFP2200 INOX MT ETH
SIMATIC
HMI devices
IFP2200 INOX MT ETH
Compact Operating Instructions
Translation of the original instructions
07/2021
A5E42185570-AD
Preface
Overview
Safety instructions and
further information
Installing and connecting
the device
Maintenance and care
Technical specifications
Technical Support
List of abbreviations
1
2
3
4
5
A
B
Table of Contents
loading

Summary of Contents for Siemens SIMATIC IFP2200 INOX MT ETH

  • Page 1 IFP2200 INOX MT ETH Preface Overview Safety instructions and SIMATIC further information Installing and connecting the device HMI devices IFP2200 INOX MT ETH Maintenance and care Technical specifications Compact Operating Instructions Technical Support List of abbreviations Translation of the original instructions 07/2021 A5E42185570-AD...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Preface

    Preface Scope of validity These compact operating instructions apply to the following INOX device: • SIMATIC IFP2200 INOX MT ETH, article number 6AV7485-6BE00-0AA0 The INOX device is based on the following standard device: • SIMATIC IFP2200, article number 6AV7863-4MA20-0AA0 With regard to electronics and interfaces, the device is based on the Ethernet monitor IFP2200 ETH with capacitive multi-touch screen and corresponding functionality.
  • Page 4 System • System • Machining center • One or more machines Device, built-in device, • SIMATIC IFP2200 INOX MT ETH Ethernet monitor Multitouch Ethernet monitor Touch HMI device Device with capacitive multi-touch screen Touch screen Multi-touch screen Touch operation Multitouch Figures This document contains illustrations of the described devices.
  • Page 5: Table Of Contents

    Table of contents Preface ..............................3 Overview ..............................7 Product overview ......................... 7 Scope of delivery ......................... 8 Device configuration ......................8 Interfaces ..........................9 Accessories .......................... 9 Safety instructions and further information ..................10 Intended use ........................10 General safety instructions ....................10 Operating the capacitive multi-touch screen ...............
  • Page 6 Table of contents Technical specifications ........................33 Software license agreements ..................... 33 Certificates and approvals ....................33 Dimension drawings ......................36 5.3.1 Dimension drawing 22" device ................... 36 5.3.2 Dimension drawing 22" clamping frame ................37 Rating plate ........................37 Technical specifications .....................
  • Page 7: Overview

    Overview Product overview The SIMATIC INOX HMI devices with touch screen and glass front are designed for use in the food and beverage industry and the pharmaceutical industry. Features • Scratch-resistant glass surface with hardness 6 on the Mohs hardness scale •...
  • Page 8: Scope Of Delivery

    Overview 1.2 Scope of delivery Scope of delivery The scope of delivery includes: • 1 × device • 1 × accessory pack with the following contents: – 1 mounting gasket – 1 clamping frame – 1 power supply connector – Mounting clips (see section "Mounting the device (Page 22)") •...
  • Page 9: Interfaces

    ⑥ X60 USB Type B Accessories Accessories can be ordered on the Internet at:Expansion components and accessories (http://www.automation.siemens.com/mcms/pc-based-automation/en/industrial- pc/expansion_components_accessories) • For the replacement of the built-in seal or as spare parts for mounting hardware: Service pack, article number 6AV7675-4JE20-0AA0 • Fasteners: "Die-cast aluminum"...
  • Page 10: Safety Instructions And Further Information

    Safety instructions and further information The general safety instructions in the "SIMATIC HMI Industrial Flat Panels IFP, IFP PRO, IFP ETH" operating instructions apply to all devices with a capacitive multi-touch screen and Ethernet monitors. Intended use The SIMATIC INOX HMI device with glass front is designed to be used for high-performance visualization tasks (operator control and monitoring) and in ambient conditions such as those found in the food, beverage, and pharmaceutical industries.
  • Page 11 Safety instructions and further information 2.2 General safety instructions Open equipment and control cabinet WARNING The device constitutes open equipment on the back side The device constitutes open equipment on the back side. This means that you must integrate the device in an enclosure or cabinet where the device is operated via its front side.
  • Page 12: Operating The Capacitive Multi-Touch Screen

