Husqvarna DXR 140 Quick Start Manual

Sb, pulse transformer loosens
Hide thumbs Also See for DXR 140:

Quick Links

SB, Pulse transformer loosens, DXR 140, 250,
270, 300 & 310, 2014-11
SYMPTOM/DESCRIPTION
It has come to our attention that the Pulse transformer (400VAC =>24VDC) can vibrate loose from
its two mounting brackets (fixed by four torx screws) and thereby cause machine downtime.
Typical symptoms:
• Blown fuses, incoming power (400VAC shortage).
• Blown fuses, F1 fuse rack inside electrical cabinet (400VAC).
• Machine stops suddenly during work, (24VDC shortage).
AFFECTED AREA
DXR 140
DXR 2xx/3xx
B1400033
English 1 (2)
loading

Summary of Contents for Husqvarna DXR 140

  • Page 1 B1400033 English 1 (2) SB, Pulse transformer loosens, DXR 140, 250, 270, 300 & 310, 2014-11 SYMPTOM/DESCRIPTION It has come to our attention that the Pulse transformer (400VAC =>24VDC) can vibrate loose from its two mounting brackets (fixed by four torx screws) and thereby cause machine downtime.
  • Page 2 • A customer complaint is noted related to described symptom/description. • Any given occasion. Strive to be pro-active! PROCEDURE Tools required: T-handle Allen key 3mm (min length160mm) & small scale torque wrench. Remove the Pulse transformer according to the DXR 140/2xx/3xx workshop manual. PARTS INFORMATION Article # Quantity Name...

This manual is also suitable for:

Dxr 250Dxr 270Dxr 300Dxr 310Dxr 2014-11