A800
FR-A860 (600V CLASS SPECIFICATION INVERTER)
INSTRUCTION MANUAL (STARTUP)
FR-A860-00027-00450-N6
FR-A860-00680-04420
Thank you for choosing this Mitsubishi Electric Inverter.
This Instruction Manual and the enclosed CD-ROM give handling information and precautions for use of this
product.
Do not use this product until you have a full knowledge of the equipment, safety information and instructions.
Please forward this Instruction Manual and the enclosed CD-ROM to the end user.
1
INVERTER INSTALLATION AND PRECAUTIONS ...................................................... 5
2
WIRING........................................................................................................................... 6
3
FAILSAFE SYSTEM WHICH USES THE INVERTER ................................................... 8
4
PRECAUTIONS FOR USE OF THE INVERTER ........................................................... 8
5
INVERTER FUNCTION SETTING................................................................................ 10
─CONTENTS─
800
loading

Summary of Contents for Mitsubishi Electric 800 Series

  • Page 1: Table Of Contents

    INSTRUCTION MANUAL (STARTUP) FR-A860-00027-00450-N6 FR-A860-00680-04420 Thank you for choosing this Mitsubishi Electric Inverter. This Instruction Manual and the enclosed CD-ROM give handling information and precautions for use of this product. Do not use this product until you have a full knowledge of the equipment, safety information and instructions.
  • Page 2 This Instruction Manual provides handling information and  Injury Prevention precautions for use of the equipment. CAUTION Please forward this Instruction Manual to the end user.  The voltage applied to each terminal must be the ones specified in the Safety Instructions Instruction Manual (Detailed).
  • Page 3 Application of caution labels WARNING Caution labels are used to ensure safety during use of Mitsubishi Electric inverters. Usage Apply the following labels to the inverter if the "retry function" and/or  Stay away from the equipment when the retry function is set as it will "automatic restart after instantaneous power failure"...
  • Page 4 MEMO...
  • Page 5: Inverter Installation And Precautions

    INVERTER INSTALLATION AND PRECAUTIONS  Inverter model • FR-A860-00450 or lower FR - A8 0 00320 -1 -N6 Symbol Voltage class Symbol Description Circuit board coating UL Type 1 Symbol Plated conductor (conforming to IEC60721-3-3 3C2/3S2) certification 600 V class 00027 to 00450 Inverter SLD rated current (A) With Without...
  • Page 6: Wiring

    Terminal connection diagrams WIRING Terminal connection diagrams FR-A860-00320 Brake resistor  ∗7,∗8 DC reactor ∗1 Brake resistor ∗8 DC reactor ∗1 Sink logic Main circuit terminal Control circuit terminal Jumper Earth Jumper (Ground) Earth (Ground) MCCB R/L1 Inrush current Three-phase Motor S/L2 limit circuit AC power T/L3...
  • Page 7 Main circuit terminals Main circuit terminals  Cable gauge of main circuit terminals and earth (ground) terminals Use an appropriate cable gauge to suppress the voltage drop to 2% or less. If the wiring distance is long between the inverter and motor, the voltage drop in the main circuit will cause the motor torque to decrease especially at a low speed. The following table indicates a selection example for the wiring length of 20 m.
  • Page 8: Failsafe System Which Uses The Inverter

    When a fault is detected by the protective function, the protective function is activated and output a Fault (ALM) signal. However, a fault signal may not be output at an inverter's fault occurrence when the detection circuit or output circuit fails, etc. Although Mitsubishi Electric assures the best quality products, provide an interlock which uses inverter status output signals to prevent accidents such as damage to the machine when the inverter fails for some reason.
  • Page 9 • Electrical corrosion of the bearing When a motor is driven by the inverter, axial voltage is generated on the motor bearing, which may cause electrical corrosion of the bearing in rare cases depending on: condition of the grease used for the bearing, wiring, load, operating conditions of the motor, or specific inverter settings (high carrier frequency).
  • Page 10: Inverter Function Setting