    "SIMATIC S7-1500, ET 200MP, ET 200SP, ET 200AL Designing interference-free controllers", section 7 "Lightning protection and overvoltage protection", which is available on the Internet (https://support.industry.siemens.com/cs/ww/en/view/59193566). The following lightning protection element was used during the testing of the Industrial Flat Panel: Dehn BVT AVD 24"...
  • Page 13 Safety instructions and further information 2.3 Operating the capacitive multi-touch screen WARNING Danger of malfunction due to improper execution of gestures on the touch screen If gestures are executed incorrectly on the touch screen with multi-touch function, these gestures may not be recognized or could be recognized incorrectly. The entries made are then not implemented by the device or are implemented incorrectly or in an unintended manner.
  • Page 14: Notes About Usage

    Safety instructions and further information 2.4 Notes about usage Functions of the multi-touch screen General functions • Detection of up to 5 finger touches at a time. • Detection of gestures that are supported by the operating system or the software installed on the device.
  • Page 15 Safety instructions and further information 2.4 Notes about usage Note The device is intended for operation in an SELV/PELV circuit according to IEC/EN 61010-2-201 in a dry environment, which means a dry environment on the rear of the device. You can find additional information in the section "Operating conditions (Page 40)". Industrial applications The HMI device is designed for industrial applications.
  • Page 16: Use In Hazardous Areas

    Safety instructions and further information 2.5 Use in hazardous areas Use with additional measures The HMI device should not be used at the following locations unless additional measures are taken: • In locations with a high degree of ionizing radiation •...
  • Page 17: Installing And Connecting The Device

    Damaged parts A damaged part can cause device malfunctions. Do not install damaged parts. In the case of damaged parts or incomplete delivery, contact your Siemens representative. 3.1.2 Checking the operating conditions Note the following aspects before installing the device: 1.
  • Page 18 Installing and connecting the device 3.1 Preparing for installation NOTICE Damage due to overheating Inclined installation reduces the convection by the device and therefore the maximum permitted ambient temperature for operation. If there is sufficient forced ventilation, the device can also be operated in the inclined mounting position up to the maximum permitted ambient temperature for vertical installation.
  • Page 19: Notes On Installation

    Installing and connecting the device 3.1 Preparing for installation 3.1.4 Notes on installation Mounting cutout The HMI device can be installed in control cabinets (see table for material thickness). No special tools are required for mounting. The HMI device can be operated both in landscape and portrait format with a vertical inclination of up to +/-35°.
  • Page 20: Inserting The Mounting Seal

    Installing and connecting the device 3.2 Inserting the mounting seal Note Ensure that the maximum ambient temperature is not exceeded when mounting the device in a cabinet and especially in a closed enclosure. Inserting the mounting seal To prevent the mounting seal from being inserted in the wrong direction, it has an asymmetric coding tap.
  • Page 21 Installing and connecting the device 3.2 Inserting the mounting seal 2. Carefully place the device on the front panel (interfaces pointing to you), and insert the mounting seal into the stainless steel front panel as shown. Also pay attention to numbers ④...
  • Page 22: Mounting The Device

    Installing and connecting the device 3.3 Mounting the device Mounting the device Requirement • All packaging components and the edge protection tape, if present, have been removed. • 1 clamping frame • 1 torque wrench for 1.3 Nm with 2.5 mm with hex socket insert. •...
  • Page 23 Installing and connecting the device 3.3 Mounting the device Similar to figure 1. Working from the front, insert the device with inserted mounting seal into the mounting cut-out. 2. Place the clamping frame from the rear on the stainless steel front of the device. 3.
  • Page 24 Installing and connecting the device 3.3 Mounting the device 6. Tighten the setscrews of the opposite (diagonal) corner mounting clips: – Torque wrench, tightening torque 1.3 Nm – Order of action: ③-④-⑤-⑥ 7. Continue in the same way with the top and bottom row from the outside in and on the opposite (diagonal) end.
  • Page 25: Connecting The Device

    Installing and connecting the device 3.4 Connecting the device Connecting the device The specifications in the operating instructions "Industrial Flat Panel IFP1500, IFP1900, IFP2200, IFP1900 PRO, IFP1900 ETH, IFP2200 ETH" apply. Refer to the section "Connecting a DC power supply" for information on connecting the power supply. You can operate the device with the following voltage: •...
  • Page 26: Securing Cables For Use In Hazardous Areas

    Installing and connecting the device 3.4 Connecting the device 3.4.2 Securing cables for use in hazardous areas When devices with Ex approval are used in hazardous areas, note that the connectors must be secured in a captive manner at the interfaces. WARNING Explosion hazard from sparks when connectors come loose If a plug connector comes loose from the associated device interface during operation in a...
  • Page 27: Maintenance And Care

    Maintenance and care Cleaning and maintenance Scope of maintenance The HMI device is designed for maintenance-free operation. Proper handling and regular cleaning will extend the service life of the front operating panel. The front operating panel consists of: • Stainless steel frame •...
  • Page 28 Maintenance and care 4.1 Cleaning and maintenance We recommend cleaning the touch operator panel regularly, depending on the requirements of the user regarding cleanliness. • After a maximum of 8 hours of continuous use. The operator panel should definitely be cleaned when there is a visible contamination.
  • Page 29: Working With Pressure Washers

    Maintenance and care 4.2 Working with pressure washers Cleaning interval for cross contamination If there is a chance that operation may result in cross contamination (e.g. hand contact with product), you should proceed as follows: • Remove visible buildup immediately. •...
  • Page 30: Working With Stainless Steel Surfaces

    Maintenance and care 4.3 Working with stainless steel surfaces NOTICE Observe the ambient conditions During cleaning work, observe the permissible ambient conditions, especially the temperature in operation. We recommend the following cleaning temperatures: • Slight soiling: 30-50 °C • Protein-containing soiling: max. 60 °C The HMI device may be damaged if the pressure is too high or concentrated at a singe point.
  • Page 31: Clean Screen For Touch Hmi Devices

    Maintenance and care 4.4 Clean screen for Touch HMI devices Clean screen for Touch HMI devices The touch screen of the HMI device can be cleaned when it is switched on and a project is running. An operating element must be available in the project that can be used to call the "clean"...
  • Page 32: Calibrate Touch Screen

    "Safety instructions"). The front panel and mounting gasket have been tested for resistance to various chemicals. You can find the list of substances against which the front panel has been tested on the Internet (https://support.industry.siemens.com/cs/ww/en/view/39718396) under Customer Support – FAQ. NOTICE...
  • Page 33: Technical Specifications

    Microsoft licenses License fees for the pre-installed Microsoft operating system on the HMI devices are paid directly by Siemens to the Microsoft company. No COA label ("Certificate of Authenticity") and no other proof of license is required for the HMI device.
  • Page 34 DE-90766 Fürth, Germany You can download information on the EC Declaration of Conformity, here under the keyword "Declaration of Conformity": IFP certificates (https://support.industry.siemens.com/cs/ww/en/ps/16788/cert) Special approvals DGUV approval This device has been tested according to test basis GS-NV 6:2017/09 Testing principles for hygiene: •...
  • Page 35 You can find more information about explosion protection, EC/EU declarations of conformity and other certificates on the Internet at the following address: Certificates for Flat Panels (https://support.industry.siemens.com/cs/ww/en/ps/24423/cert) ATEX approval For an HMI device with "Ex" marking, the following approvals apply according to the following standards.
  • Page 36: Dimension Drawings

    Technical specifications 5.3 Dimension drawings KOREA This product meets the requirements of Korean certification. This product satisfies the requirement of the Korean Certification (KC Mark). 이 기기는 업무용(A급) 전자파 적합기기로서 판매자 또는 사용자는 이 점을 주의하시기 바라며 가정 외의 지역에서 사용하는 것을 목적으로 합니다. Note that this device conforms to Limit Class A for emission of radio interference.
  • Page 37: Dimension Drawing 22" Clamping Frame

    Technical specifications 5.4 Rating plate 5.3.2 Dimension drawing 22" clamping frame Clamping frame All dimensions in mm Rating plate The rating plate includes information that clearly identifies your device. You need this information when you contact Customer Support. The figure below shows an example of a rating plate. ①...
  • Page 38: Technical Specifications