    Operation panel (FR-LU08) INVERTER FUNCTION SETTING Operation panel (FR-LU08) The operation panel can be used for setting the inverter parameters, monitoring various items, and checking fault indications.  Removal and installation of the accessory cover • Loosen the two fixing screws on the accessory cover. •...
  • Page 11 Parameter list Parameter list For simple variable-speed operation of the inverter, the initial values of the parameters may be used as they are. Set the necessary parameters to meet the load and operational specifications. Parameter setting, change and check can be performed from the operation panel. Setting Initial Setting...
  • Page 12 Parameter list Setting Initial Setting Initial Setting Initial Name Name Name range value range value range value PID upper limit 0 to 100%, 9999 9999 RH terminal function High-speed setting 0 to 400% selection maximum current PID lower limit 0 to 100%, 9999 9999 RT terminal function Middle-speed setting PID action set point...
  • Page 13 Parameter list Setting Initial Setting Initial Setting Initial Name Name Name range value range value range value Communication Position feed forward gain 0 to 100% First target position operation command 0, 1 lower 4 digits Position command source acceleration/ First target position upper 0 to 50s Communication speed deceleration time...
  • Page 14 Parameter list Setting Initial Setting Initial Setting Initial Name Name Name range value range value range value 100, 111, 112, Reverse rotation Maximum motor 0 to 400Hz, 9999 121 to 124, 200, excitation current low- 0 to 300%, 9999 9999 frequency 9999 211, 212, 221 to...
  • Page 15 Parameter list Setting Initial Setting Initial Setting Initial Name Name Name range value range value range value Torque command 0 to 500A, Terminal 1 gain 0 to 6 0 to 590Hz 60Hz Second motor torque source selection 9999 frequency (speed) ...
  • Page 16 Parameter list Setting Initial Setting Initial Setting Initial Name Name Name range value range value range value 1025 Trigger mode selection 0 to 4 Second output Tenth positioning 0 to 3600s, 1259 0.01 to 360s 1147 interruption detection deceleration time Number of sampling 9999 1026...
  • Page 17 Parameter list Setting Initial Name range value Starting times upper 4 1411 0 to 9999 digits Motor induced voltage 1412 constant (phi f) 0 to 2, 9999 9999 exponent Second motor induced 1413 voltage constant (phi f) 0 to 2, 9999 9999 exponent Load characteristics...
  • Page 18 Appendix Appendix 1 Instructions for UL and cUL (Standard to comply with: UL 508C, CSA C22.2 No.274-13)  General precaution CAUTION - Risk of Electric Shock - The bus capacitor discharge time is 10 minutes. Before starting wiring or inspection, switch power off, wait for more than 10 minutes, and check for residual voltage between terminal P/+ and N/- with a meter etc., to avoid a hazard of electrical shock.
  • Page 19 Appendix 2 Restricted Use of Hazardous Substances in Electronic and Electrical Products The mark of restricted use of hazardous substances in electronic and electrical products is applied to the product as follows based on the “Management Methods for the Restriction of the Use of Hazardous Substances in Electrical and Electronic Products” of the People's Republic of China. 电器电子产品有害物质限制使用标识要求...
  • Page 20 MEMO...
  • Page 21 4. Exclusion of loss in opportunity and secondary loss from warranty liability Regardless of the gratis warranty term, Mitsubishi Electric shall not be liable for compensation to: Damages caused by any cause found not to be the responsibility of Mitsubishi Electric.
  • Page 22 • The copyright and other rights of the enclosed CD-ROM all belong to Mitsubishi Electric Corporation. • No part of the enclosed CD-ROM may be copied or reproduced without the permission of Mitsubishi Electric Corporation. • Specifications of the enclosed CD-ROM are subject to change for modification without notice.
  • Page 23 REVISIONS *The manual number is given on the bottom left of the back cover. Revision Date *Manual Number Revision Nov. 2014 IB-0600562ENG-A First edition Jan. 2015 IB-0600562ENG-B Added • FR-A860-00027 to 00170 May 2015 IB-0600562ENG-C Added • Location change of earth (ground) terminals for the FR-A860-00027 to 00170 Oct.
  • Page 24 FR-A800/A800 Plus Series Instruction Manual Supplement Internal storage device fault (E.PE6) The operation of the storage device in the inverter can be checked. If a data fault occurs in the storage device in the inverter, the protective function (E.PE6) is activated. When the read value of Pr.890 is "7"...
  • Page 25 GR-18542 Piraeus SE- 223 55 Lund Phone: +30 (0)211 / 1206-900 Phone: +46 (0) 8 625 10 00 Fax: +30 (0)211 / 1206-999 Mitsubishi Electric Turkey Elektrik Ürünleri A.Ş. TURKEY MELTRADE Kft. HUNGARY Fabrika Otomasyonu Merkezi Fertő utca 14. Şerifali Mahallesi Nutuk Sokak No.5 HU-1107 Budapest TR-34775 Ümraniye-İSTANBUL...