    Technical specifications 5.5 Technical specifications Technical specifications Weight Device Weight including clamping frame, gasket and mounting clips, without packaging IFP2200 INOX MT ETH approx. 8 kg Display IFP2200 MT ETH Type Glass front Resolution 1920 × 1080 pixels (Full HD) Backlighting Half Brightness Life Time (MTBF 50000 h...
  • Page 39: Ambient Conditions

    Technical specifications 5.6 Ambient conditions Ambient conditions 5.6.1 Transport and storage conditions Proper transport and storage, installation and assembly as well as careful operation and maintenance are prerequisites for trouble-free and safe operation of the device. Non-compliance with these regulations shall render the device warranty void. Mechanical transport and storage conditions The following information is for a device that is transported and stored in its original packaging.
  • Page 40: Operating Conditions

    Technical specifications 5.6 Ambient conditions 5.6.2 Operating conditions Mechanical and climatic conditions of use The device is designed for use in locations protected from the effects of the weather. The conditions of use meet the requirements for DIN IEC 60721-3-3: •...
  • Page 41: Electromagnetic Compatibility

    Powerful single pulse (surge) according to IEC 61000-4-5, external protective circuit is required (see function manual "SIMATIC S7-1500, ET 200MP, ET 200SP, ET 200AL Designing interference-free con- trollers", section 7 "Lightning protection and overvoltage protection") on the Internet (https://support.industry.siemens.com/cs/ww/en/view/59193566). Asymmetrical coupling 2 kV power supply cable DC voltage with protective elements 2 kV signal/data cable, >...
  • Page 42 Technical specifications 5.6 Ambient conditions Sinusoidal interference The following table shows the EMC behavior of the modules with respect to sinusoidal interference. This requires the HMI device to meet the specifications and directives for electrical installation. Sinusoidal interference Test values Degree of se- verity HF radiation (electromag-...
  • Page 43: Information On Insulation Tests, Protection Class And Degree Of Protection

    Technical specifications 5.6 Ambient conditions 5.6.4 Information on insulation tests, protection class and degree of protection Test voltages Insulation strength is demonstrated in the type test with the following test voltages in accordance with IEC 61131-2: Circuit Insulation tested with (type test) Rated voltage U 24 V 707 V DC or 500 V AC to other circuits / to ground...
  • Page 44: Technical Support

    You can find additional information and support for the products described on the Internet at the following addresses: • Technical support (https://support.industry.siemens.com/cs/us/en/) • Support request form (https://www.siemens.com/automation/support-request) • After Sales Information System SIMATIC IPC/PG (https://www.siemens.com/asis) • SIMATIC Documentation Collection (https://www.siemens.com/simatic-tech-doku-portal) • Your local representative (https://www.automation.siemens.com/aspa_app) • Training center (https://siemens.com/sitrain) •...
  • Page 45: List Of Abbreviations

    List of abbreviations Direct Current Components and modules endangered by electrostatic discharge Electromagnetic Compatibility European standard Food and Drug Administration Ground High Frequency International Electronic Commission Internet Protocol Light Emitting Diode Thin Film Transistor Underwriter’s Laboratory Universal Serial Bus IFP2200 INOX MT ETH Compact Operating Instructions, 07/2021, A5E42185570-AD...
  • Page 46: Index

    Index Display Technical specifications, 38 Disposal, 32 Disturbance Ambient conditions Pulse-shaped, 41 Climatic, 41 Sinusoidal, 42 Mechanical, 40 Test, 40 Application, 45 Intended, (->intended use) Approval, 33 EAC, 36 EAC, 36 Earth connection, 12 EC Declaration of Conformity, 34 Approvals, 34 Area of application, (?->Use) Edge grouting, 27 Article number, (->Scope of validity)
  • Page 47 Index Mechanical Safety instruction Transport and storage conditions, 39 Operation indoors, 14 Mounting, (Intended) Preventing inadvertent operation, 31 Horizontal mounting, 18 Storage, 39 Vertical, 18 Transportation, 39 Mounting clamp, (->Mounting clip) Unintentional response, 31 Mounting cutout, 19 Scope of maintenance, 27 Dimensions, 19 Scope of validity, 3 Seal, (->Mounting gasket)

This manual is also suitable for:

6av7485-6be00-0aa0

Table of Contents